Cargando…

Prevention of Mandible Reconstruction Plate Exposure by Costal Cartilage Wrapping

After mandibulectomy in cancer surgery, reconstruction is often performed with a reconstruction plate covered with a soft-tissue free flap in patients in poor condition. However, the rate of complications for mandibular reconstruction is higher with a reconstruction plate than with vascularized bone...

Descripción completa

Detalles Bibliográficos
Autores principales: Iwasawa, Motonao, Mishima, Yoshito, Ohtsubo, Miho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5585432/
https://www.ncbi.nlm.nih.gov/pubmed/28894659
http://dx.doi.org/10.1097/GOX.0000000000001438
_version_ 1783261624672452608
author Iwasawa, Motonao
Mishima, Yoshito
Ohtsubo, Miho
author_facet Iwasawa, Motonao
Mishima, Yoshito
Ohtsubo, Miho
author_sort Iwasawa, Motonao
collection PubMed
description After mandibulectomy in cancer surgery, reconstruction is often performed with a reconstruction plate covered with a soft-tissue free flap in patients in poor condition. However, the rate of complications for mandibular reconstruction is higher with a reconstruction plate than with vascularized bone grafts. We have developed a costal cartilage wrapping method to prevent exposure of the mandible reconstruction plate. The eighth costal cartilage was removed and split into 2 pieces to wrap around the reconstruction plate. In our case, the artificial plate wrapped with costal cartilage graft was not exposed and the skin over the plate did not become atrophic over 27 months follow-up even after irradiation. Wrapping around an artificial reconstruction plate with autologous costal cartilage grafts may be more effective than using only a flap covering to prevent exposure of the plate after tumor ablation and radiation therapy.
format Online
Article
Text
id pubmed-5585432
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-55854322017-09-11 Prevention of Mandible Reconstruction Plate Exposure by Costal Cartilage Wrapping Iwasawa, Motonao Mishima, Yoshito Ohtsubo, Miho Plast Reconstr Surg Glob Open Case Report After mandibulectomy in cancer surgery, reconstruction is often performed with a reconstruction plate covered with a soft-tissue free flap in patients in poor condition. However, the rate of complications for mandibular reconstruction is higher with a reconstruction plate than with vascularized bone grafts. We have developed a costal cartilage wrapping method to prevent exposure of the mandible reconstruction plate. The eighth costal cartilage was removed and split into 2 pieces to wrap around the reconstruction plate. In our case, the artificial plate wrapped with costal cartilage graft was not exposed and the skin over the plate did not become atrophic over 27 months follow-up even after irradiation. Wrapping around an artificial reconstruction plate with autologous costal cartilage grafts may be more effective than using only a flap covering to prevent exposure of the plate after tumor ablation and radiation therapy. Wolters Kluwer Health 2017-08-04 /pmc/articles/PMC5585432/ /pubmed/28894659 http://dx.doi.org/10.1097/GOX.0000000000001438 Text en Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of The American Society of Plastic Surgeons. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Case Report
Iwasawa, Motonao
Mishima, Yoshito
Ohtsubo, Miho
Prevention of Mandible Reconstruction Plate Exposure by Costal Cartilage Wrapping
title Prevention of Mandible Reconstruction Plate Exposure by Costal Cartilage Wrapping
title_full Prevention of Mandible Reconstruction Plate Exposure by Costal Cartilage Wrapping
title_fullStr Prevention of Mandible Reconstruction Plate Exposure by Costal Cartilage Wrapping
title_full_unstemmed Prevention of Mandible Reconstruction Plate Exposure by Costal Cartilage Wrapping
title_short Prevention of Mandible Reconstruction Plate Exposure by Costal Cartilage Wrapping
title_sort prevention of mandible reconstruction plate exposure by costal cartilage wrapping
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5585432/
https://www.ncbi.nlm.nih.gov/pubmed/28894659
http://dx.doi.org/10.1097/GOX.0000000000001438
work_keys_str_mv AT iwasawamotonao preventionofmandiblereconstructionplateexposurebycostalcartilagewrapping
AT mishimayoshito preventionofmandiblereconstructionplateexposurebycostalcartilagewrapping
AT ohtsubomiho preventionofmandiblereconstructionplateexposurebycostalcartilagewrapping