Cargando…
Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography
OBJECTIVES: The correlation of optic nerve sheath diameter (ONSD) as seen on ultrasonography (US) and directly measured intracranial pressure (ICP) has been well described. Nevertheless, differences in ethnicity and type of ICP monitor used are obstacles to the interpretation. Therefore, we investig...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5597178/ https://www.ncbi.nlm.nih.gov/pubmed/28902893 http://dx.doi.org/10.1371/journal.pone.0183170 |
_version_ | 1783263663766896640 |
---|---|
author | Jeon, Jin Pyeong Lee, Si Un Kim, Sung-Eun Kang, Suk Hyung Yang, Jin Seo Choi, Hyuk Jai Cho, Yong Jun Ban, Seung Pil Byoun, Hyoung Soo Kim, Young Soo |
author_facet | Jeon, Jin Pyeong Lee, Si Un Kim, Sung-Eun Kang, Suk Hyung Yang, Jin Seo Choi, Hyuk Jai Cho, Yong Jun Ban, Seung Pil Byoun, Hyoung Soo Kim, Young Soo |
author_sort | Jeon, Jin Pyeong |
collection | PubMed |
description | OBJECTIVES: The correlation of optic nerve sheath diameter (ONSD) as seen on ultrasonography (US) and directly measured intracranial pressure (ICP) has been well described. Nevertheless, differences in ethnicity and type of ICP monitor used are obstacles to the interpretation. Therefore, we investigated the direct correlation between ONSD and ventricular ICP and defined an optimal cut-off point for identifying increased ICP (IICP) in Korean adults with brain lesions. METHODS: This prospective study included patients who required an external ventricular drainage (EVD) catheter for ICP control. IICP was defined as an opening pressure over 20 mmHg. ONSD was measured using a 13 MHz US probe before the procedure. Linear regression analysis and receiver operator characteristic (ROC) curve were used to assess the association between ONSD and ICP. Optimal cut-off value for identifying IICP was defined. RESULTS: A total of 62 patients who underwent ONSD measurement with simultaneous EVD catheter placement were enrolled in this study. Thirty-two patients (51.6%) were found to have IICP. ONSD in patients with IICP (5.80 ± 0.45 mm) was significantly higher than in those without IICP (5.30 ± 0.61 mm) (P < 0.01). The IICP group showed more significant linear correlation with ONSD (r = 0.57, P < 0.01) compared to the non-IICP group (r = 0.42, P = 0.02). ONSD > 5.6 mm disclosed a sensitivity of 93.75% and a specificity of 86.67% for identifying IICP. CONCLUSION: ONSD as seen on bedside US correlated well with directly measured ICP in Korean adults with brain lesions. The optimal cut-off point of ONSD for detecting IICP was 5.6 mm. |
format | Online Article Text |
id | pubmed-5597178 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-55971782017-09-15 Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography Jeon, Jin Pyeong Lee, Si Un Kim, Sung-Eun Kang, Suk Hyung Yang, Jin Seo Choi, Hyuk Jai Cho, Yong Jun Ban, Seung Pil Byoun, Hyoung Soo Kim, Young Soo PLoS One Research Article OBJECTIVES: The correlation of optic nerve sheath diameter (ONSD) as seen on ultrasonography (US) and directly measured intracranial pressure (ICP) has been well described. Nevertheless, differences in ethnicity and type of ICP monitor used are obstacles to the interpretation. Therefore, we investigated the direct correlation between ONSD and ventricular ICP and defined an optimal cut-off point for identifying increased ICP (IICP) in Korean adults with brain lesions. METHODS: This prospective study included patients who required an external ventricular drainage (EVD) catheter for ICP control. IICP was defined as an opening pressure over 20 mmHg. ONSD was measured using a 13 MHz US probe before the procedure. Linear regression analysis and receiver operator characteristic (ROC) curve were used to assess the association between ONSD and ICP. Optimal cut-off value for identifying IICP was defined. RESULTS: A total of 62 patients who underwent ONSD measurement with simultaneous EVD catheter placement were enrolled in this study. Thirty-two patients (51.6%) were found to have IICP. ONSD in patients with IICP (5.80 ± 0.45 mm) was significantly higher than in those without IICP (5.30 ± 0.61 mm) (P < 0.01). The IICP group showed more significant linear correlation with ONSD (r = 0.57, P < 0.01) compared to the non-IICP group (r = 0.42, P = 0.02). ONSD > 5.6 mm disclosed a sensitivity of 93.75% and a specificity of 86.67% for identifying IICP. CONCLUSION: ONSD as seen on bedside US correlated well with directly measured ICP in Korean adults with brain lesions. The optimal cut-off point of ONSD for detecting IICP was 5.6 mm. Public Library of Science 2017-09-13 /pmc/articles/PMC5597178/ /pubmed/28902893 http://dx.doi.org/10.1371/journal.pone.0183170 Text en © 2017 Jeon et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Jeon, Jin Pyeong Lee, Si Un Kim, Sung-Eun Kang, Suk Hyung Yang, Jin Seo Choi, Hyuk Jai Cho, Yong Jun Ban, Seung Pil Byoun, Hyoung Soo Kim, Young Soo Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography |
title | Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography |
title_full | Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography |
title_fullStr | Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography |
title_full_unstemmed | Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography |
title_short | Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography |
title_sort | correlation of optic nerve sheath diameter with directly measured intracranial pressure in korean adults using bedside ultrasonography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5597178/ https://www.ncbi.nlm.nih.gov/pubmed/28902893 http://dx.doi.org/10.1371/journal.pone.0183170 |
work_keys_str_mv | AT jeonjinpyeong correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography AT leesiun correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography AT kimsungeun correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography AT kangsukhyung correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography AT yangjinseo correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography AT choihyukjai correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography AT choyongjun correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography AT banseungpil correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography AT byounhyoungsoo correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography AT kimyoungsoo correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography |