Cargando…
Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images
A new method for automatic optic disc localization and segmentation is presented. The localization procedure combines vascular and brightness information to provide the best estimate of the optic disc center which is the starting point for the segmentation algorithm. A detection rate of 99.58% and 1...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PeerJ Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5592085/ https://www.ncbi.nlm.nih.gov/pubmed/28894642 http://dx.doi.org/10.7717/peerj.3763 |
_version_ | 1783262835225133056 |
---|---|
author | Sigut, Jose Nunez, Omar Fumero, Francisco Gonzalez, Marta Arnay, Rafael |
author_facet | Sigut, Jose Nunez, Omar Fumero, Francisco Gonzalez, Marta Arnay, Rafael |
author_sort | Sigut, Jose |
collection | PubMed |
description | A new method for automatic optic disc localization and segmentation is presented. The localization procedure combines vascular and brightness information to provide the best estimate of the optic disc center which is the starting point for the segmentation algorithm. A detection rate of 99.58% and 100% was achieved for the Messidor and ONHSD databases, respectively. A simple circular approximation to the optic disc boundary is proposed based on the maximum average contrast between the inner and outer ring of a circle centered on the estimated location. An average overlap coefficient of 0.890 and 0.865 was achieved for the same datasets, outperforming other state of the art methods. The results obtained confirm the advantages of using a simple circular model under non-ideal conditions as opposed to more complex deformable models. |
format | Online Article Text |
id | pubmed-5592085 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | PeerJ Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-55920852017-09-11 Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images Sigut, Jose Nunez, Omar Fumero, Francisco Gonzalez, Marta Arnay, Rafael PeerJ Ophthalmology A new method for automatic optic disc localization and segmentation is presented. The localization procedure combines vascular and brightness information to provide the best estimate of the optic disc center which is the starting point for the segmentation algorithm. A detection rate of 99.58% and 100% was achieved for the Messidor and ONHSD databases, respectively. A simple circular approximation to the optic disc boundary is proposed based on the maximum average contrast between the inner and outer ring of a circle centered on the estimated location. An average overlap coefficient of 0.890 and 0.865 was achieved for the same datasets, outperforming other state of the art methods. The results obtained confirm the advantages of using a simple circular model under non-ideal conditions as opposed to more complex deformable models. PeerJ Inc. 2017-09-07 /pmc/articles/PMC5592085/ /pubmed/28894642 http://dx.doi.org/10.7717/peerj.3763 Text en ©2017 Sigut et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. |
spellingShingle | Ophthalmology Sigut, Jose Nunez, Omar Fumero, Francisco Gonzalez, Marta Arnay, Rafael Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images |
title | Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images |
title_full | Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images |
title_fullStr | Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images |
title_full_unstemmed | Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images |
title_short | Contrast based circular approximation for accurate and robust optic disc segmentation in retinal images |
title_sort | contrast based circular approximation for accurate and robust optic disc segmentation in retinal images |
topic | Ophthalmology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5592085/ https://www.ncbi.nlm.nih.gov/pubmed/28894642 http://dx.doi.org/10.7717/peerj.3763 |
work_keys_str_mv | AT sigutjose contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages AT nunezomar contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages AT fumerofrancisco contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages AT gonzalezmarta contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages AT arnayrafael contrastbasedcircularapproximationforaccurateandrobustopticdiscsegmentationinretinalimages |