Cargando…
Intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner‐air density of tumors
BACKGROUND: This study was conducted to assess intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion (DCTP) in patients with lung cancer. METHODS: A total of 88 patients who had undergone DCTP, which had proved a diagnosis of primary...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons Australia, Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5582470/ https://www.ncbi.nlm.nih.gov/pubmed/28585375 http://dx.doi.org/10.1111/1759-7714.12458 |
_version_ | 1783261195328815104 |
---|---|
author | Wang, Qingle Zhang, Zhiyong Shan, Fei Shi, Yuxin Xing, Wei Shi, Liangrong Zhang, Xingwei |
author_facet | Wang, Qingle Zhang, Zhiyong Shan, Fei Shi, Yuxin Xing, Wei Shi, Liangrong Zhang, Xingwei |
author_sort | Wang, Qingle |
collection | PubMed |
description | BACKGROUND: This study was conducted to assess intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion (DCTP) in patients with lung cancer. METHODS: A total of 88 patients who had undergone DCTP, which had proved a diagnosis of primary lung cancer, were divided into two groups: (i) nodules (diameter ≤3 cm) and masses (diameter >3 cm) by size, and (ii) tumors with and without air density. Pulmonary flow, bronchial flow, and pulmonary index were measured in each group. Intra‐observer and inter‐observer agreements for measurement were assessed using intraclass correlation coefficient, within‐subject coefficient of variation, and Bland–Altman analysis. RESULTS: In all lung cancers, the reproducibility coefficient for intra‐observer agreement (range 26.1–38.3%) was superior to inter‐observer agreement (range 38.1–81.2%). Further analysis revealed lower agreements for nodules compared to masses. Additionally, inner‐air density reduced both agreements for lung cancer. CONCLUSION: The intra‐observer agreement for measuring lung cancer DCTP was satisfied, while the inter‐observer agreement was limited. The effects of tumoral size and inner‐air density to agreements, especially between two observers, should be emphasized. In future, an automatic computer‐aided segment of perfusion value of the tumor should be developed. |
format | Online Article Text |
id | pubmed-5582470 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | John Wiley & Sons Australia, Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-55824702017-09-06 Intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner‐air density of tumors Wang, Qingle Zhang, Zhiyong Shan, Fei Shi, Yuxin Xing, Wei Shi, Liangrong Zhang, Xingwei Thorac Cancer Original Articles BACKGROUND: This study was conducted to assess intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion (DCTP) in patients with lung cancer. METHODS: A total of 88 patients who had undergone DCTP, which had proved a diagnosis of primary lung cancer, were divided into two groups: (i) nodules (diameter ≤3 cm) and masses (diameter >3 cm) by size, and (ii) tumors with and without air density. Pulmonary flow, bronchial flow, and pulmonary index were measured in each group. Intra‐observer and inter‐observer agreements for measurement were assessed using intraclass correlation coefficient, within‐subject coefficient of variation, and Bland–Altman analysis. RESULTS: In all lung cancers, the reproducibility coefficient for intra‐observer agreement (range 26.1–38.3%) was superior to inter‐observer agreement (range 38.1–81.2%). Further analysis revealed lower agreements for nodules compared to masses. Additionally, inner‐air density reduced both agreements for lung cancer. CONCLUSION: The intra‐observer agreement for measuring lung cancer DCTP was satisfied, while the inter‐observer agreement was limited. The effects of tumoral size and inner‐air density to agreements, especially between two observers, should be emphasized. In future, an automatic computer‐aided segment of perfusion value of the tumor should be developed. John Wiley & Sons Australia, Ltd 2017-06-06 2017-09 /pmc/articles/PMC5582470/ /pubmed/28585375 http://dx.doi.org/10.1111/1759-7714.12458 Text en © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Articles Wang, Qingle Zhang, Zhiyong Shan, Fei Shi, Yuxin Xing, Wei Shi, Liangrong Zhang, Xingwei Intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner‐air density of tumors |
title | Intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner‐air density of tumors |
title_full | Intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner‐air density of tumors |
title_fullStr | Intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner‐air density of tumors |
title_full_unstemmed | Intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner‐air density of tumors |
title_short | Intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner‐air density of tumors |
title_sort | intra‐observer and inter‐observer agreements for the measurement of dual‐input whole tumor computed tomography perfusion in patients with lung cancer: influences of the size and inner‐air density of tumors |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5582470/ https://www.ncbi.nlm.nih.gov/pubmed/28585375 http://dx.doi.org/10.1111/1759-7714.12458 |
work_keys_str_mv | AT wangqingle intraobserverandinterobserveragreementsforthemeasurementofdualinputwholetumorcomputedtomographyperfusioninpatientswithlungcancerinfluencesofthesizeandinnerairdensityoftumors AT zhangzhiyong intraobserverandinterobserveragreementsforthemeasurementofdualinputwholetumorcomputedtomographyperfusioninpatientswithlungcancerinfluencesofthesizeandinnerairdensityoftumors AT shanfei intraobserverandinterobserveragreementsforthemeasurementofdualinputwholetumorcomputedtomographyperfusioninpatientswithlungcancerinfluencesofthesizeandinnerairdensityoftumors AT shiyuxin intraobserverandinterobserveragreementsforthemeasurementofdualinputwholetumorcomputedtomographyperfusioninpatientswithlungcancerinfluencesofthesizeandinnerairdensityoftumors AT xingwei intraobserverandinterobserveragreementsforthemeasurementofdualinputwholetumorcomputedtomographyperfusioninpatientswithlungcancerinfluencesofthesizeandinnerairdensityoftumors AT shiliangrong intraobserverandinterobserveragreementsforthemeasurementofdualinputwholetumorcomputedtomographyperfusioninpatientswithlungcancerinfluencesofthesizeandinnerairdensityoftumors AT zhangxingwei intraobserverandinterobserveragreementsforthemeasurementofdualinputwholetumorcomputedtomographyperfusioninpatientswithlungcancerinfluencesofthesizeandinnerairdensityoftumors |