Cargando…

Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images

A new method for automatic optic disc localization and segmentation is presented. The localization procedure combines vascular and brightness information to provide the best estimate of the optic disc center which is the starting point for the segmentation algorithm. A detection rate of 99.58% and 1...

Descripción completa

Detalles Bibliográficos
Autores principales: Sigut, Jose, Nunez, Omar, Fumero, Francisco, Gonzalez, Marta, Arnay, Rafael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5592085/
https://www.ncbi.nlm.nih.gov/pubmed/28894642
http://dx.doi.org/10.7717/peerj.3763
_version_ 1783262835225133056
author Sigut, Jose
Nunez, Omar
Fumero, Francisco
Gonzalez, Marta
Arnay, Rafael
author_facet Sigut, Jose
Nunez, Omar
Fumero, Francisco
Gonzalez, Marta
Arnay, Rafael
author_sort Sigut, Jose
collection PubMed
description A new method for automatic optic disc localization and segmentation is presented. The localization procedure combines vascular and brightness information to provide the best estimate of the optic disc center which is the starting point for the segmentation algorithm. A detection rate of 99.58% and 100% was achieved for the Messidor and ONHSD databases, respectively. A simple circular approximation to the optic disc boundary is proposed based on the maximum average contrast between the inner and outer ring of a circle centered on the estimated location. An average overlap coefficient of 0.890 and 0.865 was achieved for the same datasets, outperforming other state of the art methods. The results obtained confirm the advantages of using a simple circular model under non-ideal conditions as opposed to more complex deformable models.
format Online
Article
Text
id pubmed-5592085
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-55920852017-09-11 Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images Sigut, Jose Nunez, Omar Fumero, Francisco Gonzalez, Marta Arnay, Rafael PeerJ Ophthalmology A new method for automatic optic disc localization and segmentation is presented. The localization procedure combines vascular and brightness information to provide the best estimate of the optic disc center which is the starting point for the segmentation algorithm. A detection rate of 99.58% and 100% was achieved for the Messidor and ONHSD databases, respectively. A simple circular approximation to the optic disc boundary is proposed based on the maximum average contrast between the inner and outer ring of a circle centered on the estimated location. An average overlap coefficient of 0.890 and 0.865 was achieved for the same datasets, outperforming other state of the art methods. The results obtained confirm the advantages of using a simple circular model under non-ideal conditions as opposed to more complex deformable models. PeerJ Inc. 2017-09-07 /pmc/articles/PMC5592085/ /pubmed/28894642 http://dx.doi.org/10.7717/peerj.3763 Text en ©2017 Sigut et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited.
spellingShingle Ophthalmology
Sigut, Jose
Nunez, Omar
Fumero, Francisco
Gonzalez, Marta
Arnay, Rafael
Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images
title Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images
title_full Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images
title_fullStr Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images
title_full_unstemmed Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images
title_short Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images
title_sort contrast based circular approximation for accurate and robust optic disc segmentation in retinal images
topic Ophthalmology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5592085/
https://www.ncbi.nlm.nih.gov/pubmed/28894642
http://dx.doi.org/10.7717/peerj.3763
work_keys_str_mv AT sigutjose contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages
AT nunezomar contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages
AT fumerofrancisco contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages
AT gonzalezmarta contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages
AT arnayrafael contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages