Cargando…

Effects of topical flurbiprofen sodium, diclofenac sodium, ketorolac tromethamine and benzalkonium chloride on corneal sensitivity in normal dogs

To evaluate corneal sensitivity by using the Cochet-Bonnet® esthesiometer in normal canine eyes at different time points following instillation of three different topical non-steroidal anti-inflammatory drugs (flurbiprofen sodium 0.03%, diclofenac sodium 0.1% and ketorolac tromethamine 0.5%) and ben...

Descripción completa

Detalles Bibliográficos
Autores principales: Cantarella, Raquel de Araújo, de Oliveira, Juliana Kravetz, Dorbandt, Daniel M., Montiani-Ferreira, Fabiano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculty of Veterinary Medicine, University of Tripoli and Libyan Authority for Research, Science and Technology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579566/
https://www.ncbi.nlm.nih.gov/pubmed/28884078
http://dx.doi.org/10.4314/ovj.v7i3.9
Descripción
Sumario:To evaluate corneal sensitivity by using the Cochet-Bonnet® esthesiometer in normal canine eyes at different time points following instillation of three different topical non-steroidal anti-inflammatory drugs (flurbiprofen sodium 0.03%, diclofenac sodium 0.1% and ketorolac tromethamine 0.5%) and benzalkonium chloride 0.01%. Six healthy mixed breed dogs from the same litter were used in two different stages. First, one drop of flurbiprofen sodium 0.03% and diclofenac sodium 0.1% in each eye; second, one drop of ketorolac tromethamine 0.5% and benzalkonium chloride 0.01% in each eye. Baseline esthesiometry was obtained before eye drop application and every 15 minutes thereafter until a total of 105 minutes of evaluation time. A one-week interval was allowed between the two treatment phases. Statistical analysis was used to compare means according to time of evaluation and drug used. Diclofenac sodium 0.1% decreased corneal sensitivity at 75 and 90 minutes (P > 0.015) with possible interference on neuronal nociceptive activity and analgesic effect while ketorolac tromethamine 0.5% did not show any variation for esthesiometry means along the evaluation. Flurbiprofen sodium 0.03% resulted in increased esthesiometry values 30 minutes after instillation (P > 0.013), increasing corneal sensitivity and possibly producing a greater irritant corneal effect over its analgesic properties. Benzalkonium chloride 0.01% significantly increased corneal sensitivity at 15 minutes of evaluation (P > 0.001), most likely resulting from its irritating effect. Esthesiometry did not allow a definite conclusion over the analgesic effect of the NSAIDs tested; however it was effective in detecting fluctuations in corneal sensitivity.