Cargando…

Suture Line Dehiscence after Endovascular Aneurysm Repair in a Patient with Marfan Syndrome

A 68-year-old man with Marfan syndrome developed de-novo leakage after endovascular aneurysm repair of a Dacron graft. Findings at subsequent reoperation suggested that the rebound force on the endograft generated by marked longitudinal deformation in the Dacron graft may have placed stress on the s...

Descripción completa

Detalles Bibliográficos
Autores principales: Kasahara, Hirofumi, Haijima, Norimasa, Hachiya, Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579775/
https://www.ncbi.nlm.nih.gov/pubmed/29034043
http://dx.doi.org/10.3400/avd.cr.17-00011
_version_ 1783260778193747968
author Kasahara, Hirofumi
Haijima, Norimasa
Hachiya, Takashi
author_facet Kasahara, Hirofumi
Haijima, Norimasa
Hachiya, Takashi
author_sort Kasahara, Hirofumi
collection PubMed
description A 68-year-old man with Marfan syndrome developed de-novo leakage after endovascular aneurysm repair of a Dacron graft. Findings at subsequent reoperation suggested that the rebound force on the endograft generated by marked longitudinal deformation in the Dacron graft may have placed stress on the suture line, leading to partial dehiscence. The Dacron graft seemed to provide a stable proximal landing zone. However, the strong tendency of some endograft devices to return to their original shape may apply stress that affected weakened regions of the native aorta.
format Online
Article
Text
id pubmed-5579775
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
record_format MEDLINE/PubMed
spelling pubmed-55797752017-10-13 Suture Line Dehiscence after Endovascular Aneurysm Repair in a Patient with Marfan Syndrome Kasahara, Hirofumi Haijima, Norimasa Hachiya, Takashi Ann Vasc Dis Case Report A 68-year-old man with Marfan syndrome developed de-novo leakage after endovascular aneurysm repair of a Dacron graft. Findings at subsequent reoperation suggested that the rebound force on the endograft generated by marked longitudinal deformation in the Dacron graft may have placed stress on the suture line, leading to partial dehiscence. The Dacron graft seemed to provide a stable proximal landing zone. However, the strong tendency of some endograft devices to return to their original shape may apply stress that affected weakened regions of the native aorta. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2017-06-25 /pmc/articles/PMC5579775/ /pubmed/29034043 http://dx.doi.org/10.3400/avd.cr.17-00011 Text en Copyright © 2017 Annals of Vascular Diseases http://creativecommons.org/licenses/by-nc-sa/4.0/ This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original.
spellingShingle Case Report
Kasahara, Hirofumi
Haijima, Norimasa
Hachiya, Takashi
Suture Line Dehiscence after Endovascular Aneurysm Repair in a Patient with Marfan Syndrome
title Suture Line Dehiscence after Endovascular Aneurysm Repair in a Patient with Marfan Syndrome
title_full Suture Line Dehiscence after Endovascular Aneurysm Repair in a Patient with Marfan Syndrome
title_fullStr Suture Line Dehiscence after Endovascular Aneurysm Repair in a Patient with Marfan Syndrome
title_full_unstemmed Suture Line Dehiscence after Endovascular Aneurysm Repair in a Patient with Marfan Syndrome
title_short Suture Line Dehiscence after Endovascular Aneurysm Repair in a Patient with Marfan Syndrome
title_sort suture line dehiscence after endovascular aneurysm repair in a patient with marfan syndrome
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579775/
https://www.ncbi.nlm.nih.gov/pubmed/29034043
http://dx.doi.org/10.3400/avd.cr.17-00011
work_keys_str_mv AT kasaharahirofumi suturelinedehiscenceafterendovascularaneurysmrepairinapatientwithmarfansyndrome
AT haijimanorimasa suturelinedehiscenceafterendovascularaneurysmrepairinapatientwithmarfansyndrome
AT hachiyatakashi suturelinedehiscenceafterendovascularaneurysmrepairinapatientwithmarfansyndrome