Cargando…

In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses

PURPOSE: The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS: Co-Cr alloy three-unit...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Jae-Won, Kim, So-Yeun, Bae, Ji-Hyeon, Bae, Eun-Bin, Huh, Jung-Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5582089/
https://www.ncbi.nlm.nih.gov/pubmed/28874990
http://dx.doi.org/10.4047/jap.2017.9.4.244
_version_ 1783261126571589632
author Choi, Jae-Won
Kim, So-Yeun
Bae, Ji-Hyeon
Bae, Eun-Bin
Huh, Jung-Bo
author_facet Choi, Jae-Won
Kim, So-Yeun
Bae, Ji-Hyeon
Bae, Eun-Bin
Huh, Jung-Bo
author_sort Choi, Jae-Won
collection PubMed
description PURPOSE: The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS: Co-Cr alloy three-unit metal FDPs model with maxillary first premolar and first molar abutments was fabricated. Three different FDPs groups, LZ, ML, and MZ, were prepared (n = 5 per group). The three-unit FDPs designs were identical for all specimens and cemented with resin cement on the prepared metal model. The region of pontic in FDPs was given 50,000 times of cyclic preloading at 2 Hz via dental chewing simulator and received a static load until fracture with universal testing machine fixed at 10°. The fracture resistance and mode of failure were recorded. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni's correction (α=0.05/3=0.017). RESULTS: A significant difference in fracture resistance was found between LZ (4943.87 ± 1243.70 N) and ML (2872.61 ± 658.78 N) groups, as well as between ML and MZ (4948.02 ± 974.51 N) groups (P<.05), but no significant difference was found between LZ and MZ groups (P>.05). With regard to fracture pattern, there were three cases of veneer chipping and two interfacial fractures in LZ group, and complete fracture was observed in all the specimens of ML and MZ groups. CONCLUSION: Compared to monolithic lithium disilicate FDPs, monolithic zirconia FDPs and lithium disilicate glass ceramics pressed on zirconia-based FDPs showed superior fracture resistance while they manifested comparable fracture resistances.
format Online
Article
Text
id pubmed-5582089
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-55820892017-09-05 In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses Choi, Jae-Won Kim, So-Yeun Bae, Ji-Hyeon Bae, Eun-Bin Huh, Jung-Bo J Adv Prosthodont Original Article PURPOSE: The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS: Co-Cr alloy three-unit metal FDPs model with maxillary first premolar and first molar abutments was fabricated. Three different FDPs groups, LZ, ML, and MZ, were prepared (n = 5 per group). The three-unit FDPs designs were identical for all specimens and cemented with resin cement on the prepared metal model. The region of pontic in FDPs was given 50,000 times of cyclic preloading at 2 Hz via dental chewing simulator and received a static load until fracture with universal testing machine fixed at 10°. The fracture resistance and mode of failure were recorded. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni's correction (α=0.05/3=0.017). RESULTS: A significant difference in fracture resistance was found between LZ (4943.87 ± 1243.70 N) and ML (2872.61 ± 658.78 N) groups, as well as between ML and MZ (4948.02 ± 974.51 N) groups (P<.05), but no significant difference was found between LZ and MZ groups (P>.05). With regard to fracture pattern, there were three cases of veneer chipping and two interfacial fractures in LZ group, and complete fracture was observed in all the specimens of ML and MZ groups. CONCLUSION: Compared to monolithic lithium disilicate FDPs, monolithic zirconia FDPs and lithium disilicate glass ceramics pressed on zirconia-based FDPs showed superior fracture resistance while they manifested comparable fracture resistances. The Korean Academy of Prosthodontics 2017-08 2017-08-16 /pmc/articles/PMC5582089/ /pubmed/28874990 http://dx.doi.org/10.4047/jap.2017.9.4.244 Text en © 2017 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Choi, Jae-Won
Kim, So-Yeun
Bae, Ji-Hyeon
Bae, Eun-Bin
Huh, Jung-Bo
In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
title In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
title_full In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
title_fullStr In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
title_full_unstemmed In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
title_short In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
title_sort in vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5582089/
https://www.ncbi.nlm.nih.gov/pubmed/28874990
http://dx.doi.org/10.4047/jap.2017.9.4.244
work_keys_str_mv AT choijaewon invitrostudyofthefractureresistanceofmonolithiclithiumdisilicatemonolithiczirconiaandlithiumdisilicatepressedonzirconiaforthreeunitfixeddentalprostheses
AT kimsoyeun invitrostudyofthefractureresistanceofmonolithiclithiumdisilicatemonolithiczirconiaandlithiumdisilicatepressedonzirconiaforthreeunitfixeddentalprostheses
AT baejihyeon invitrostudyofthefractureresistanceofmonolithiclithiumdisilicatemonolithiczirconiaandlithiumdisilicatepressedonzirconiaforthreeunitfixeddentalprostheses
AT baeeunbin invitrostudyofthefractureresistanceofmonolithiclithiumdisilicatemonolithiczirconiaandlithiumdisilicatepressedonzirconiaforthreeunitfixeddentalprostheses
AT huhjungbo invitrostudyofthefractureresistanceofmonolithiclithiumdisilicatemonolithiczirconiaandlithiumdisilicatepressedonzirconiaforthreeunitfixeddentalprostheses