Cargando…

Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision

Correlative light-electron microscopy (CLEM) combines the high spatial resolution of transmission electron microscopy (TEM) with the capability of fluorescence light microscopy (FLM) to locate rare or transient cellular events within a large field of view. CLEM is therefore a powerful technique to s...

Descripción completa

Detalles Bibliográficos
Autores principales: Tuijtel, Maarten W., Mulder, Aat A., Posthuma, Clara C., van der Hoeven, Barbara, Koster, Abraham J., Bárcena, Montserrat, Faas, Frank G. A., Sharp, Thomas H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5585351/
https://www.ncbi.nlm.nih.gov/pubmed/28874723
http://dx.doi.org/10.1038/s41598-017-10905-x
_version_ 1783261605698469888
author Tuijtel, Maarten W.
Mulder, Aat A.
Posthuma, Clara C.
van der Hoeven, Barbara
Koster, Abraham J.
Bárcena, Montserrat
Faas, Frank G. A.
Sharp, Thomas H.
author_facet Tuijtel, Maarten W.
Mulder, Aat A.
Posthuma, Clara C.
van der Hoeven, Barbara
Koster, Abraham J.
Bárcena, Montserrat
Faas, Frank G. A.
Sharp, Thomas H.
author_sort Tuijtel, Maarten W.
collection PubMed
description Correlative light-electron microscopy (CLEM) combines the high spatial resolution of transmission electron microscopy (TEM) with the capability of fluorescence light microscopy (FLM) to locate rare or transient cellular events within a large field of view. CLEM is therefore a powerful technique to study cellular processes. Aligning images derived from both imaging modalities is a prerequisite to correlate the two microscopy data sets, and poor alignment can limit interpretability of the data. Here, we describe how uranyl acetate, a commonly-used contrast agent for TEM, can be induced to fluoresce brightly at cryogenic temperatures (−195 °C) and imaged by cryoFLM using standard filter sets. This dual-purpose contrast agent can be used as a general tool for CLEM, whereby the equivalent staining allows direct correlation between fluorescence and TEM images. We demonstrate the potential of this approach by performing multi-colour CLEM of cells containing equine arteritis virus proteins tagged with either green- or red-fluorescent protein, and achieve high-precision localization of virus-induced intracellular membrane modifications. Using uranyl acetate as a dual-purpose contrast agent, we achieve an image alignment precision of ~30 nm, twice as accurate as when using fiducial beads, which will be essential for combining TEM with the evolving field of super-resolution light microscopy.
format Online
Article
Text
id pubmed-5585351
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-55853512017-09-06 Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision Tuijtel, Maarten W. Mulder, Aat A. Posthuma, Clara C. van der Hoeven, Barbara Koster, Abraham J. Bárcena, Montserrat Faas, Frank G. A. Sharp, Thomas H. Sci Rep Article Correlative light-electron microscopy (CLEM) combines the high spatial resolution of transmission electron microscopy (TEM) with the capability of fluorescence light microscopy (FLM) to locate rare or transient cellular events within a large field of view. CLEM is therefore a powerful technique to study cellular processes. Aligning images derived from both imaging modalities is a prerequisite to correlate the two microscopy data sets, and poor alignment can limit interpretability of the data. Here, we describe how uranyl acetate, a commonly-used contrast agent for TEM, can be induced to fluoresce brightly at cryogenic temperatures (−195 °C) and imaged by cryoFLM using standard filter sets. This dual-purpose contrast agent can be used as a general tool for CLEM, whereby the equivalent staining allows direct correlation between fluorescence and TEM images. We demonstrate the potential of this approach by performing multi-colour CLEM of cells containing equine arteritis virus proteins tagged with either green- or red-fluorescent protein, and achieve high-precision localization of virus-induced intracellular membrane modifications. Using uranyl acetate as a dual-purpose contrast agent, we achieve an image alignment precision of ~30 nm, twice as accurate as when using fiducial beads, which will be essential for combining TEM with the evolving field of super-resolution light microscopy. Nature Publishing Group UK 2017-09-05 /pmc/articles/PMC5585351/ /pubmed/28874723 http://dx.doi.org/10.1038/s41598-017-10905-x Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Tuijtel, Maarten W.
Mulder, Aat A.
Posthuma, Clara C.
van der Hoeven, Barbara
Koster, Abraham J.
Bárcena, Montserrat
Faas, Frank G. A.
Sharp, Thomas H.
Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision
title Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision
title_full Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision
title_fullStr Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision
title_full_unstemmed Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision
title_short Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision
title_sort inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5585351/
https://www.ncbi.nlm.nih.gov/pubmed/28874723
http://dx.doi.org/10.1038/s41598-017-10905-x
work_keys_str_mv AT tuijtelmaartenw inducingfluorescenceofuranylacetateasadualpurposecontrastagentforcorrelativelightelectronmicroscopywithnanometreprecision
AT mulderaata inducingfluorescenceofuranylacetateasadualpurposecontrastagentforcorrelativelightelectronmicroscopywithnanometreprecision
AT posthumaclarac inducingfluorescenceofuranylacetateasadualpurposecontrastagentforcorrelativelightelectronmicroscopywithnanometreprecision
AT vanderhoevenbarbara inducingfluorescenceofuranylacetateasadualpurposecontrastagentforcorrelativelightelectronmicroscopywithnanometreprecision
AT kosterabrahamj inducingfluorescenceofuranylacetateasadualpurposecontrastagentforcorrelativelightelectronmicroscopywithnanometreprecision
AT barcenamontserrat inducingfluorescenceofuranylacetateasadualpurposecontrastagentforcorrelativelightelectronmicroscopywithnanometreprecision
AT faasfrankga inducingfluorescenceofuranylacetateasadualpurposecontrastagentforcorrelativelightelectronmicroscopywithnanometreprecision
AT sharpthomash inducingfluorescenceofuranylacetateasadualpurposecontrastagentforcorrelativelightelectronmicroscopywithnanometreprecision