Safety and Efficacy of the StarClose Vascular Closure System following 8-Fr Sheath Placement for Intra-Aortic Balloon Pump: A Single-Center Analysis of 42 Consecutive Patients
OBJECTIVE: To assess the safety and efficacy of the StarClose device following intra-aortic balloon pump (IABP) counterpulsation using 8-Fr femoral sheaths. SUBJECTS AND METHODS: From June 2008 to August 2012, 42 consecutive patients who received IABP implantation via common femoral artery (CFA) pun...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
S. Karger AG
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5586891/ https://www.ncbi.nlm.nih.gov/pubmed/24776529 http://dx.doi.org/10.1159/000362127 |
_version_ | 1783261899424530432 |
---|---|
author | Chu, Guang Yang, Wenyi Zhang, Guobing Zhang, Zhi Liu, Shaowen Sun, Baogui Wang, Fang |
author_facet | Chu, Guang Yang, Wenyi Zhang, Guobing Zhang, Zhi Liu, Shaowen Sun, Baogui Wang, Fang |
author_sort | Chu, Guang |
collection | PubMed |
description | OBJECTIVE: To assess the safety and efficacy of the StarClose device following intra-aortic balloon pump (IABP) counterpulsation using 8-Fr femoral sheaths. SUBJECTS AND METHODS: From June 2008 to August 2012, 42 consecutive patients who received IABP implantation via common femoral artery (CFA) punctures with an 8-Fr sheath (which were then sealed with the StarClose Vascular Closure System at the bedside) were included in this retrospective single-arm study. All the patients underwent duplex control of the puncture site 24 h after deployment of the device, in order to determine the presence or absence of vascular complications including hematoma, pseudoaneurysm, arteriovenous fistula and arterial/venous thrombosis or stenosis. The safety end points were the vascular complications during the hospital stay, and the efficacy end points included device and procedure success. RESULTS: The procedure success rate was 92.9% (39/42) and the device success rate was 88.1% (37/42). Major vascular complications occurred in 3 (7.1%) patients; 1 developed a massive hematoma >10 cm which was managed by blood transfusion and surgical reconstruction, and the other 2 developed pseudoaneurysm which was cured by ultrasound-guided thrombin injection or manual compression. Minor vascular complications occurred in 5 (11.9%) patients, including blood oozing in 2, hematoma <5 cm in 2 and severe pain in the remaining patient. CONCLUSION: CFA closure with the StarClose device was safe, feasible and effective in patients undergoing IABP support using 8-Fr sheath sizes. |
format | Online Article Text |
id | pubmed-5586891 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | S. Karger AG |
record_format | MEDLINE/PubMed |
spelling | pubmed-55868912017-11-01 Safety and Efficacy of the StarClose Vascular Closure System following 8-Fr Sheath Placement for Intra-Aortic Balloon Pump: A Single-Center Analysis of 42 Consecutive Patients Chu, Guang Yang, Wenyi Zhang, Guobing Zhang, Zhi Liu, Shaowen Sun, Baogui Wang, Fang Med Princ Pract Original Paper OBJECTIVE: To assess the safety and efficacy of the StarClose device following intra-aortic balloon pump (IABP) counterpulsation using 8-Fr femoral sheaths. SUBJECTS AND METHODS: From June 2008 to August 2012, 42 consecutive patients who received IABP implantation via common femoral artery (CFA) punctures with an 8-Fr sheath (which were then sealed with the StarClose Vascular Closure System at the bedside) were included in this retrospective single-arm study. All the patients underwent duplex control of the puncture site 24 h after deployment of the device, in order to determine the presence or absence of vascular complications including hematoma, pseudoaneurysm, arteriovenous fistula and arterial/venous thrombosis or stenosis. The safety end points were the vascular complications during the hospital