Cargando…
Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring
A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narr...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581315/ https://www.ncbi.nlm.nih.gov/pubmed/28894734 http://dx.doi.org/10.3389/fchem.2017.00062 |
_version_ | 1783261021524197376 |
---|---|
author | Roberg-Larsen, Hanne Abele, Silvija Demir, Deniz Dzabijeva, Diana Amundsen, Sunniva F. Wilson, Steven R. Bartkevics, Vadims Lundanes, Elsa |
author_facet | Roberg-Larsen, Hanne Abele, Silvija Demir, Deniz Dzabijeva, Diana Amundsen, Sunniva F. Wilson, Steven R. Bartkevics, Vadims Lundanes, Elsa |
author_sort | Roberg-Larsen, Hanne |
collection | PubMed |
description | A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g., injection of 100 non-filtrated water samples did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 μm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for environmental water samples was demonstrated with various pharmaceutical products, which had detection limits (LOD) in the 0.05–12.5 ng/L range. Between-day and within-day repeatability of selected analytes were <20% RSD. |
format | Online Article Text |
id | pubmed-5581315 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-55813152017-09-11 Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring Roberg-Larsen, Hanne Abele, Silvija Demir, Deniz Dzabijeva, Diana Amundsen, Sunniva F. Wilson, Steven R. Bartkevics, Vadims Lundanes, Elsa Front Chem Chemistry A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g., injection of 100 non-filtrated water samples did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 μm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for environmental water samples was demonstrated with various pharmaceutical products, which had detection limits (LOD) in the 0.05–12.5 ng/L range. Between-day and within-day repeatability of selected analytes were <20% RSD. Frontiers Media S.A. 2017-08-28 /pmc/articles/PMC5581315/ /pubmed/28894734 http://dx.doi.org/10.3389/fchem.2017.00062 Text en Copyright © 2017 Roberg-Larsen, Abele, Demir, Dzabijeva, Amundsen, Wilson, Bartkevics and Lundanes. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Chemistry Roberg-Larsen, Hanne Abele, Silvija Demir, Deniz Dzabijeva, Diana Amundsen, Sunniva F. Wilson, Steven R. Bartkevics, Vadims Lundanes, Elsa Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring |
title | Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring |
title_full | Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring |
title_fullStr | Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring |
title_full_unstemmed | Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring |
title_short | Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring |
title_sort | rugged large volume injection for sensitive capillary lc-ms environmental monitoring |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581315/ https://www.ncbi.nlm.nih.gov/pubmed/28894734 http://dx.doi.org/10.3389/fchem.2017.00062 |
work_keys_str_mv | AT roberglarsenhanne ruggedlargevolumeinjectionforsensitivecapillarylcmsenvironmentalmonitoring AT abelesilvija ruggedlargevolumeinjectionforsensitivecapillarylcmsenvironmentalmonitoring AT demirdeniz ruggedlargevolumeinjectionforsensitivecapillarylcmsenvironmentalmonitoring AT dzabijevadiana ruggedlargevolumeinjectionforsensitivecapillarylcmsenvironmentalmonitoring AT amundsensunnivaf ruggedlargevolumeinjectionforsensitivecapillarylcmsenvironmentalmonitoring AT wilsonstevenr ruggedlargevolumeinjectionforsensitivecapillarylcmsenvironmentalmonitoring AT bartkevicsvadims ruggedlargevolumeinjectionforsensitivecapillarylcmsenvironmentalmonitoring AT lundaneselsa ruggedlargevolumeinjectionforsensitivecapillarylcmsenvironmentalmonitoring |