Cargando…

The Ultrasonic Directional Tidal Breathing Pattern Sensor: Equitable Design Realization Based on Phase Information

Pulmonary ailments are conventionally diagnosed by spirometry. The complex forceful breathing maneuver as well as the extreme cost of spirometry renders it unsuitable in many situations. This work is aimed to facilitate an emerging direction of tidal breathing-based pulmonary evaluation by designing...

Descripción completa

Detalles Bibliográficos
Autores principales: Sinharay, Arijit, Rakshit, Raj, Khasnobish, Anwesha, Chakravarty, Tapas, Ghosh, Deb, Pal, Arpan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579868/
https://www.ncbi.nlm.nih.gov/pubmed/28800103
http://dx.doi.org/10.3390/s17081853
_version_ 1783260795305459712
author Sinharay, Arijit
Rakshit, Raj
Khasnobish, Anwesha
Chakravarty, Tapas
Ghosh, Deb
Pal, Arpan
author_facet Sinharay, Arijit
Rakshit, Raj
Khasnobish, Anwesha
Chakravarty, Tapas
Ghosh, Deb
Pal, Arpan
author_sort Sinharay, Arijit
collection PubMed
description Pulmonary ailments are conventionally diagnosed by spirometry. The complex forceful breathing maneuver as well as the extreme cost of spirometry renders it unsuitable in many situations. This work is aimed to facilitate an emerging direction of tidal breathing-based pulmonary evaluation by designing a novel, equitable, precise and portable device for acquisition and analysis of directional tidal breathing patterns, in real time. The proposed system primarily uses an in-house designed blow pipe, 40-kHz air-coupled ultrasound transreceivers, and a radio frequency (RF) phase-gain integrated circuit (IC). Moreover, in order to achieve high sensitivity in a cost-effective design philosophy, we have exploited the phase measurement technique, instead of selecting the contemporary time-of-flight (TOF) measurement; since application of the TOF principle in tidal breathing assessments requires sub-micro to nanosecond time resolution. This approach, which depends on accurate phase measurement, contributed to enhanced sensitivity using a simple electronics design. The developed system has been calibrated using a standard 3-L calibration syringe. The parameters of this system are validated against a standard spirometer, with maximum percentage error below 16%. Further, the extracted respiratory parameters related to tidal breathing have been found to be comparable with relevant prior works. The error in detecting respiration rate only is 3.9% compared to manual evaluation. These encouraging insights reveal the definite potential of our tidal breathing pattern (TBP) prototype for measuring tidal breathing parameters in order to extend the reach of affordable healthcare in rural regions and developing areas.
format Online
Article
Text
id pubmed-5579868
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-55798682017-09-06 The Ultrasonic Directional Tidal Breathing Pattern Sensor: Equitable Design Realization Based on Phase Information Sinharay, Arijit Rakshit, Raj Khasnobish, Anwesha Chakravarty, Tapas Ghosh, Deb Pal, Arpan Sensors (Basel) Article Pulmonary ailments are conventionally diagnosed by spirometry. The complex forceful breathing maneuver as well as the extreme cost of spirometry renders it unsuitable in many situations. This work is aimed to facilitate an emerging direction of tidal breathing-based pulmonary evaluation by designing a novel, equitable, precise and portable device for acquisition and analysis of directional tidal breathing patterns, in real time. The proposed system primarily uses an in-house designed blow pipe, 40-kHz air-coupled ultrasound transreceivers, and a radio frequency (RF) phase-gain integrated circuit (IC). Moreover, in order to achieve high sensitivity in a cost-effective design philosophy, we have exploited the phase measurement technique, instead of selecting the contemporary time-of-flight (TOF) measurement; since application of the TOF principle in tidal breathing assessments requires sub-micro to nanosecond time resolution. This approach, which depends on accurate phase measurement, contributed to enhanced sensitivity using a simple electronics design. The developed system has been calibrated using a standard 3-L calibration syringe. The parameters of this system are validated against a standard spirometer, with maximum percentage error below 16%. Further, the extracted respiratory parameters related to tidal breathing have been found to be comparable with relevant prior works. The error in detecting respiration rate only is 3.9% compared to manual evaluation. These encouraging insights reveal the definite potential of our tidal breathing pattern (TBP) prototype for measuring tidal breathing parameters in order to extend the reach of affordable healthcare in rural regions and developing areas. MDPI 2017-08-11 /pmc/articles/PMC5579868/ /pubmed/28800103 http://dx.doi.org/10.3390/s17081853 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sinharay, Arijit
Rakshit, Raj
Khasnobish, Anwesha
Chakravarty, Tapas
Ghosh, Deb
Pal, Arpan
The Ultrasonic Directional Tidal Breathing Pattern Sensor: Equitable Design Realization Based on Phase Information
title The Ultrasonic Directional Tidal Breathing Pattern Sensor: Equitable Design Realization Based on Phase Information
title_full The Ultrasonic Directional Tidal Breathing Pattern Sensor: Equitable Design Realization Based on Phase Information
title_fullStr The Ultrasonic Directional Tidal Breathing Pattern Sensor: Equitable Design Realization Based on Phase Information
title_full_unstemmed The Ultrasonic Directional Tidal Breathing Pattern Sensor: Equitable Design Realization Based on Phase Information
title_short The Ultrasonic Directional Tidal Breathing Pattern Sensor: Equitable Design Realization Based on Phase Information
title_sort ultrasonic directional tidal breathing pattern sensor: equitable design realization based on phase information
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579868/
https://www.ncbi.nlm.nih.gov/pubmed/28800103
http://dx.doi.org/10.3390/s17081853
work_keys_str_mv AT sinharayarijit theultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT rakshitraj theultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT khasnobishanwesha theultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT chakravartytapas theultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT ghoshdeb theultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT palarpan theultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT sinharayarijit ultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT rakshitraj ultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT khasnobishanwesha ultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT chakravartytapas ultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT ghoshdeb ultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation
AT palarpan ultrasonicdirectionaltidalbreathingpatternsensorequitabledesignrealizationbasedonphaseinformation