Cargando…

Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields

The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: th...

Descripción completa

Detalles Bibliográficos
Autores principales: Ben Daya, Ibrahim, Chen, Albert I. H., Shafiee, Mohammad Javad, Wong, Alexander, Yeow, John T. W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5587655/
https://www.ncbi.nlm.nih.gov/pubmed/28878344
http://dx.doi.org/10.1038/s41598-017-09534-1
_version_ 1783262030334001152
author Ben Daya, Ibrahim
Chen, Albert I. H.
Shafiee, Mohammad Javad
Wong, Alexander
Yeow, John T. W.
author_facet Ben Daya, Ibrahim
Chen, Albert I. H.
Shafiee, Mohammad Javad
Wong, Alexander
Yeow, John T. W.
author_sort Ben Daya, Ibrahim
collection PubMed
description The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account when building a reconstruction framework. In this research, we build on a previously published system and propose an edge-guided, compensated row-column ultrasound imaging system that incorporates multilayered edge-guided stochastically fully connected conditional random fields to address the limitations of the row-column method. Tests carried out on simulated and real row-column ultrasound images show the effectiveness of our proposed system over other published systems. Visual assessment show our proposed system’s potential at preserving edges and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal-to-Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.
format Online
Article
Text
id pubmed-5587655
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-55876552017-09-13 Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields Ben Daya, Ibrahim Chen, Albert I. H. Shafiee, Mohammad Javad Wong, Alexander Yeow, John T. W. Sci Rep Article The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account when building a reconstruction framework. In this research, we build on a previously published system and propose an edge-guided, compensated row-column ultrasound imaging system that incorporates multilayered edge-guided stochastically fully connected conditional random fields to address the limitations of the row-column method. Tests carried out on simulated and real row-column ultrasound images show the effectiveness of our proposed system over other published systems. Visual assessment show our proposed system’s potential at preserving edges and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal-to-Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging. Nature Publishing Group UK 2017-09-06 /pmc/articles/PMC5587655/ /pubmed/28878344 http://dx.doi.org/10.1038/s41598-017-09534-1 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Ben Daya, Ibrahim
Chen, Albert I. H.
Shafiee, Mohammad Javad
Wong, Alexander
Yeow, John T. W.
Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields
title Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields
title_full Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields
title_fullStr Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields
title_full_unstemmed Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields
title_short Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields
title_sort compensated row-column ultrasound imaging system using multilayered edge guided stochastically fully connected random fields
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5587655/
https://www.ncbi.nlm.nih.gov/pubmed/28878344
http://dx.doi.org/10.1038/s41598-017-09534-1
work_keys_str_mv AT bendayaibrahim compensatedrowcolumnultrasoundimagingsystemusingmultilayerededgeguidedstochasticallyfullyconnectedrandomfields
AT chenalbertih compensatedrowcolumnultrasoundimagingsystemusingmultilayerededgeguidedstochasticallyfullyconnectedrandomfields
AT shafieemohammadjavad compensatedrowcolumnultrasoundimagingsystemusingmultilayerededgeguidedstochasticallyfullyconnectedrandomfields
AT wongalexander compensatedrowcolumnultrasoundimagingsystemusingmultilayerededgeguidedstochasticallyfullyconnectedrandomfields
AT yeowjohntw compensatedrowcolumnultrasoundimagingsystemusingmultilayerededgeguidedstochasticallyfullyconnectedrandomfields