stay, and the efficacy end points included device and procedure success. RESULTS: The procedure success rate was 92.9% (39/42) and the device success rate was 88.1% (37/42). Major vascular complications occurred in 3 (7.1%) patients; 1 developed a massive hematoma >10 cm which was managed by blood transfusion and surgical reconstruction, and the other 2 developed pseudoaneurysm which was cured by ultrasound-guided thrombin injection or manual compression. Minor vascular complications occurred in 5 (11.9%) patients, including blood oozing in 2, hematoma <5 cm in 2 and severe pain in the remaining patient. CONCLUSION: CFA closure with the StarClose device was safe, feasible and effective in patients undergoing IABP support using 8-Fr sheath sizes. S. Karger AG 2014-07 2014-04-23 /pmc/articles/PMC5586891/ /pubmed/24776529 http://dx.doi.org/10.1159/000362127 Text en Copyright © 2014 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported license (CC BY-NC) (www.karger.com/OA-license), applicable to the online version of the article only. Distribution permitted for non-commercial purposes only. |
spellingShingle | Original Paper Chu, Guang Yang, Wenyi Zhang, Guobing Zhang, Zhi Liu, Shaowen Sun, Baogui Wang, Fang Safety and Efficacy of the StarClose Vascular Closure System following 8-Fr Sheath Placement for Intra-Aortic Balloon Pump: A Single-Center Analysis of 42 Consecutive Patients |
title | Safety and Efficacy of the StarClose Vascular Closure System following 8-Fr Sheath Placement for Intra-Aortic Balloon Pump: A Single-Center Analysis of 42 Consecutive Patients |
title_full | Safety and Efficacy of the StarClose Vascular Closure System following 8-Fr Sheath Placement for Intra-Aortic Balloon Pump: A Single-Center Analysis of 42 Consecutive Patients |
title_fullStr | Safety and Efficacy of the StarClose Vascular Closure System following 8-Fr Sheath Placement for Intra-Aortic Balloon Pump: A Single-Center Analysis of 42 Consecutive Patients |
title_full_unstemmed | Safety and Efficacy of the StarClose Vascular Closure System following 8-Fr Sheath Placement for Intra-Aortic Balloon Pump: A Single-Center Analysis of 42 Consecutive Patients |
title_short | Safety and Efficacy of the StarClose Vascular Closure System following 8-Fr Sheath Placement for Intra-Aortic Balloon Pump: A Single-Center Analysis of 42 Consecutive Patients |
title_sort | safety and efficacy of the starclose vascular closure system following 8-fr sheath placement for intra-aortic balloon pump: a single-center analysis of 42 consecutive patients |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5586891/ https://www.ncbi.nlm.nih.gov/pubmed/24776529 http://dx.doi.org/10.1159/000362127 |
work_keys_str_mv | AT chuguang safetyandefficacyofthestarclosevascularclosuresystemfollowing8frsheathplacementforintraaorticballoonpumpasinglecenteranalysisof42consecutivepatients AT yangwenyi safetyandefficacyofthestarclosevascularclosuresystemfollowing8frsheathplacementforintraaorticballoonpumpasinglecenteranalysisof42consecutivepatients AT zhangguobing safetyandefficacyofthestarclosevascularclosuresystemfollowing8frsheathplacementforintraaorticballoonpumpasinglecenteranalysisof42consecutivepatients AT zhangzhi safetyandefficacyofthestarclosevascularclosuresystemfollowing8frsheathplacementforintraaorticballoonpumpasinglecenteranalysisof42consecutivepatients AT liushaowen safetyandefficacyofthestarclosevascularclosuresystemfollowing8frsheathplacementforintraaorticballoonpumpasinglecenteranalysisof42consecutivepatients AT sunbaogui safetyandefficacyofthestarclosevascularclosuresystemfollowing8frsheathplacementforintraaorticballoonpumpasinglecenteranalysisof42consecutivepatients AT wangfang safetyandefficacyofthestarclosevascularclosuresystemfollowing8frsheathplacementforintraaorticballoonpumpasinglecenteranalysisof42consecutivepatients |