Cargando…

REPRODUCIBILITY OF SCHATZKER CLASSIFICATION THROUGH SMARTPHONE APPLICATIONS

OBJECTIVE: To evaluate the intra-observer reproducibility of Schatzker classification for tibial plateau fractures through smartphone applications. METHODS: Radiographs were evaluated in two incidences (anteroposterior and profile) and CT slices (axial, sagittal and coronal) of 37 patients with tibi...

Descripción completa

Detalles Bibliográficos
Autores principales: dos Santos, Mauro Rodrigues, Sado, Junichiro, de Sousa, Roberto Medeiros, Roriz, Osman Rodrigues
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Departamento de Ortopedia e Traumatologia (DOT/FMUSP) 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5594756/
https://www.ncbi.nlm.nih.gov/pubmed/28924356
http://dx.doi.org/10.1590/1413-785220162406159078
_version_ 1783263251587399680
author dos Santos, Mauro Rodrigues
Sado, Junichiro
de Sousa, Roberto Medeiros
Roriz, Osman Rodrigues
author_facet dos Santos, Mauro Rodrigues
Sado, Junichiro
de Sousa, Roberto Medeiros
Roriz, Osman Rodrigues
author_sort dos Santos, Mauro Rodrigues
collection PubMed
description OBJECTIVE: To evaluate the intra-observer reproducibility of Schatzker classification for tibial plateau fractures through smartphone applications. METHODS: Radiographs were evaluated in two incidences (anteroposterior and profile) and CT slices (axial, sagittal and coronal) of 37 patients with tibial plateau fracture. Two evaluators, knee surgery experts, classified the cases by viewing the images of the isolated radiographs and then X-rays associated with CT slices in four different stages via smartphones and then presential assessment. Data were statistically analyzed with the Kappa coefficient (k). RESULTS: There was intra-observer agreement by comparing the two methods of evaluation: display or via smartphone, and the analysis made showed statistical significance. CONCLUSION: The use of smartphones did not affect the reliability of Schatzker classification. Level of Evidence III, Diagnostic Study - Investigating a Diagnostic Test.
format Online
Article
Text
id pubmed-5594756
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Departamento de Ortopedia e Traumatologia (DOT/FMUSP)
record_format MEDLINE/PubMed
spelling pubmed-55947562017-09-18 REPRODUCIBILITY OF SCHATZKER CLASSIFICATION THROUGH SMARTPHONE APPLICATIONS dos Santos, Mauro Rodrigues Sado, Junichiro de Sousa, Roberto Medeiros Roriz, Osman Rodrigues Acta Ortop Bras Original Article OBJECTIVE: To evaluate the intra-observer reproducibility of Schatzker classification for tibial plateau fractures through smartphone applications. METHODS: Radiographs were evaluated in two incidences (anteroposterior and profile) and CT slices (axial, sagittal and coronal) of 37 patients with tibial plateau fracture. Two evaluators, knee surgery experts, classified the cases by viewing the images of the isolated radiographs and then X-rays associated with CT slices in four different stages via smartphones and then presential assessment. Data were statistically analyzed with the Kappa coefficient (k). RESULTS: There was intra-observer agreement by comparing the two methods of evaluation: display or via smartphone, and the analysis made showed statistical significance. CONCLUSION: The use of smartphones did not affect the reliability of Schatzker classification. Level of Evidence III, Diagnostic Study - Investigating a Diagnostic Test. Departamento de Ortopedia e Traumatologia (DOT/FMUSP) 2016 /pmc/articles/PMC5594756/ /pubmed/28924356 http://dx.doi.org/10.1590/1413-785220162406159078 Text en http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Original Article
dos Santos, Mauro Rodrigues
Sado, Junichiro
de Sousa, Roberto Medeiros
Roriz, Osman Rodrigues
REPRODUCIBILITY OF SCHATZKER CLASSIFICATION THROUGH SMARTPHONE APPLICATIONS
title REPRODUCIBILITY OF SCHATZKER CLASSIFICATION THROUGH SMARTPHONE APPLICATIONS
title_full REPRODUCIBILITY OF SCHATZKER CLASSIFICATION THROUGH SMARTPHONE APPLICATIONS
title_fullStr REPRODUCIBILITY OF SCHATZKER CLASSIFICATION THROUGH SMARTPHONE APPLICATIONS
title_full_unstemmed REPRODUCIBILITY OF SCHATZKER CLASSIFICATION THROUGH SMARTPHONE APPLICATIONS
title_short REPRODUCIBILITY OF SCHATZKER CLASSIFICATION THROUGH SMARTPHONE APPLICATIONS
title_sort reproducibility of schatzker classification through smartphone applications
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5594756/
https://www.ncbi.nlm.nih.gov/pubmed/28924356
http://dx.doi.org/10.1590/1413-785220162406159078
work_keys_str_mv AT dossantosmaurorodrigues reproducibilityofschatzkerclassificationthroughsmartphoneapplications
AT sadojunichiro reproducibilityofschatzkerclassificationthroughsmartphoneapplications
AT desousarobertomedeiros reproducibilityofschatzkerclassificationthroughsmartphoneapplications
AT rorizosmanrodrigues reproducibilityofschatzkerclassificationthroughsmartphoneapplications