Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia

BACKGROUND: The relatively simple and cheaper light-emitting diode fluorescent microscopy (LED-FM) was recommended by the World Health Organization (WHO) to replace the conventional tuberculosis (TB) microscopy in both high- and low-volume laboratories. More recently the WHO also endorsed one more t...

Descripción completa

Detalles Bibliográficos
Autores principales: Gelalcha, Alemu Gadissa, Kebede, Abebaw, Mamo, Hassen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5594437/
https://www.ncbi.nlm.nih.gov/pubmed/28893193
http://dx.doi.org/10.1186/s12879-017-2701-5
_version_ 1783263200427376640
author Gelalcha, Alemu Gadissa
Kebede, Abebaw
Mamo, Hassen
author_facet Gelalcha, Alemu Gadissa
Kebede, Abebaw
Mamo, Hassen
author_sort Gelalcha, Alemu Gadissa
collection PubMed
description BACKGROUND: The relatively simple and cheaper light-emitting diode fluorescent microscopy (LED-FM) was recommended by the World Health Organization (WHO) to replace the conventional tuberculosis (TB) microscopy in both high- and low-volume laboratories. More recently the WHO also endorsed one more technique, Xpert MTB/RIF® assay (Xpert), for improved TB diagnosis particularly among human immunodeficiency virus (HIV)-infected cases. However, the relative performance of both of these tools differs from setting to setting in reference to the conventional TB diagnostics. This study thus aimed to evaluate these tools for TB detection in individuals visiting Ambo Hospital, west-central Ethiopia. METHODS: Cross-sectional early-morning sputum samples were collected from presumptive TB patients between January and August 2015. Socio-demographic data were captured using a structured questionnaire. Clinical information was gathered from patients’ medical records. The sputum samples were diagnosed using LED-FM, Xpert, concentrated Ziehl-Neelsen (cZN) staining and Lowenstein-Jensen (LJ) culture as the gold standard. Drug sensitivity test (DST) was also conducted. RESULTS: Out of 362 sputum samples collected and processed, 36(9.9%) were positive by LED-FM, 42(11.6%) by cZN and 50(13.8%) by Xpert. But, only 340 samples could be declared culture positive or negative for mycobacteria. Of these 340, eight were non-tubercle mycobacteria (NTM). Out of the remaining 332 samples, 45(13.6%) had culture-confirmed TB with 11(24.4%) being HIV co-infected. LED-FM, Xpert and culture detected 54.5% (6/11), 90.9% (10/11) and 100% (11/11) mycobacteria in HIV-positive individuals and 81.3% (26/32), 73.7% (28/38), 78.8% (26/33) and 73.2% (30/41), in HIV negatives respectively. Two samples were rifampicin resistant by both Xpert and DST. The overall sensitivity, specificity, positive and negative predictive values of LED-FM and Xpert were 77.8, 100, 100 and 96; and 93.3, 98, 97.5 and 98.9% respectively. CONCLUSION: The data demonstrated the high diagnostic yield of Xpert. LED-FM sensitivity is higher compared to results quoted by recent systematic reviews although it appears to be lower than what was cited in the WHO policy statement (83.6%) during the recommendation of the technology. The high specificity of LED-FM in the study area is encouraging and is expected to boost its reliability and uptake.
format Online
Article
Text
id pubmed-5594437
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-55944372017-09-14 Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia Gelalcha, Alemu Gadissa Kebede, Abebaw Mamo, Hassen BMC Infect Dis Research Article BACKGROUND: The relatively simple and cheaper light-emitting diode fluorescent microscopy (LED-FM) was recommended by the World Health Organization (WHO) to replace the conventional tuberculosis (TB) microscopy in both high- and low-volume laboratories. More recently the WHO also endorsed one more technique, Xpert MTB/RIF® assay (Xpert), for improved TB diagnosis particularly among human immunodeficiency virus (HIV)-infected cases. However, the relative performance of both of these tools differs from setting to setting in reference to the conventional TB diagnostics. This study thus aimed to evaluate these tools for TB detection in individuals visiting Ambo Hospital, west-central Ethiopia. METHODS: Cross-sectional early-morning sputum samples were collected from presumptive TB patients between January and August 2015. Socio-demographic data were captured using a structured questionnaire. Clinical information was gathered from patients’ medical records. The sputum samples were diagnosed using LED-FM, Xpert, concentrated Ziehl-Neelsen (cZN) staining and Lowenstein-Jensen (LJ) culture as the gold standard. Drug sensitivity test (DST) was also conducted. RESULTS: Out of 362 sputum samples collected and processed, 36(9.9%) were positive by LED-FM, 42(11.6%) by cZN and 50(13.8%) by Xpert. But, only 340 samples could be declared culture positive or negative for mycobacteria. Of these 340, eight were non-tubercle mycobacteria (NTM). Out of the remaining 332 samples, 45(13.6%) had culture-confirmed TB with 11(24.4%) being HIV co-infected. LED-FM, Xpert and culture detected 54.5% (6/11), 90.9% (10/11) and 100% (11/11) mycobacteria in HIV-positive individuals and 81.3% (26/32), 73.7% (28/38), 78.8% (26/33) and 73.2% (30/41), in HIV negatives respectively. Two samples were rifampicin resistant by both Xpert and DST. The overall sensitivity, specificity, positive and negative predictive values of LED-FM and Xpert were 77.8, 100, 100 and 96; and 93.3, 98, 97.5 and 98.9% respectively. CONCLUSION: The data demonstrated the high diagnostic yield of Xpert. LED-FM sensitivity is higher compared to results quoted by recent systematic reviews although it appears to be lower than what was cited in the WHO policy statement (83.6%) during the recommendation of the technology. The high specificity of LED-FM in the study area is encouraging and is expected to boost its reliability and uptake. BioMed Central 2017-09-11 /pmc/articles/PMC5594437/ /pubmed/28893193 http://dx.doi.org/10.1186/s12879-017-2701-5 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Gelalcha, Alemu Gadissa
Kebede, Abebaw
Mamo, Hassen
Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia
title Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia
title_full Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia
title_fullStr Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia
title_full_unstemmed Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia
title_short Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia
title_sort light-emitting diode fluorescent microscopy and xpert mtb/rif® assay for diagnosis of pulmonary tuberculosis among patients attending ambo hospital, west-central ethiopia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5594437/
https://www.ncbi.nlm.nih.gov/pubmed/28893193
http://dx.doi.org/10.1186/s12879-017-2701-5
work_keys_str_mv AT gelalchaalemugadissa lightemittingdiodefluorescentmicroscopyandxpertmtbrifassayfordiagnosisofpulmonarytuberculosisamongpatientsattendingambohospitalwestcentralethiopia
AT kebedeabebaw lightemittingdiodefluorescentmicroscopyandxpertmtbrifassayfordiagnosisofpulmonarytuberculosisamongpatientsattendingambohospitalwestcentralethiopia
AT mamohassen lightemittingdiodefluorescentmicroscopyandxpertmtbrifassayfordiagnosisofpulmonarytuberculosisamongpatientsattendingambohospitalwestcentralethiopia