Cargando…
Portable Multispectral Colorimeter for Metallic Ion Detection and Classification
This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was develo...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579749/ https://www.ncbi.nlm.nih.gov/pubmed/28788082 http://dx.doi.org/10.3390/s17081730 |
_version_ | 1783260772749541376 |
---|---|
author | Braga, Mauro S. Jaimes, Ruth F. V. V. Borysow, Walter Gomes, Osmar F. Salcedo, Walter J. |
author_facet | Braga, Mauro S. Jaimes, Ruth F. V. V. Borysow, Walter Gomes, Osmar F. Salcedo, Walter J. |
author_sort | Braga, Mauro S. |
collection | PubMed |
description | This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using optoelectronic multispectral sensors was fully integrated in the embedded hardware FPGA ( Field Programmable Gate Array) technology and software based on virtual instrumentation (NI LabView(®)). The system draws on an indicative colorimeter by using the chromogen reagent of 1-(2-pyridylazo)-2-naphthol (PAN). The results obtained with the signal processing and pattern analysis using the method of the linear discriminant analysis, allows excellent results during detection and classification of Pb(II), Cd(II), Zn(II), Cu(II), Fe(III) and Ni(II) ions, with almost the same level of performance as for those obtained from the Ultravioled and visible (UV-VIS) spectrophotometers of high spectral resolution. |
format | Online Article Text |
id | pubmed-5579749 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-55797492017-09-06 Portable Multispectral Colorimeter for Metallic Ion Detection and Classification Braga, Mauro S. Jaimes, Ruth F. V. V. Borysow, Walter Gomes, Osmar F. Salcedo, Walter J. Sensors (Basel) Article This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using optoelectronic multispectral sensors was fully integrated in the embedded hardware FPGA ( Field Programmable Gate Array) technology and software based on virtual instrumentation (NI LabView(®)). The system draws on an indicative colorimeter by using the chromogen reagent of 1-(2-pyridylazo)-2-naphthol (PAN). The results obtained with the signal processing and pattern analysis using the method of the linear discriminant analysis, allows excellent results during detection and classification of Pb(II), Cd(II), Zn(II), Cu(II), Fe(III) and Ni(II) ions, with almost the same level of performance as for those obtained from the Ultravioled and visible (UV-VIS) spectrophotometers of high spectral resolution. MDPI 2017-07-28 /pmc/articles/PMC5579749/ /pubmed/28788082 http://dx.doi.org/10.3390/s17081730 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Braga, Mauro S. Jaimes, Ruth F. V. V. Borysow, Walter Gomes, Osmar F. Salcedo, Walter J. Portable Multispectral Colorimeter for Metallic Ion Detection and Classification |
title | Portable Multispectral Colorimeter for Metallic Ion Detection and Classification |
title_full | Portable Multispectral Colorimeter for Metallic Ion Detection and Classification |
title_fullStr | Portable Multispectral Colorimeter for Metallic Ion Detection and Classification |
title_full_unstemmed | Portable Multispectral Colorimeter for Metallic Ion Detection and Classification |
title_short | Portable Multispectral Colorimeter for Metallic Ion Detection and Classification |
title_sort | portable multispectral colorimeter for metallic ion detection and classification |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579749/ https://www.ncbi.nlm.nih.gov/pubmed/28788082 http://dx.doi.org/10.3390/s17081730 |
work_keys_str_mv | AT bragamauros portablemultispectralcolorimeterformetalliciondetectionandclassification AT jaimesruthfvv portablemultispectralcolorimeterformetalliciondetectionandclassification AT borysowwalter portablemultispectralcolorimeterformetalliciondetectionandclassification AT gomesosmarf portablemultispectralcolorimeterformetalliciondetectionandclassification AT salcedowalterj portablemultispectralcolorimeterformetalliciondetectionandclassification |