Artificial urinary sphincter

Although currently still the gold standard treatment for post-prostatectomy urinary incontinence, the artificial urinary sphincter (AUS) (AMS800) is an invasive procedure with associated risks factors. In this paper, we aim to outline what the scientific literature and what we personally believe are...

Descripción completa

Detalles Bibliográficos
Autores principales: Brant, William O., Martins, Francisco E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5583059/
https://www.ncbi.nlm.nih.gov/pubmed/28904901
http://dx.doi.org/10.21037/tau.2017.07.31
Descripción
Sumario:Although currently still the gold standard treatment for post-prostatectomy urinary incontinence, the artificial urinary sphincter (AUS) (AMS800) is an invasive procedure with associated risks factors. In this paper, we aim to outline what the scientific literature and what we personally believe are the factors that are useful and/or necessary to mitigate these risks, including both patient factors and surgeon factors. We also review special populations, including transcorporal (TC) AUS approach, AUS with inflatable penile prosthesis, AUS after male urethral sling, AUS erosion management, and AUS after orthotopic urinary diversion.