Cargando…

Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc

OBJECTIVE: To evaluate a home-built Java-based program (GFRcalc) to simplify the calculation of glomerular filtration rate (GFR) after administration of chromium-51 ethylenediaminetetraacetic acid ((51)Cr-EDTA) for routine clinical use. MATERIALS AND METHODS: In the program GFRcalc, the GFR was calc...

Descripción completa

Detalles Bibliográficos
Autores principales: Geist, Barbara Katharina, Diemling, Markus, Staudenherz, Anton
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5588420/
https://www.ncbi.nlm.nih.gov/pubmed/26925969
http://dx.doi.org/10.1159/000445028
_version_ 1783262170030538752
author Geist, Barbara Katharina
Diemling, Markus
Staudenherz, Anton
author_facet Geist, Barbara Katharina
Diemling, Markus
Staudenherz, Anton
author_sort Geist, Barbara Katharina
collection PubMed
description OBJECTIVE: To evaluate a home-built Java-based program (GFRcalc) to simplify the calculation of glomerular filtration rate (GFR) after administration of chromium-51 ethylenediaminetetraacetic acid ((51)Cr-EDTA) for routine clinical use. MATERIALS AND METHODS: In the program GFRcalc, the GFR was calculated based on the biological half-life of the (51)Cr-EDTA concentration using the slope-intercept method of between two and five blood samples. Additional features included the ability to export patient data and generate clinical reports as well as to calculate the error of the fit of the GFR measurement in cases with three or more blood samples collected. The GFR was calculated from one, two and three blood samples of 133 patients with body surface-corrected GFR of 21-213 ml/min/1.73 m(2). The Pearson correlation coefficient and the error of the fit for the GFR measurement were calculated for the three-sample method. RESULTS: The correlation coefficient for the three-sample method and the fit error correlated well for small fit errors; in case of fit errors >10%, the correlation coefficient partially differed in results compared to the other methods. The three-sample GFR values differed by approximately 17% from the single-sample GFRs. The fit errors of the three-sample GFRs correlated (r = 0.57) with their difference from the two-sample GFRs. CONCLUSION: In this study, the fit error that GFRcalc provided for the three-sample GFR offered a simple and reliable method to check the results obtained. This could also allow physicians to assess the reliability of the results and base their decisions on the quality of the measurement.
format Online
Article
Text
id pubmed-5588420
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-55884202017-11-01 Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc Geist, Barbara Katharina Diemling, Markus Staudenherz, Anton Med Princ Pract Original Paper OBJECTIVE: To evaluate a home-built Java-based program (GFRcalc) to simplify the calculation of glomerular filtration rate (GFR) after administration of chromium-51 ethylenediaminetetraacetic acid ((51)Cr-EDTA) for routine clinical use. MATERIALS AND METHODS: In the program GFRcalc, the GFR was calculated based on the biological half-life of the (51)Cr-EDTA concentration using the slope-intercept method of between two and five blood samples. Additional features included the ability to export patient data and generate clinical reports as well as to calculate the error of the fit of the GFR measurement in cases with three or more blood samples collected. The GFR was calculated from one, two and three blood samples of 133 patients with body surface-corrected GFR of 21-213 ml/min/1.73 m(2). The Pearson correlation coefficient and the error of the fit for the GFR measurement were calculated for the three-sample method. RESULTS: The correlation coefficient for the three-sample method and the fit error correlated well for small fit errors; in case of fit errors >10%, the correlation coefficient partially differed in results compared to the other methods. The three-sample GFR values differed by approximately 17% from the single-sample GFRs. The fit errors of the three-sample GFRs correlated (r = 0.57) with their difference from the two-sample GFRs. CONCLUSION: In this study, the fit error that GFRcalc provided for the three-sample GFR offered a simple and reliable method to check the results obtained. This could also allow physicians to assess the reliability of the results and base their decisions on the quality of the measurement. S. Karger AG 2016-06 2016-02-29 /pmc/articles/PMC5588420/ /pubmed/26925969 http://dx.doi.org/10.1159/000445028 Text en Copyright © 2016 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported license (CC BY-NC) (www.karger.com/OA-license), applicable to the online version of the article only. Distribution permitted for non-commercial purposes only.
spellingShingle Original Paper
Geist, Barbara Katharina
Diemling, Markus
Staudenherz, Anton
Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc
title Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc
title_full Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc
title_fullStr Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc
title_full_unstemmed Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc
title_short Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc
title_sort glomerular filtration rate and error calculation based on the slope-intercept method with chromium-51 ethylenediaminetetraacetic acid via a new clinical software: gfrcalc
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5588420/
https://www.ncbi.nlm.nih.gov/pubmed/26925969
http://dx.doi.org/10.1159/000445028
work_keys_str_mv AT geistbarbarakatharina glomerularfiltrationrateanderrorcalculationbasedontheslopeinterceptmethodwithchromium51ethylenediaminetetraaceticacidviaanewclinicalsoftwaregfrcalc
AT diemlingmarkus glomerularfiltrationrateanderrorcalculationbasedontheslopeinterceptmethodwithchromium51ethylenediaminetetraaceticacidviaanewclinicalsoftwaregfrcalc
AT staudenherzanton glomerularfiltrationrateanderrorcalculationbasedontheslopeinterceptmethodwithchromium51ethylenediaminetetraaceticacidviaanewclinicalsoftwaregfrcalc