Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses

BACKGROUND: Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed...

Descripción completa

Detalles Bibliográficos
Autores principales: Jousi, Milla, Saikko, Simo, Nurmi, Jouni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5594606/
https://www.ncbi.nlm.nih.gov/pubmed/28893316
http://dx.doi.org/10.1186/s13049-017-0435-4
_version_ 1783263237179965440
author Jousi, Milla
Saikko, Simo
Nurmi, Jouni
author_facet Jousi, Milla
Saikko, Simo
Nurmi, Jouni
author_sort Jousi, Milla
collection PubMed
description BACKGROUND: Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed for POC analyses in emergency situations. The aim of this study was to determine whether IO values agree sufficiently with arterial values to be used for clinical decision making. METHODS: Two samples of IO blood were drawn from 31 healthy volunteers and compared with arterial samples. The samples were analysed for sodium, potassium, ionized calcium, glucose, haemoglobin, haematocrit, pH, blood gases, base excess, bicarbonate, and lactate using the i-STAT® POC device. Agreement and reliability were estimated by using the Bland-Altman method and intraclass correlation coefficient calculations. RESULTS: Good agreement was evident between the IO and arterial samples for pH, glucose, and lactate. Potassium levels were clearly higher in the IO samples than those from arterial blood. Base excess and bicarbonate were slightly higher, and sodium and ionised calcium values were slightly lower, in the IO samples compared with the arterial values. The blood gases in the IO samples were between arterial and venous values. Haemoglobin and haematocrit showed remarkable variation in agreement. DISCUSSION: POC diagnostics of IO blood can be a useful tool to guide treatment in critical emergency care. Seeking out the reversible causes of cardiac arrest or assessing the severity of shock are examples of situations in which obtaining vascular access and blood samples can be difficult, though information about the electrolytes, acid-base balance, and lactate could guide clinical decision making. The analysis of IO samples should though be limited to situations in which no other option is available, and the results should be interpreted with caution, because there is not yet enough scientific evidence regarding the agreement of IO and arterial results among unstable patients. CONCLUSIONS: IO blood samples are suitable for analysis with the i-STAT® point-of-care device in emergency care. The aspirate used to confirm the correct placement of the IO needle can also be used for analysis. The results must be interpreted within a clinical context while taking the magnitude and direction of bias into account.
format Online
Article
Text
id pubmed-5594606
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-55946062017-09-15 Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses Jousi, Milla Saikko, Simo Nurmi, Jouni Scand J Trauma Resusc Emerg Med Original Research BACKGROUND: Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed for POC analyses in emergency situations. The aim of this study was to determine whether IO values agree sufficiently with arterial values to be used for clinical decision making. METHODS: Two samples of IO blood were drawn from 31 healthy volunteers and compared with arterial samples. The samples were analysed for sodium, potassium, ionized calcium, glucose, haemoglobin, haematocrit, pH, blood gases, base excess, bicarbonate, and lactate using the i-STAT® POC device. Agreement and reliability were estimated by using the Bland-Altman method and intraclass correlation coefficient calculations. RESULTS: Good agreement was evident between the IO and arterial samples for pH, glucose, and lactate. Potassium levels were clearly higher in the IO samples than those from arterial blood. Base excess and bicarbonate were slightly higher, and sodium and ionised calcium values were slightly lower, in the IO samples compared with the arterial values. The blood gases in the IO samples were between arterial and venous values. Haemoglobin and haematocrit showed remarkable variation in agreement. DISCUSSION: POC diagnostics of IO blood can be a useful tool to guide treatment in critical emergency care. Seeking out the reversible causes of cardiac arrest or assessing the severity of shock are examples of situations in which obtaining vascular access and blood samples can be difficult, though information about the electrolytes, acid-base balance, and lactate could guide clinical decision making. The analysis of IO samples should though be limited to situations in which no other option is available, and the results should be interpreted with caution, because there is not yet enough scientific evidence regarding the agreement of IO and arterial results among unstable patients. CONCLUSIONS: IO blood samples are suitable for analysis with the i-STAT® point-of-care device in emergency care. The aspirate used to confirm the correct placement of the IO needle can also be used for analysis. The results must be interpreted within a clinical context while taking the magnitude and direction of bias into account. BioMed Central 2017-09-11 /pmc/articles/PMC5594606/ /pubmed/28893316 http://dx.doi.org/10.1186/s13049-017-0435-4 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Research
Jousi, Milla
Saikko, Simo
Nurmi, Jouni
Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses
title Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses
title_full Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses
title_fullStr Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses
title_full_unstemmed Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses
title_short Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses
title_sort intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5594606/
https://www.ncbi.nlm.nih.gov/pubmed/28893316
http://dx.doi.org/10.1186/s13049-017-0435-4
work_keys_str_mv AT jousimilla intraosseousbloodsamplesforpointofcareanalysisagreementbetweenintraosseousandarterialanalyses
AT saikkosimo intraosseousbloodsamplesforpointofcareanalysisagreementbetweenintraosseousandarterialanalyses
AT nurmijouni intraosseousbloodsamplesforpointofcareanalysisagreementbetweenintraosseousandarterialanalyses