Cargando…

The development and validation of an easy to use automatic QT-interval algorithm

BACKGROUND: To evaluate QT-interval dynamics in patients and in drug safety analysis, beat-to-beat QT-interval measurements are increasingly used. However, interobserver differences, aberrant T-wave morphologies and changes in heart axis might hamper accurate QT-interval measurements. OBJECTIVE: To...

Descripción completa

Detalles Bibliográficos
Autores principales: Hermans, Ben J. M., Vink, Arja S., Bennis, Frank C., Filippini, Luc H., Meijborg, Veronique M. F., Wilde, Arthur A. M., Pison, Laurent, Postema, Pieter G., Delhaas, Tammo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581168/
https://www.ncbi.nlm.nih.gov/pubmed/28863167
http://dx.doi.org/10.1371/journal.pone.0184352
_version_ 1783261014518661120
author Hermans, Ben J. M.
Vink, Arja S.
Bennis, Frank C.
Filippini, Luc H.
Meijborg, Veronique M. F.
Wilde, Arthur A. M.
Pison, Laurent
Postema, Pieter G.
Delhaas, Tammo
author_facet Hermans, Ben J. M.
Vink, Arja S.
Bennis, Frank C.
Filippini, Luc H.
Meijborg, Veronique M. F.
Wilde, Arthur A. M.
Pison, Laurent
Postema, Pieter G.
Delhaas, Tammo
author_sort Hermans, Ben J. M.
collection PubMed
description BACKGROUND: To evaluate QT-interval dynamics in patients and in drug safety analysis, beat-to-beat QT-interval measurements are increasingly used. However, interobserver differences, aberrant T-wave morphologies and changes in heart axis might hamper accurate QT-interval measurements. OBJECTIVE: To develop and validate a QT-interval algorithm robust to heart axis orientation and T-wave morphology that can be applied on a beat-to-beat basis. METHODS: Additionally to standard ECG leads, the root mean square (ECG(RMS)), standard deviation and vectorcardiogram were used. QRS-onset was defined from the ECG(RMS). T-wave end was defined per individual lead and scalar ECG using an automated tangent method. A median of all T-wave ends was used as the general T-wave end per beat. Supine-standing tests of 73 patients with Long-QT syndrome (LQTS) and 54 controls were used because they have wide ranges of RR and QT-intervals as well as changes in T-wave morphology and heart axis orientation. For each subject, automatically estimated QT-intervals in three random complexes chosen from the low, middle and high RR range, were compared with manually measured QT-intervals by three observers. RESULTS: After visual inspection of the randomly selected complexes, 21 complexes were excluded because of evident noise, too flat T-waves or premature ventricular beats. Bland-Altman analyses of automatically and manually determined QT-intervals showed a bias of <4ms and limits of agreement of ±25ms. Intra-class coefficient indicated excellent agreement (>0.9) between the algorithm and all observers individually as well as between the algorithm and the mean QT-interval of the observers. CONCLUSION: Our automated algorithm provides reliable beat-to-beat QT-interval assessment, robust to heart axis and T-wave morphology.
format Online
Article
Text
id pubmed-5581168
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-55811682017-09-15 The development and validation of an easy to use automatic QT-interval algorithm Hermans, Ben J. M. Vink, Arja S. Bennis, Frank C. Filippini, Luc H. Meijborg, Veronique M. F. Wilde, Arthur A. M. Pison, Laurent Postema, Pieter G. Delhaas, Tammo PLoS One Research Article BACKGROUND: To evaluate QT-interval dynamics in patients and in drug safety analysis, beat-to-beat QT-interval measurements are increasingly used. However, interobserver differences, aberrant T-wave morphologies and changes in heart axis might hamper accurate QT-interval measurements. OBJECTIVE: To develop and validate a QT-interval algorithm robust to heart axis orientation and T-wave morphology that can be applied on a beat-to-beat basis. METHODS: Additionally to standard ECG leads, the root mean square (ECG(RMS)), standard deviation and vectorcardiogram were used. QRS-onset was defined from the ECG(RMS). T-wave end was defined per individual lead and scalar ECG using an automated tangent method. A median of all T-wave ends was used as the general T-wave end per beat. Supine-standing tests of 73 patients with Long-QT syndrome (LQTS) and 54 controls were used because they have wide ranges of RR and QT-intervals as well as changes in T-wave morphology and heart axis orientation. For each subject, automatically estimated QT-intervals in three random complexes chosen from the low, middle and high RR range, were compared with manually measured QT-intervals by three observers. RESULTS: After visual inspection of the randomly selected complexes, 21 complexes were excluded because of evident noise, too flat T-waves or premature ventricular beats. Bland-Altman analyses of automatically and manually determined QT-intervals showed a bias of <4ms and limits of agreement of ±25ms. Intra-class coefficient indicated excellent agreement (>0.9) between the algorithm and all observers individually as well as between the algorithm and the mean QT-interval of the observers. CONCLUSION: Our automated algorithm provides reliable beat-to-beat QT-interval assessment, robust to heart axis and T-wave morphology. Public Library of Science 2017-09-01 /pmc/articles/PMC5581168/ /pubmed/28863167 http://dx.doi.org/10.1371/journal.pone.0184352 Text en © 2017 Hermans et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Hermans, Ben J. M.
Vink, Arja S.
Bennis, Frank C.
Filippini, Luc H.
Meijborg, Veronique M. F.
Wilde, Arthur A. M.
Pison, Laurent
Postema, Pieter G.
Delhaas, Tammo
The development and validation of an easy to use automatic QT-interval algorithm
title The development and validation of an easy to use automatic QT-interval algorithm
title_full The development and validation of an easy to use automatic QT-interval algorithm
title_fullStr The development and validation of an easy to use automatic QT-interval algorithm
title_full_unstemmed The development and validation of an easy to use automatic QT-interval algorithm
title_short The development and validation of an easy to use automatic QT-interval algorithm
title_sort development and validation of an easy to use automatic qt-interval algorithm
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581168/
https://www.ncbi.nlm.nih.gov/pubmed/28863167
http://dx.doi.org/10.1371/journal.pone.0184352
work_keys_str_mv AT hermansbenjm thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT vinkarjas thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT bennisfrankc thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT filippiniluch thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT meijborgveroniquemf thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT wildearthuram thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT pisonlaurent thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT postemapieterg thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT delhaastammo thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT hermansbenjm developmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT vinkarjas developmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT bennisfrankc developmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT filippiniluch developmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT meijborgveroniquemf developmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT wildearthuram developmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT pisonlaurent developmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT postemapieterg developmentandvalidationofaneasytouseautomaticqtintervalalgorithm
AT delhaastammo developmentandvalidationofaneasytouseautomaticqtintervalalgorithm