Cargando…
Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty
This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA). After diagnosing a fracture...
Autores principales: | Peters, Rinne M., Willemse, Pax, Rijk, Paul C., Hoogendoorn, Mels, Zijlstra, Wierd P. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5591987/ https://www.ncbi.nlm.nih.gov/pubmed/28929003 http://dx.doi.org/10.1155/2017/9123684 |
Ejemplares similares
-
Pseudotumours, cobalt and clinical outcome in small head
metal-on-metal versus conventional metal-on-polyethylene total hip
arthroplasty
por: van der Veen, Hugo C, et al.
Publicado: (2019) -
The effect of bearing type on the outcome of total hip arthroplasty: Analysis of 209,912 primary total hip arthroplasties registered in the Dutch Arthroplasty Register
por: Peters, Rinne M, et al.
Publicado: (2018) -
Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial
por: Zijlstra, Wierd P, et al.
Publicado: (2008) -
To mix or not to mix? Medicolegal implications of mixed components in total hip arthroplasty
por: Peters, Rinne M, et al.
Publicado: (2020) -
Similar revision rate after cemented and cementless femoral revisions for periprosthetic femoral fractures in total hip arthroplasty: analysis of 1,879 revision hip arthroplasties in the Dutch Arthroplasty Register
por: VAN DOOREN, Bart, et al.
Publicado: (2023)