Cargando…

Evaluation of noise hazard during the holmium laser enucleation of prostate

BACKGROUND: To evaluate noise hazard during holmium laser enucleation of the prostate (HoLEP), we designed a study to detect such a risk in this procedure. METHODS: This study was conducted over a 12-month period on 223 patients with benign prostatic hyperplasia (BPH), 121 of whom underwent HoLEP wh...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Huan, Chen, Yan-bo, Gu, Meng, Chen, Qi, Wang, Zhong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5577658/
https://www.ncbi.nlm.nih.gov/pubmed/28859618
http://dx.doi.org/10.1186/s12894-017-0246-y
_version_ 1783260383638716416
author Xu, Huan
Chen, Yan-bo
Gu, Meng
Chen, Qi
Wang, Zhong
author_facet Xu, Huan
Chen, Yan-bo
Gu, Meng
Chen, Qi
Wang, Zhong
author_sort Xu, Huan
collection PubMed
description BACKGROUND: To evaluate noise hazard during holmium laser enucleation of the prostate (HoLEP), we designed a study to detect such a risk in this procedure. METHODS: This study was conducted over a 12-month period on 223 patients with benign prostatic hyperplasia (BPH), 121 of whom underwent HoLEP while those remaining underwent transurethral resection of the prostate (TURP). A sound level meter was used to detect the exposure of surgeons to noise. The recordings used were in accordance with the standards set by the Occupational Safety and Health Administration (OSHA) and the United States Environmental Protection Agency. Moreover, each of the 43 surgeons participating in a BPH discussion conference answered the questionnaire on the influence of noise, and 33 surgeons in our department volunteered for blood pressure monitoring post-surgically. RESULTS: The sound level produced by a high-powered holmium laser emitter during HoLEP was 67.37 ± 0.13 dB, which was significantly higher than the sound heard during TURP (46.41 ± 0.29 dB, P < 0.01). The 65–70 dB noise during HoLEP was proved to be a safe level in accordance with the OSHA standards. However, this level was considerably greater than the stated 55 dB. Moreover, it exceeded the normal communication protective level of 60 dB. In the analysis of responses from the surgeons, the HoLEP group obtained an average score that reflected disturbance caused by the laser emitter and an increase in average systolic pressure relative to that in the TURP group. CONCLUSIONS: The noise level during HoLEP is within hearing conservation levels. However, the noise disturbs intrateam communication and concentration during surgery. Some surgeons may experience discomfort post-surgically, but no significant difference among the groups is indicated. The findings suggest that measures should be taken to address the noise caused by the laser emitter during HoLEP.
format Online
Article
Text
id pubmed-5577658
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-55776582017-08-31 Evaluation of noise hazard during the holmium laser enucleation of prostate Xu, Huan Chen, Yan-bo Gu, Meng Chen, Qi Wang, Zhong BMC Urol Research Article BACKGROUND: To evaluate noise hazard during holmium laser enucleation of the prostate (HoLEP), we designed a study to detect such a risk in this procedure. METHODS: This study was conducted over a 12-month period on 223 patients with benign prostatic hyperplasia (BPH), 121 of whom underwent HoLEP while those remaining underwent transurethral resection of the prostate (TURP). A sound level meter was used to detect the exposure of surgeons to noise. The recordings used were in accordance with the standards set by the Occupational Safety and Health Administration (OSHA) and the United States Environmental Protection Agency. Moreover, each of the 43 surgeons participating in a BPH discussion conference answered the questionnaire on the influence of noise, and 33 surgeons in our department volunteered for blood pressure monitoring post-surgically. RESULTS: The sound level produced by a high-powered holmium laser emitter during HoLEP was 67.37 ± 0.13 dB, which was significantly higher than the sound heard during TURP (46.41 ± 0.29 dB, P < 0.01). The 65–70 dB noise during HoLEP was proved to be a safe level in accordance with the OSHA standards. However, this level was considerably greater than the stated 55 dB. Moreover, it exceeded the normal communication protective level of 60 dB. In the analysis of responses from the surgeons, the HoLEP group obtained an average score that reflected disturbance caused by the laser emitter and an increase in average systolic pressure relative to that in the TURP group. CONCLUSIONS: The noise level during HoLEP is within hearing conservation levels. However, the noise disturbs intrateam communication and concentration during surgery. Some surgeons may experience discomfort post-surgically, but no significant difference among the groups is indicated. The findings suggest that measures should be taken to address the noise caused by the laser emitter during HoLEP. BioMed Central 2017-08-31 /pmc/articles/PMC5577658/ /pubmed/28859618 http://dx.doi.org/10.1186/s12894-017-0246-y Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Xu, Huan
Chen, Yan-bo
Gu, Meng
Chen, Qi
Wang, Zhong
Evaluation of noise hazard during the holmium laser enucleation of prostate
title Evaluation of noise hazard during the holmium laser enucleation of prostate
title_full Evaluation of noise hazard during the holmium laser enucleation of prostate
title_fullStr Evaluation of noise hazard during the holmium laser enucleation of prostate
title_full_unstemmed Evaluation of noise hazard during the holmium laser enucleation of prostate
title_short Evaluation of noise hazard during the holmium laser enucleation of prostate
title_sort evaluation of noise hazard during the holmium laser enucleation of prostate
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5577658/
https://www.ncbi.nlm.nih.gov/pubmed/28859618
http://dx.doi.org/10.1186/s12894-017-0246-y
work_keys_str_mv AT xuhuan evaluationofnoisehazardduringtheholmiumlaserenucleationofprostate
AT chenyanbo evaluationofnoisehazardduringtheholmiumlaserenucleationofprostate
AT gumeng evaluationofnoisehazardduringtheholmiumlaserenucleationofprostate
AT chenqi evaluationofnoisehazardduringtheholmiumlaserenucleationofprostate
AT wangzhong evaluationofnoisehazardduringtheholmiumlaserenucleationofprostate