Cargando…

Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration

Radiometric cross-calibration between the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and the Terra-Moderate Resolution Imaging Spectroradiometer (MODIS) has been partially used to derive the ASTER radiometric calibration coefficient (RCC) curve as a function of date on vi...

Descripción completa

Detalles Bibliográficos
Autores principales: Obata, Kenta, Tsuchida, Satoshi, Yamamoto, Hirokazu, Thome, Kurtis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579527/
https://www.ncbi.nlm.nih.gov/pubmed/28777329
http://dx.doi.org/10.3390/s17081793
_version_ 1783260721732124672
author Obata, Kenta
Tsuchida, Satoshi
Yamamoto, Hirokazu
Thome, Kurtis
author_facet Obata, Kenta
Tsuchida, Satoshi
Yamamoto, Hirokazu
Thome, Kurtis
author_sort Obata, Kenta
collection PubMed
description Radiometric cross-calibration between the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and the Terra-Moderate Resolution Imaging Spectroradiometer (MODIS) has been partially used to derive the ASTER radiometric calibration coefficient (RCC) curve as a function of date on visible to near-infrared bands. However, cross-calibration is not sufficiently accurate, since the effects of the differences in the sensor’s spectral and spatial responses are not fully mitigated. The present study attempts to evaluate radiometric consistency across two sensors using an improved cross-calibration algorithm to address the spectral and spatial effects and derive cross-calibration-based RCCs, which increases the ASTER calibration accuracy. Overall, radiances measured with ASTER bands 1 and 2 are on averages 3.9% and 3.6% greater than the ones measured on the same scene with their MODIS counterparts and ASTER band 3N (nadir) is 0.6% smaller than its MODIS counterpart in current radiance/reflectance products. The percentage root mean squared errors (%RMSEs) between the radiances of two sensors are 3.7, 4.2, and 2.3 for ASTER band 1, 2, and 3N, respectively, which are slightly greater or smaller than the required ASTER radiometric calibration accuracy (4%). The uncertainty of the cross-calibration is analyzed by elaborating the error budget table to evaluate the International System of Units (SI)-traceability of the results. The use of the derived RCCs will allow further reduction of errors in ASTER radiometric calibration and subsequently improve interoperability across sensors for synergistic applications.
format Online
Article
Text
id pubmed-5579527
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-55795272017-09-06 Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration Obata, Kenta Tsuchida, Satoshi Yamamoto, Hirokazu Thome, Kurtis Sensors (Basel) Article Radiometric cross-calibration between the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and the Terra-Moderate Resolution Imaging Spectroradiometer (MODIS) has been partially used to derive the ASTER radiometric calibration coefficient (RCC) curve as a function of date on visible to near-infrared bands. However, cross-calibration is not sufficiently accurate, since the effects of the differences in the sensor’s spectral and spatial responses are not fully mitigated. The present study attempts to evaluate radiometric consistency across two sensors using an improved cross-calibration algorithm to address the spectral and spatial effects and derive cross-calibration-based RCCs, which increases the ASTER calibration accuracy. Overall, radiances measured with ASTER bands 1 and 2 are on averages 3.9% and 3.6% greater than the ones measured on the same scene with their MODIS counterparts and ASTER band 3N (nadir) is 0.6% smaller than its MODIS counterpart in current radiance/reflectance products. The percentage root mean squared errors (%RMSEs) between the radiances of two sensors are 3.7, 4.2, and 2.3 for ASTER band 1, 2, and 3N, respectively, which are slightly greater or smaller than the required ASTER radiometric calibration accuracy (4%). The uncertainty of the cross-calibration is analyzed by elaborating the error budget table to evaluate the International System of Units (SI)-traceability of the results. The use of the derived RCCs will allow further reduction of errors in ASTER radiometric calibration and subsequently improve interoperability across sensors for synergistic applications. MDPI 2017-08-04 /pmc/articles/PMC5579527/ /pubmed/28777329 http://dx.doi.org/10.3390/s17081793 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Obata, Kenta
Tsuchida, Satoshi
Yamamoto, Hirokazu
Thome, Kurtis
Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration
title Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration
title_full Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration
title_fullStr Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration
title_full_unstemmed Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration
title_short Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration
title_sort cross-calibration between aster and modis visible to near-infrared bands for improvement of aster radiometric calibration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579527/
https://www.ncbi.nlm.nih.gov/pubmed/28777329
http://dx.doi.org/10.3390/s17081793
work_keys_str_mv AT obatakenta crosscalibrationbetweenasterandmodisvisibletonearinfraredbandsforimprovementofasterradiometriccalibration
AT tsuchidasatoshi crosscalibrationbetweenasterandmodisvisibletonearinfraredbandsforimprovementofasterradiometriccalibration
AT yamamotohirokazu crosscalibrationbetweenasterandmodisvisibletonearinfraredbandsforimprovementofasterradiometriccalibration
AT thomekurtis crosscalibrationbetweenasterandmodisvisibletonearinfraredbandsforimprovementofasterradiometriccalibration