Cargando…

S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative

INTRODUCTION: The objective of this study is to test the null hypothesis that an S-shaped surgical incision versus conventional (straight) skin incision in the creation of autogenous radiocephalic arteriovenous fistulas (RCAVFs) have no impact on the primary end-point of primary functional maturatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Kordzadeh, Ali, Panayiotopolous, Yiannis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581847/
https://www.ncbi.nlm.nih.gov/pubmed/28878893
http://dx.doi.org/10.1016/j.amsu.2017.08.018
_version_ 1783261105818173440
author Kordzadeh, Ali
Panayiotopolous, Yiannis
author_facet Kordzadeh, Ali
Panayiotopolous, Yiannis
author_sort Kordzadeh, Ali
collection PubMed
description INTRODUCTION: The objective of this study is to test the null hypothesis that an S-shaped surgical incision versus conventional (straight) skin incision in the creation of autogenous radiocephalic arteriovenous fistulas (RCAVFs) have no impact on the primary end-point of primary functional maturation and secondary end points of stenosis and thrombosis. METHODS: A prospective observational comparative consecutive study with intention-to-treat on individuals undergoing only radiocephalic arteriovenous fistula (RCAVFs) over a period of 12 months was conducted. Variables on patient's demographics, comorbidities, anesthesia type, mean arterial blood pressure, thrill, laterality, cephalic vein and radial artery diameter were collated. The test of probability was assessed through Chi-Square, Kaplan-Meier survival estimator and Log-Rank analysis. RESULTS: Total of n = 83 individuals with median age of 67 years (IQR, 20–89) and male predominance 83% during this period were subjected to RCAVF formation. Total of n = 45 patients in straight skin incision were compared to n = 38 individuals in S-shaped group. Despite equal prevalence of demographics, comorbidities, anesthesia type, mean arterial blood pressure (MAP), thrill, laterality, cephalic vein and radial artery diameter (p > 0.05) higher incidence of juxta-anastomotic stenosis was noted in the straight skin incision group (p = 0.029) in comparative and survival analysis (Log-Rank, p = 0.036). The maturation of the entire cohort was 69% (S-shaped 76% vs. straight group 62%) (p > 0.05). CONCLUSION: The outcome of this study demonstrates that S-shaped surgical skin incision is associated with a lower incidence of stenosis in comparison to straight incision type in RCAVF formation.
format Online
Article
Text
id pubmed-5581847
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-55818472017-09-06 S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative Kordzadeh, Ali Panayiotopolous, Yiannis Ann Med Surg (Lond) Original Research INTRODUCTION: The objective of this study is to test the null hypothesis that an S-shaped surgical incision versus conventional (straight) skin incision in the creation of autogenous radiocephalic arteriovenous fistulas (RCAVFs) have no impact on the primary end-point of primary functional maturation and secondary end points of stenosis and thrombosis. METHODS: A prospective observational comparative consecutive study with intention-to-treat on individuals undergoing only radiocephalic arteriovenous fistula (RCAVFs) over a period of 12 months was conducted. Variables on patient's demographics, comorbidities, anesthesia type, mean arterial blood pressure, thrill, laterality, cephalic vein and radial artery diameter were collated. The test of probability was assessed through Chi-Square, Kaplan-Meier survival estimator and Log-Rank analysis. RESULTS: Total of n = 83 individuals with median age of 67 years (IQR, 20–89) and male predominance 83% during this period were subjected to RCAVF formation. Total of n = 45 patients in straight skin incision were compared to n = 38 individuals in S-shaped group. Despite equal prevalence of demographics, comorbidities, anesthesia type, mean arterial blood pressure (MAP), thrill, laterality, cephalic vein and radial artery diameter (p > 0.05) higher incidence of juxta-anastomotic stenosis was noted in the straight skin incision group (p = 0.029) in comparative and survival analysis (Log-Rank, p = 0.036). The maturation of the entire cohort was 69% (S-shaped 76% vs. straight group 62%) (p > 0.05). CONCLUSION: The outcome of this study demonstrates that S-shaped surgical skin incision is associated with a lower incidence of stenosis in comparison to straight incision type in RCAVF formation. Elsevier 2017-08-30 /pmc/articles/PMC5581847/ /pubmed/28878893 http://dx.doi.org/10.1016/j.amsu.2017.08.018 Text en © 2017 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Kordzadeh, Ali
Panayiotopolous, Yiannis
S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative
title S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative
title_full S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative
title_fullStr S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative
title_full_unstemmed S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative
title_short S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative
title_sort s-shaped versus conventional straight skin incision: impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: impact of incision on maturation, stenosis & failure of rcavf. study design: prospective observational comparative
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5581847/
https://www.ncbi.nlm.nih.gov/pubmed/28878893
http://dx.doi.org/10.1016/j.amsu.2017.08.018
work_keys_str_mv AT kordzadehali sshapedversusconventionalstraightskinincisionimpactonprimaryfunctionalmaturationstenosisandthrombosisofautogenousradiocephalicarteriovenousfistulaimpactofincisiononmaturationstenosisfailureofrcavfstudydesignprospectiveobservationalcomparative
AT panayiotopolousyiannis sshapedversusconventionalstraightskinincisionimpactonprimaryfunctionalmaturationstenosisandthrombosisofautogenousradiocephalicarteriovenousfistulaimpactofincisiononmaturationstenosisfailureofrcavfstudydesignprospectiveobservationalcomparative