Cargando…

Plasma Omentin-1 Level as a Predictor of Good Coronary Collateral Circulation

Aims: Coronary collateral circulation (CCC) is crucial during an acute ischemic attack. Evidences showed that omentin-1 exhibited remarkable antiatherogenic effects and ischemia-induced revascularization. The aim of this study was to investigate the relationship between plasma omentin-1 levels and C...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Ji-Peng, Tong, Xiao-Yu, Zhu, Ling-Ping, Luo, Jing-Min, Luo, Ying, Bai, Yong-Ping, Li, Chuan-Chang, Zhang, Guo-Gang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japan Atherosclerosis Society 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5587520/
https://www.ncbi.nlm.nih.gov/pubmed/28123148
http://dx.doi.org/10.5551/jat.37440
_version_ 1783261998870429696
author Zhou, Ji-Peng
Tong, Xiao-Yu
Zhu, Ling-Ping
Luo, Jing-Min
Luo, Ying
Bai, Yong-Ping
Li, Chuan-Chang
Zhang, Guo-Gang
author_facet Zhou, Ji-Peng
Tong, Xiao-Yu
Zhu, Ling-Ping
Luo, Jing-Min
Luo, Ying
Bai, Yong-Ping
Li, Chuan-Chang
Zhang, Guo-Gang
author_sort Zhou, Ji-Peng
collection PubMed
description Aims: Coronary collateral circulation (CCC) is crucial during an acute ischemic attack. Evidences showed that omentin-1 exhibited remarkable antiatherogenic effects and ischemia-induced revascularization. The aim of this study was to investigate the relationship between plasma omentin-1 levels and CCC in patients with ≥ 90% angiography-proven coronary occlusion. Methods: 142 patients with ≥ 90% luminal diameter stenosis in at least one major epicardial coronary artery were recruited. Among them, 79 patients with Rentrop 0–1 grade were classified into the poor CCC group and 63 patients with Rentrop 2–3 grade were included into the good CCC group. The association between plasma omentin-1 levels and CCC status was assessed. Results: Plasma omentin-1 level was significantly higher in patients with good CCC than those with poor CCC (566.57 ± 26.90 vs. 492.38 ± 19.70 ng/mL, p = 0.024). Besides, omentin-1 was positively correlated with total cholesterol (TC), high-density lipoprotein, and gensini score but inversely with hyperlipidemia and body mass index (all p values < 0.05). Multivariate regression analysis indicated that omentin-1 [odds ratio (OR) = 1.002, 95% confidence interval (CI): 1.000 – 1.004, p = 0.041)], TC, the number of the diseased vessels, a higher frequency of left circumflex artery and right coronary artery, chronic total occlusion, and gensini score remained as the independent predictors of good CCC. Conclusion: Higher plasma omentin-1 level was associated with better CCC development. Our findings suggest that omentin-1 may be an alternative marker for adequate CCC in patients with ≥ 90% coronary occlusion.
format Online
Article
Text
id pubmed-5587520
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Japan Atherosclerosis Society
record_format MEDLINE/PubMed
spelling pubmed-55875202017-09-11 Plasma Omentin-1 Level as a Predictor of Good Coronary Collateral Circulation Zhou, Ji-Peng Tong, Xiao-Yu Zhu, Ling-Ping Luo, Jing-Min Luo, Ying Bai, Yong-Ping Li, Chuan-Chang Zhang, Guo-Gang J Atheroscler Thromb Original Article Aims: Coronary collateral circulation (CCC) is crucial during an acute ischemic attack. Evidences showed that omentin-1 exhibited remarkable antiatherogenic effects and ischemia-induced revascularization. The aim of this study was to investigate the relationship between plasma omentin-1 levels and CCC in patients with ≥ 90% angiography-proven coronary occlusion. Methods: 142 patients with ≥ 90% luminal diameter stenosis in at least one major epicardial coronary artery were recruited. Among them, 79 patients with Rentrop 0–1 grade were classified into the poor CCC group and 63 patients with Rentrop 2–3 grade were included into the good CCC group. The association between plasma omentin-1 levels and CCC status was assessed. Results: Plasma omentin-1 level was significantly higher in patients with good CCC than those with poor CCC (566.57 ± 26.90 vs. 492.38 ± 19.70 ng/mL, p = 0.024). Besides, omentin-1 was positively correlated with total cholesterol (TC), high-density lipoprotein, and gensini score but inversely with hyperlipidemia and body mass index (all p values < 0.05). Multivariate regression analysis indicated that omentin-1 [odds ratio (OR) = 1.002, 95% confidence interval (CI): 1.000 – 1.004, p = 0.041)], TC, the number of the diseased vessels, a higher frequency of left circumflex artery and right coronary artery, chronic total occlusion, and gensini score remained as the independent predictors of good CCC. Conclusion: Higher plasma omentin-1 level was associated with better CCC development. Our findings suggest that omentin-1 may be an alternative marker for adequate CCC in patients with ≥ 90% coronary occlusion. Japan Atherosclerosis Society 2017-09-01 /pmc/articles/PMC5587520/ /pubmed/28123148 http://dx.doi.org/10.5551/jat.37440 Text en 2017 Japan Atherosclerosis Society This article is distributed under the terms of the latest version of CC BY-NC-SA defined by the Creative Commons Attribution License.http://creativecommons.org/licenses/by-nc-sa/3.0/
spellingShingle Original Article
Zhou, Ji-Peng
Tong, Xiao-Yu
Zhu, Ling-Ping
Luo, Jing-Min
Luo, Ying
Bai, Yong-Ping
Li, Chuan-Chang
Zhang, Guo-Gang
Plasma Omentin-1 Level as a Predictor of Good Coronary Collateral Circulation
title Plasma Omentin-1 Level as a Predictor of Good Coronary Collateral Circulation
title_full Plasma Omentin-1 Level as a Predictor of Good Coronary Collateral Circulation
title_fullStr Plasma Omentin-1 Level as a Predictor of Good Coronary Collateral Circulation
title_full_unstemmed Plasma Omentin-1 Level as a Predictor of Good Coronary Collateral Circulation
title_short Plasma Omentin-1 Level as a Predictor of Good Coronary Collateral Circulation
title_sort plasma omentin-1 level as a predictor of good coronary collateral circulation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5587520/
https://www.ncbi.nlm.nih.gov/pubmed/28123148
http://dx.doi.org/10.5551/jat.37440
work_keys_str_mv AT zhoujipeng plasmaomentin1levelasapredictorofgoodcoronarycollateralcirculation
AT tongxiaoyu plasmaomentin1levelasapredictorofgoodcoronarycollateralcirculation
AT zhulingping plasmaomentin1levelasapredictorofgoodcoronarycollateralcirculation
AT luojingmin plasmaomentin1levelasapredictorofgoodcoronarycollateralcirculation
AT luoying plasmaomentin1levelasapredictorofgoodcoronarycollateralcirculation
AT baiyongping plasmaomentin1levelasapredictorofgoodcoronarycollateralcirculation
AT lichuanchang plasmaomentin1levelasapredictorofgoodcoronarycollateralcirculation
AT zhangguogang plasmaomentin1levelasapredictorofgoodcoronarycollateralcirculation