Cargando…
The development and validation of an easy to use automatic QT-interval algorithm
BACKGROUND: To evaluate QT-interval dynamics in patients and in drug safety analysis, beat-to-beat QT-interval measurements are increasingly used. However, interobserver differences, aberrant T-wave morphologies and changes in heart axis might hamper accurate QT-interval measurements. OBJECTIVE: To...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581168/ https://www.ncbi.nlm.nih.gov/pubmed/28863167 http://dx.doi.org/10.1371/journal.pone.0184352 |
_version_ | 1783261014518661120 |
---|---|
author | Hermans, Ben J. M. Vink, Arja S. Bennis, Frank C. Filippini, Luc H. Meijborg, Veronique M. F. Wilde, Arthur A. M. Pison, Laurent Postema, Pieter G. Delhaas, Tammo |
author_facet | Hermans, Ben J. M. Vink, Arja S. Bennis, Frank C. Filippini, Luc H. Meijborg, Veronique M. F. Wilde, Arthur A. M. Pison, Laurent Postema, Pieter G. Delhaas, Tammo |
author_sort | Hermans, Ben J. M. |
collection | PubMed |
description | BACKGROUND: To evaluate QT-interval dynamics in patients and in drug safety analysis, beat-to-beat QT-interval measurements are increasingly used. However, interobserver differences, aberrant T-wave morphologies and changes in heart axis might hamper accurate QT-interval measurements. OBJECTIVE: To develop and validate a QT-interval algorithm robust to heart axis orientation and T-wave morphology that can be applied on a beat-to-beat basis. METHODS: Additionally to standard ECG leads, the root mean square (ECG(RMS)), standard deviation and vectorcardiogram were used. QRS-onset was defined from the ECG(RMS). T-wave end was defined per individual lead and scalar ECG using an automated tangent method. A median of all T-wave ends was used as the general T-wave end per beat. Supine-standing tests of 73 patients with Long-QT syndrome (LQTS) and 54 controls were used because they have wide ranges of RR and QT-intervals as well as changes in T-wave morphology and heart axis orientation. For each subject, automatically estimated QT-intervals in three random complexes chosen from the low, middle and high RR range, were compared with manually measured QT-intervals by three observers. RESULTS: After visual inspection of the randomly selected complexes, 21 complexes were excluded because of evident noise, too flat T-waves or premature ventricular beats. Bland-Altman analyses of automatically and manually determined QT-intervals showed a bias of <4ms and limits of agreement of ±25ms. Intra-class coefficient indicated excellent agreement (>0.9) between the algorithm and all observers individually as well as between the algorithm and the mean QT-interval of the observers. CONCLUSION: Our automated algorithm provides reliable beat-to-beat QT-interval assessment, robust to heart axis and T-wave morphology. |
format | Online Article Text |
id | pubmed-5581168 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-55811682017-09-15 The development and validation of an easy to use automatic QT-interval algorithm Hermans, Ben J. M. Vink, Arja S. Bennis, Frank C. Filippini, Luc H. Meijborg, Veronique M. F. Wilde, Arthur A. M. Pison, Laurent Postema, Pieter G. Delhaas, Tammo PLoS One Research Article BACKGROUND: To evaluate QT-interval dynamics in patients and in drug safety analysis, beat-to-beat QT-interval measurements are increasingly used. However, interobserver differences, aberrant T-wave morphologies and changes in heart axis might hamper accurate QT-interval measurements. OBJECTIVE: To develop and validate a QT-interval algorithm robust to heart axis orientation and T-wave morphology that can be applied on a beat-to-beat basis. METHODS: Additionally to standard ECG leads, the root mean square (ECG(RMS)), standard deviation and vectorcardiogram were used. QRS-onset was defined from the ECG(RMS). T-wave end was defined per individual lead and scalar ECG using an automated tangent method. A median of all T-wave ends was used as the general T-wave end per beat. Supine-standing tests of 73 patients with Long-QT syndrome (LQTS) and 54 controls were used because they have wide ranges of RR and QT-intervals as well as changes in T-wave morphology and heart axis orientation. For each subject, automatically estimated QT-intervals in three random complexes chosen from the low, middle and high RR range, were compared with manually measured QT-intervals by three observers. RESULTS: After visual inspection of the randomly selected complexes, 21 complexes were excluded because of evident noise, too flat T-waves or premature ventricular beats. Bland-Altman analyses of automatically and manually determined QT-intervals showed a bias of <4ms and limits of agreement of ±25ms. Intra-class coefficient indicated excellent agreement (>0.9) between the algorithm and all observers individually as well as between the algorithm and the mean QT-interval of the observers. CONCLUSION: Our automated algorithm provides reliable beat-to-beat QT-interval assessment, robust to heart axis and T-wave morphology. Public Library of Science 2017-09-01 /pmc/articles/PMC5581168/ /pubmed/28863167 http://dx.doi.org/10.1371/journal.pone.0184352 Text en © 2017 Hermans et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Hermans, Ben J. M. Vink, Arja S. Bennis, Frank C. Filippini, Luc H. Meijborg, Veronique M. F. Wilde, Arthur A. M. Pison, Laurent Postema, Pieter G. Delhaas, Tammo The development and validation of an easy to use automatic QT-interval algorithm |
title | The development and validation of an easy to use automatic QT-interval algorithm |
title_full | The development and validation of an easy to use automatic QT-interval algorithm |
title_fullStr | The development and validation of an easy to use automatic QT-interval algorithm |
title_full_unstemmed | The development and validation of an easy to use automatic QT-interval algorithm |
title_short | The development and validation of an easy to use automatic QT-interval algorithm |
title_sort | development and validation of an easy to use automatic qt-interval algorithm |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581168/ https://www.ncbi.nlm.nih.gov/pubmed/28863167 http://dx.doi.org/10.1371/journal.pone.0184352 |
work_keys_str_mv | AT hermansbenjm thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT vinkarjas thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT bennisfrankc thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT filippiniluch thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT meijborgveroniquemf thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT wildearthuram thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT pisonlaurent thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT postemapieterg thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT delhaastammo thedevelopmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT hermansbenjm developmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT vinkarjas developmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT bennisfrankc developmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT filippiniluch developmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT meijborgveroniquemf developmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT wildearthuram developmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT pisonlaurent developmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT postemapieterg developmentandvalidationofaneasytouseautomaticqtintervalalgorithm AT delhaastammo developmentandvalidationofaneasytouseautomaticqtintervalalgorithm |