Cargando…
Effect of Double Filtration Plasmapheresis on Various Plasma Components and Patient Safety: A Prospective Observational Cohort Study
Double filtration plasmapheresis (DFPP) was historically used for blood group incompatible renal transplantation. Very few studies are available worldwide regarding its efficiency in removing specific plasma components, and safety. We conducted a prospective observational cohort study over 1 year on...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5590415/ https://www.ncbi.nlm.nih.gov/pubmed/28904434 http://dx.doi.org/10.4103/ijn.IJN_64_17 |
_version_ | 1783262533757435904 |
---|---|
author | Jagdish, K. Jacob, S. Varughese, S. David, V. G. Mohapatra, A. Valson, A. Tulsidas, K. Veerasami, T. Alexander, S. |
author_facet | Jagdish, K. Jacob, S. Varughese, S. David, V. G. Mohapatra, A. Valson, A. Tulsidas, K. Veerasami, T. Alexander, S. |
author_sort | Jagdish, K. |
collection | PubMed |
description | Double filtration plasmapheresis (DFPP) was historically used for blood group incompatible renal transplantation. Very few studies are available worldwide regarding its efficiency in removing specific plasma components, and safety. We conducted a prospective observational cohort study over 1 year on patients undergoing DFPP for various renal indications. There were 15 patients with 39 sessions. The pre- and post-procedure plasma samples of serum IgG, IgA, IgM, fibrinogen, calcium, phosphate, potassium, and magnesium were analyzed. The effluent albumin concentration was also measured, and complications during the hospital stay were recorded. Cumulative removal of serum IgG, IgA, IgM, fibrinogen, and albumin at the end of four sessions were 72%, 89%, 96%, 88.5%, and 21.3%, respectively and effluent albumin concentration was 1.75 – 2.0 times (range: 6.3 g/dl – 7.2 g/dl; mean ± standard deviation (SD) – 7 g/dl ± 0.3 g/dl) the preprocedural serum albumin (mean ± SD – 3.5 g/dl ± 0.5 g/dl). Removal of other plasma components were not statistically significant. Hypotensive episodes were observed only 16.6%, with the usage of effluent concentration albumin as replacement fluid despite an average 2.4 (mean ± SD – 2.4 ± 0.4 l) liters of plasma volume processing each session. DFPP removes IgG, IgA, IgM, fibrinogen, and albumin. The cumulative removal IgG (72%) is suboptimal, whereas IgA (89%) and IgM (96%) are comparable to historical controls. We observed lesser episodes (12.5%) of hypotension with effluent albumin concentration as replacement fluid, and all bleeding complications were observed when serum fibrinogen level was <50 mg/dl. |
format | Online Article Text |
id | pubmed-5590415 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-55904152017-09-13 Effect of Double Filtration Plasmapheresis on Various Plasma Components and Patient Safety: A Prospective Observational Cohort Study Jagdish, K. Jacob, S. Varughese, S. David, V. G. Mohapatra, A. Valson, A. Tulsidas, K. Veerasami, T. Alexander, S. Indian J Nephrol Original Article Double filtration plasmapheresis (DFPP) was historically used for blood group incompatible renal transplantation. Very few studies are available worldwide regarding its efficiency in removing specific plasma components, and safety. We conducted a prospective observational cohort study over 1 year on patients undergoing DFPP for various renal indications. There were 15 patients with 39 sessions. The pre- and post-procedure plasma samples of serum IgG, IgA, IgM, fibrinogen, calcium, phosphate, potassium, and magnesium were analyzed. The effluent albumin concentration was also measured, and complications during the hospital stay were recorded. Cumulative removal of serum IgG, IgA, IgM, fibrinogen, and albumin at the end of four sessions were 72%, 89%, 96%, 88.5%, and 21.3%, respectively and effluent albumin concentration was 1.75 – 2.0 times (range: 6.3 g/dl – 7.2 g/dl; mean ± standard deviation (SD) – 7 g/dl ± 0.3 g/dl) the preprocedural serum albumin (mean ± SD – 3.5 g/dl ± 0.5 g/dl). Removal of other plasma components were not statistically significant. Hypotensive episodes were observed only 16.6%, with the usage of effluent concentration albumin as replacement fluid despite an average 2.4 (mean ± SD – 2.4 ± 0.4 l) liters of plasma volume processing each session. DFPP removes IgG, IgA, IgM, fibrinogen, and albumin. The cumulative removal IgG (72%) is suboptimal, whereas IgA (89%) and IgM (96%) are comparable to historical controls. We observed lesser episodes (12.5%) of hypotension with effluent albumin concentration as replacement fluid, and all bleeding complications were observed when serum fibrinogen level was <50 mg/dl. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5590415/ /pubmed/28904434 http://dx.doi.org/10.4103/ijn.IJN_64_17 Text en Copyright: © 2017 Indian Journal of Nephrology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Jagdish, K. Jacob, S. Varughese, S. David, V. G. Mohapatra, A. Valson, A. Tulsidas, K. Veerasami, T. Alexander, S. Effect of Double Filtration Plasmapheresis on Various Plasma Components and Patient Safety: A Prospective Observational Cohort Study |
title | Effect of Double Filtration Plasmapheresis on Various Plasma Components and Patient Safety: A Prospective Observational Cohort Study |
title_full | Effect of Double Filtration Plasmapheresis on Various Plasma Components and Patient Safety: A Prospective Observational Cohort Study |
title_fullStr | Effect of Double Filtration Plasmapheresis on Various Plasma Components and Patient Safety: A Prospective Observational Cohort Study |
title_full_unstemmed | Effect of Double Filtration Plasmapheresis on Various Plasma Components and Patient Safety: A Prospective Observational Cohort Study |
title_short | Effect of Double Filtration Plasmapheresis on Various Plasma Components and Patient Safety: A Prospective Observational Cohort Study |
title_sort | effect of double filtration plasmapheresis on various plasma components and patient safety: a prospective observational cohort study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5590415/ https://www.ncbi.nlm.nih.gov/pubmed/28904434 http://dx.doi.org/10.4103/ijn.IJN_64_17 |
work_keys_str_mv | AT jagdishk effectofdoublefiltrationplasmapheresisonvariousplasmacomponentsandpatientsafetyaprospectiveobservationalcohortstudy AT jacobs effectofdoublefiltrationplasmapheresisonvariousplasmacomponentsandpatientsafetyaprospectiveobservationalcohortstudy AT varugheses effectofdoublefiltrationplasmapheresisonvariousplasmacomponentsandpatientsafetyaprospectiveobservationalcohortstudy AT davidvg effectofdoublefiltrationplasmapheresisonvariousplasmacomponentsandpatientsafetyaprospectiveobservationalcohortstudy AT mohapatraa effectofdoublefiltrationplasmapheresisonvariousplasmacomponentsandpatientsafetyaprospectiveobservationalcohortstudy AT valsona effectofdoublefiltrationplasmapheresisonvariousplasmacomponentsandpatientsafetyaprospectiveobservationalcohortstudy AT tulsidask effectofdoublefiltrationplasmapheresisonvariousplasmacomponentsandpatientsafetyaprospectiveobservationalcohortstudy AT veerasamit effectofdoublefiltrationplasmapheresisonvariousplasmacomponentsandpatientsafetyaprospectiveobservationalcohortstudy AT alexanders effectofdoublefiltrationplasmapheresisonvariousplasmacomponentsandpatientsafetyaprospectiveobservationalcohortstudy |