Cargando…

Sparse Representation Based Frequency Detection and Uncertainty Reduction in Blade Tip Timing Measurement for Multi-Mode Blade Vibration Monitoring

The accurate monitoring of blade vibration under operating conditions is essential in turbo-machinery testing. Blade tip timing (BTT) is a promising non-contact technique for the measurement of blade vibrations. However, the BTT sampling data are inherently under-sampled and contaminated with severa...

Descripción completa

Detalles Bibliográficos
Autores principales: Pan, Minghao, Yang, Yongmin, Guan, Fengjiao, Hu, Haifeng, Xu, Hailong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579762/
https://www.ncbi.nlm.nih.gov/pubmed/28758952
http://dx.doi.org/10.3390/s17081745
_version_ 1783260775614251008
author Pan, Minghao
Yang, Yongmin
Guan, Fengjiao
Hu, Haifeng
Xu, Hailong
author_facet Pan, Minghao
Yang, Yongmin
Guan, Fengjiao
Hu, Haifeng
Xu, Hailong
author_sort Pan, Minghao
collection PubMed
description The accurate monitoring of blade vibration under operating conditions is essential in turbo-machinery testing. Blade tip timing (BTT) is a promising non-contact technique for the measurement of blade vibrations. However, the BTT sampling data are inherently under-sampled and contaminated with several measurement uncertainties. How to recover frequency spectra of blade vibrations though processing these under-sampled biased signals is a bottleneck problem. A novel method of BTT signal processing for alleviating measurement uncertainties in recovery of multi-mode blade vibration frequency spectrum is proposed in this paper. The method can be divided into four phases. First, a single measurement vector model is built by exploiting that the blade vibration signals are sparse in frequency spectra. Secondly, the uniqueness of the nonnegative sparse solution is studied to achieve the vibration frequency spectrum. Thirdly, typical sources of BTT measurement uncertainties are quantitatively analyzed. Finally, an improved vibration frequency spectra recovery method is proposed to get a guaranteed level of sparse solution when measurement results are biased. Simulations and experiments are performed to prove the feasibility of the proposed method. The most outstanding advantage is that this method can prevent the recovered multi-mode vibration spectra from being affected by BTT measurement uncertainties without increasing the probe number.
format Online
Article
Text
id pubmed-5579762
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-55797622017-09-06 Sparse Representation Based Frequency Detection and Uncertainty Reduction in Blade Tip Timing Measurement for Multi-Mode Blade Vibration Monitoring Pan, Minghao Yang, Yongmin Guan, Fengjiao Hu, Haifeng Xu, Hailong Sensors (Basel) Article The accurate monitoring of blade vibration under operating conditions is essential in turbo-machinery testing. Blade tip timing (BTT) is a promising non-contact technique for the measurement of blade vibrations. However, the BTT sampling data are inherently under-sampled and contaminated with several measurement uncertainties. How to recover frequency spectra of blade vibrations though processing these under-sampled biased signals is a bottleneck problem. A novel method of BTT signal processing for alleviating measurement uncertainties in recovery of multi-mode blade vibration frequency spectrum is proposed in this paper. The method can be divided into four phases. First, a single measurement vector model is built by exploiting that the blade vibration signals are sparse in frequency spectra. Secondly, the uniqueness of the nonnegative sparse solution is studied to achieve the vibration frequency spectrum. Thirdly, typical sources of BTT measurement uncertainties are quantitatively analyzed. Finally, an improved vibration frequency spectra recovery method is proposed to get a guaranteed level of sparse solution when measurement results are biased. Simulations and experiments are performed to prove the feasibility of the proposed method. The most outstanding advantage is that this method can prevent the recovered multi-mode vibration spectra from being affected by BTT measurement uncertainties without increasing the probe number. MDPI 2017-07-30 /pmc/articles/PMC5579762/ /pubmed/28758952 http://dx.doi.org/10.3390/s17081745 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pan, Minghao
Yang, Yongmin
Guan, Fengjiao
Hu, Haifeng
Xu, Hailong
Sparse Representation Based Frequency Detection and Uncertainty Reduction in Blade Tip Timing Measurement for Multi-Mode Blade Vibration Monitoring
title Sparse Representation Based Frequency Detection and Uncertainty Reduction in Blade Tip Timing Measurement for Multi-Mode Blade Vibration Monitoring
title_full Sparse Representation Based Frequency Detection and Uncertainty Reduction in Blade Tip Timing Measurement for Multi-Mode Blade Vibration Monitoring
title_fullStr Sparse Representation Based Frequency Detection and Uncertainty Reduction in Blade Tip Timing Measurement for Multi-Mode Blade Vibration Monitoring
title_full_unstemmed Sparse Representation Based Frequency Detection and Uncertainty Reduction in Blade Tip Timing Measurement for Multi-Mode Blade Vibration Monitoring
title_short Sparse Representation Based Frequency Detection and Uncertainty Reduction in Blade Tip Timing Measurement for Multi-Mode Blade Vibration Monitoring
title_sort sparse representation based frequency detection and uncertainty reduction in blade tip timing measurement for multi-mode blade vibration monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579762/
https://www.ncbi.nlm.nih.gov/pubmed/28758952
http://dx.doi.org/10.3390/s17081745
work_keys_str_mv AT panminghao sparserepresentationbasedfrequencydetectionanduncertaintyreductioninbladetiptimingmeasurementformultimodebladevibrationmonitoring
AT yangyongmin sparserepresentationbasedfrequencydetectionanduncertaintyreductioninbladetiptimingmeasurementformultimodebladevibrationmonitoring
AT guanfengjiao sparserepresentationbasedfrequencydetectionanduncertaintyreductioninbladetiptimingmeasurementformultimodebladevibrationmonitoring
AT huhaifeng sparserepresentationbasedfrequencydetectionanduncertaintyreductioninbladetiptimingmeasurementformultimodebladevibrationmonitoring
AT xuhailong sparserepresentationbasedfrequencydetectionanduncertaintyreductioninbladetiptimingmeasurementformultimodebladevibrationmonitoring