Cargando…

Robot-Assisted Laparoscopic Repair of Extraperitoneal Ureteral Inguinal Hernia with Mesh Placement

Background: Ureter involvement within indirect hernias is a rare phenomenon usually identified incidentally during herniorrhaphy. Even more rare are extraperitoneal ureteral inguinal hernias, which represent about 20% of these cases and are characterized by a substantial amount of extraperitoneal fa...

Descripción completa

Detalles Bibliográficos
Autores principales: Pucheril, Daniel, Chun, Brian, Dalela, Deepansh, Abdollah, Firas, Laker, Scott A., Rogers, Craig G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mary Ann Liebert, Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5587904/
https://www.ncbi.nlm.nih.gov/pubmed/28894843
http://dx.doi.org/10.1089/cren.2017.0046
_version_ 1783262082106392576
author Pucheril, Daniel
Chun, Brian
Dalela, Deepansh
Abdollah, Firas
Laker, Scott A.
Rogers, Craig G.
author_facet Pucheril, Daniel
Chun, Brian
Dalela, Deepansh
Abdollah, Firas
Laker, Scott A.
Rogers, Craig G.
author_sort Pucheril, Daniel
collection PubMed
description Background: Ureter involvement within indirect hernias is a rare phenomenon usually identified incidentally during herniorrhaphy. Even more rare are extraperitoneal ureteral inguinal hernias, which represent about 20% of these cases and are characterized by a substantial amount of extraperitoneal fat in the hernia defect, the absence of a peritoneal sac, and associated with hydroureteronephrosis and nephroptosis. To date, repair of ureteral inguinal hernias has been performed exclusively using open surgical techniques. We report the first case of successful robot-assisted laparoscopic repair of this rare presentation. Case Presentation: A morbidly obese 70-year-old male with an unremarkable surgical and urological history presents with a 15-year history of nonpainful, enlarging right scrotal swelling measuring 25 cm in diameter. CT imaging revealed right nephroptosis and a hernia defect containing a dilated right ureter looping into the scrotum surrounded by significant extraperitoneal fat. Retrograde pyelography and ureteral catheter placement confirmed a >100 cm ureter. The patient underwent a robot-assisted laparoscopic repair. The inferior epigastric artery, spermatic cord vessels, vas deferens, and ureter were identified. The defect was reduced using external scrotal pressure and reinforced with ProGrip™ self-fixating laparoscopic mesh. The patient was discharged 2 days later following an uneventful postoperative course. Conclusion: Although rare and usually incidentally discovered, extraperitoneal ureteral inguinal hernias can be identified preoperatively by the astute clinician. Preoperative identification allows for improved surgical planning, including a minimally invasive approach. Robot-assisted laparoscopic repair with mesh placement is a feasible alternative to traditional open techniques.
format Online
Article
Text
id pubmed-5587904
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Mary Ann Liebert, Inc.
record_format MEDLINE/PubMed
spelling pubmed-55879042017-09-11 Robot-Assisted Laparoscopic Repair of Extraperitoneal Ureteral Inguinal Hernia with Mesh Placement Pucheril, Daniel Chun, Brian Dalela, Deepansh Abdollah, Firas Laker, Scott A. Rogers, Craig G. J Endourol Case Rep Case Report Background: Ureter involvement within indirect hernias is a rare phenomenon usually identified incidentally during herniorrhaphy. Even more rare are extraperitoneal ureteral inguinal hernias, which represent about 20% of these cases and are characterized by a substantial amount of extraperitoneal fat in the hernia defect, the absence of a peritoneal sac, and associated with hydroureteronephrosis and nephroptosis. To date, repair of ureteral inguinal hernias has been performed exclusively using open surgical techniques. We report the first case of successful robot-assisted laparoscopic repair of this rare presentation. Case Presentation: A morbidly obese 70-year-old male with an unremarkable surgical and urological history presents with a 15-year history of nonpainful, enlarging right scrotal swelling measuring 25 cm in diameter. CT imaging revealed right nephroptosis and a hernia defect containing a dilated right ureter looping into the scrotum surrounded by significant extraperitoneal fat. Retrograde pyelography and ureteral catheter placement confirmed a >100 cm ureter. The patient underwent a robot-assisted laparoscopic repair. The inferior epigastric artery, spermatic cord vessels, vas deferens, and ureter were identified. The defect was reduced using external scrotal pressure and reinforced with ProGrip™ self-fixating laparoscopic mesh. The patient was discharged 2 days later following an uneventful postoperative course. Conclusion: Although rare and usually incidentally discovered, extraperitoneal ureteral inguinal hernias can be identified preoperatively by the astute clinician. Preoperative identification allows for improved surgical planning, including a minimally invasive approach. Robot-assisted laparoscopic repair with mesh placement is a feasible alternative to traditional open techniques. Mary Ann Liebert, Inc. 2017-07-01 /pmc/articles/PMC5587904/ /pubmed/28894843 http://dx.doi.org/10.1089/cren.2017.0046 Text en © Daniel Pucheril et al. 2017; Published by Mary Ann Liebert, Inc. This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Pucheril, Daniel
Chun, Brian
Dalela, Deepansh
Abdollah, Firas
Laker, Scott A.
Rogers, Craig G.
Robot-Assisted Laparoscopic Repair of Extraperitoneal Ureteral Inguinal Hernia with Mesh Placement
title Robot-Assisted Laparoscopic Repair of Extraperitoneal Ureteral Inguinal Hernia with Mesh Placement
title_full Robot-Assisted Laparoscopic Repair of Extraperitoneal Ureteral Inguinal Hernia with Mesh Placement
title_fullStr Robot-Assisted Laparoscopic Repair of Extraperitoneal Ureteral Inguinal Hernia with Mesh Placement
title_full_unstemmed Robot-Assisted Laparoscopic Repair of Extraperitoneal Ureteral Inguinal Hernia with Mesh Placement
title_short Robot-Assisted Laparoscopic Repair of Extraperitoneal Ureteral Inguinal Hernia with Mesh Placement
title_sort robot-assisted laparoscopic repair of extraperitoneal ureteral inguinal hernia with mesh placement
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5587904/
https://www.ncbi.nlm.nih.gov/pubmed/28894843
http://dx.doi.org/10.1089/cren.2017.0046
work_keys_str_mv AT pucherildaniel robotassistedlaparoscopicrepairofextraperitonealureteralinguinalherniawithmeshplacement
AT chunbrian robotassistedlaparoscopicrepairofextraperitonealureteralinguinalherniawithmeshplacement
AT daleladeepansh robotassistedlaparoscopicrepairofextraperitonealureteralinguinalherniawithmeshplacement
AT abdollahfiras robotassistedlaparoscopicrepairofextraperitonealureteralinguinalherniawithmeshplacement
AT lakerscotta robotassistedlaparoscopicrepairofextraperitonealureteralinguinalherniawithmeshplacement
AT rogerscraigg robotassistedlaparoscopicrepairofextraperitonealureteralinguinalherniawithmeshplacement