Cargando…
The Pattern of Pre-hospital Medical Service Delivery in Iran; a Cross Sectional Study
INTRODUCTION: Pre-hospital emergency systems provide service by Franco-German and Anglo American models. This study was carried out to compare the Iranian emergency medical service (EMS) with the two models regarding timing and equipment. METHODS: In this cross sectional study, response time, scene...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shahid Beheshti University of Medical Sciences
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5585827/ https://www.ncbi.nlm.nih.gov/pubmed/28894773 |
_version_ | 1783261702892027904 |
---|---|
author | Haddadi, Mashyaneh Sarvar, Mohammad Soori, Hamid Ainy, Elaheh |
author_facet | Haddadi, Mashyaneh Sarvar, Mohammad Soori, Hamid Ainy, Elaheh |
author_sort | Haddadi, Mashyaneh |
collection | PubMed |
description | INTRODUCTION: Pre-hospital emergency systems provide service by Franco-German and Anglo American models. This study was carried out to compare the Iranian emergency medical service (EMS) with the two models regarding timing and equipment. METHODS: In this cross sectional study, response time, scene time, and transport time to hospital as well as ambulance equipment of five hundred thousand Tehran EMS recorded missions, during one year, were compared with Franco-German and Anglo American models, trying to determine the pattern of EMS delivery in Iran. RESULTS: The mean response time, scene time, and transport time to hospital were 15.00 ±10.88, 18 ±11.48, and 15.00 ±11.20 minutes, respectively. The mean response time (p<0.035), scene time (p<0.033), and transport time to hospital (p<0.015) were more than the standard time. Percentage of ambulances quipped with automated external defibrillator (45%, p<0.001), ventilator (2%, p<0.001), disposable splint (0%, p<0.001), and wheelchair (0%, p<0.001) were very far from standards. CONCLUSION: The pattern of EMS delivery in Iran was a combination of Anglo American and Franco-German system. |
format | Online Article Text |
id | pubmed-5585827 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Shahid Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-55858272017-09-11 The Pattern of Pre-hospital Medical Service Delivery in Iran; a Cross Sectional Study Haddadi, Mashyaneh Sarvar, Mohammad Soori, Hamid Ainy, Elaheh Emerg (Tehran) Original Article INTRODUCTION: Pre-hospital emergency systems provide service by Franco-German and Anglo American models. This study was carried out to compare the Iranian emergency medical service (EMS) with the two models regarding timing and equipment. METHODS: In this cross sectional study, response time, scene time, and transport time to hospital as well as ambulance equipment of five hundred thousand Tehran EMS recorded missions, during one year, were compared with Franco-German and Anglo American models, trying to determine the pattern of EMS delivery in Iran. RESULTS: The mean response time, scene time, and transport time to hospital were 15.00 ±10.88, 18 ±11.48, and 15.00 ±11.20 minutes, respectively. The mean response time (p<0.035), scene time (p<0.033), and transport time to hospital (p<0.015) were more than the standard time. Percentage of ambulances quipped with automated external defibrillator (45%, p<0.001), ventilator (2%, p<0.001), disposable splint (0%, p<0.001), and wheelchair (0%, p<0.001) were very far from standards. CONCLUSION: The pattern of EMS delivery in Iran was a combination of Anglo American and Franco-German system. Shahid Beheshti University of Medical Sciences 2017 2017-02-19 /pmc/articles/PMC5585827/ /pubmed/28894773 Text en © Copyright (2017) Shahid Beheshti University ofMedical Sciences This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Haddadi, Mashyaneh Sarvar, Mohammad Soori, Hamid Ainy, Elaheh The Pattern of Pre-hospital Medical Service Delivery in Iran; a Cross Sectional Study |
title | The Pattern of Pre-hospital Medical Service Delivery in Iran; a Cross Sectional Study |
title_full | The Pattern of Pre-hospital Medical Service Delivery in Iran; a Cross Sectional Study |
title_fullStr | The Pattern of Pre-hospital Medical Service Delivery in Iran; a Cross Sectional Study |
title_full_unstemmed | The Pattern of Pre-hospital Medical Service Delivery in Iran; a Cross Sectional Study |
title_short | The Pattern of Pre-hospital Medical Service Delivery in Iran; a Cross Sectional Study |
title_sort | pattern of pre-hospital medical service delivery in iran; a cross sectional study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5585827/ https://www.ncbi.nlm.nih.gov/pubmed/28894773 |
work_keys_str_mv | AT haddadimashyaneh thepatternofprehospitalmedicalservicedeliveryiniranacrosssectionalstudy AT sarvarmohammad thepatternofprehospitalmedicalservicedeliveryiniranacrosssectionalstudy AT soorihamid thepatternofprehospitalmedicalservicedeliveryiniranacrosssectionalstudy AT ainyelaheh thepatternofprehospitalmedicalservicedeliveryiniranacrosssectionalstudy AT haddadimashyaneh patternofprehospitalmedicalservicedeliveryiniranacrosssectionalstudy AT sarvarmohammad patternofprehospitalmedicalservicedeliveryiniranacrosssectionalstudy AT soorihamid patternofprehospitalmedicalservicedeliveryiniranacrosssectionalstudy AT ainyelaheh patternofprehospitalmedicalservicedeliveryiniranacrosssectionalstudy |