Cargando…

Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44–48 mm), a single Chinese cardiac center experience

BACKGROUND: The purpose of this study was to outline the midterm follow-up results and complications in patients who underwent transthoracic device closure of an atrial septal defect (ASD) with the very large domestic occluder (44–48 mm). METHODS: The data of 35 patients who underwent transthoracic...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Qiang, Cao, Hua, Zhang, Gui-Can, Chen, Liang-wan, Xu, Fan, Zhang, Jia-xin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581445/
https://www.ncbi.nlm.nih.gov/pubmed/28865489
http://dx.doi.org/10.1186/s13019-017-0639-8
_version_ 1783261049993035776
author Chen, Qiang
Cao, Hua
Zhang, Gui-Can
Chen, Liang-wan
Xu, Fan
Zhang, Jia-xin
author_facet Chen, Qiang
Cao, Hua
Zhang, Gui-Can
Chen, Liang-wan
Xu, Fan
Zhang, Jia-xin
author_sort Chen, Qiang
collection PubMed
description BACKGROUND: The purpose of this study was to outline the midterm follow-up results and complications in patients who underwent transthoracic device closure of an atrial septal defect (ASD) with the very large domestic occluder (44–48 mm). METHODS: The data of 35 patients who underwent transthoracic device closure of an ASD with the very large domestic occluder (44–48 mm) at our institution were collected prospectively between January 2010 and January 2015. All patients were invited for an outpatient visit and contrast TTE for 12–70 months after ASD closure. RESULTS: Thirty-four patients were occluded successfully under this approach and 1 patient was transferred for surgical repair for dislodgement of the occluder. The most frequent complication was transient cardiac arrhythmia. A new third degree atrioventricular block occurred in 1 patient who recovered 1 week later. During the follow-up period, we found no recurrence, no thrombosis, no device embolization, no device failure, and no cases of death. The total occlusion rate was 94.1% in the 12 months of follow-up, and the intracardiac structure and cardiac function were significant improved contemporaneously. CONCLUSION: Transthoracic device closure of an atrial septal defect with the very large domestic occluder (44–48 mm) is a safe and feasible technique. However, long-term follow-up is required to better assess the safety and feasibility of this method for the closure of very large ASDs in patients.
format Online
Article
Text
id pubmed-5581445
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-55814452017-09-06 Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44–48 mm), a single Chinese cardiac center experience Chen, Qiang Cao, Hua Zhang, Gui-Can Chen, Liang-wan Xu, Fan Zhang, Jia-xin J Cardiothorac Surg Research Article BACKGROUND: The purpose of this study was to outline the midterm follow-up results and complications in patients who underwent transthoracic device closure of an atrial septal defect (ASD) with the very large domestic occluder (44–48 mm). METHODS: The data of 35 patients who underwent transthoracic device closure of an ASD with the very large domestic occluder (44–48 mm) at our institution were collected prospectively between January 2010 and January 2015. All patients were invited for an outpatient visit and contrast TTE for 12–70 months after ASD closure. RESULTS: Thirty-four patients were occluded successfully under this approach and 1 patient was transferred for surgical repair for dislodgement of the occluder. The most frequent complication was transient cardiac arrhythmia. A new third degree atrioventricular block occurred in 1 patient who recovered 1 week later. During the follow-up period, we found no recurrence, no thrombosis, no device embolization, no device failure, and no cases of death. The total occlusion rate was 94.1% in the 12 months of follow-up, and the intracardiac structure and cardiac function were significant improved contemporaneously. CONCLUSION: Transthoracic device closure of an atrial septal defect with the very large domestic occluder (44–48 mm) is a safe and feasible technique. However, long-term follow-up is required to better assess the safety and feasibility of this method for the closure of very large ASDs in patients. BioMed Central 2017-09-02 /pmc/articles/PMC5581445/ /pubmed/28865489 http://dx.doi.org/10.1186/s13019-017-0639-8 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Chen, Qiang
Cao, Hua
Zhang, Gui-Can
Chen, Liang-wan
Xu, Fan
Zhang, Jia-xin
Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44–48 mm), a single Chinese cardiac center experience
title Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44–48 mm), a single Chinese cardiac center experience
title_full Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44–48 mm), a single Chinese cardiac center experience
title_fullStr Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44–48 mm), a single Chinese cardiac center experience
title_full_unstemmed Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44–48 mm), a single Chinese cardiac center experience
title_short Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44–48 mm), a single Chinese cardiac center experience
title_sort midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44–48 mm), a single chinese cardiac center experience
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581445/
https://www.ncbi.nlm.nih.gov/pubmed/28865489
http://dx.doi.org/10.1186/s13019-017-0639-8
work_keys_str_mv AT chenqiang midtermfollowupoftransthoracicdeviceclosureofanatrialseptaldefectusingtheverylargedomesticoccluder4448mmasinglechinesecardiaccenterexperience
AT caohua midtermfollowupoftransthoracicdeviceclosureofanatrialseptaldefectusingtheverylargedomesticoccluder4448mmasinglechinesecardiaccenterexperience
AT zhangguican midtermfollowupoftransthoracicdeviceclosureofanatrialseptaldefectusingtheverylargedomesticoccluder4448mmasinglechinesecardiaccenterexperience
AT chenliangwan midtermfollowupoftransthoracicdeviceclosureofanatrialseptaldefectusingtheverylargedomesticoccluder4448mmasinglechinesecardiaccenterexperience
AT xufan midtermfollowupoftransthoracicdeviceclosureofanatrialseptaldefectusingtheverylargedomesticoccluder4448mmasinglechinesecardiaccenterexperience
AT zhangjiaxin midtermfollowupoftransthoracicdeviceclosureofanatrialseptaldefectusingtheverylargedomesticoccluder4448mmasinglechinesecardiaccenterexperience