Cargando…

Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography

OBJECTIVES: The correlation of optic nerve sheath diameter (ONSD) as seen on ultrasonography (US) and directly measured intracranial pressure (ICP) has been well described. Nevertheless, differences in ethnicity and type of ICP monitor used are obstacles to the interpretation. Therefore, we investig...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeon, Jin Pyeong, Lee, Si Un, Kim, Sung-Eun, Kang, Suk Hyung, Yang, Jin Seo, Choi, Hyuk Jai, Cho, Yong Jun, Ban, Seung Pil, Byoun, Hyoung Soo, Kim, Young Soo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5597178/
https://www.ncbi.nlm.nih.gov/pubmed/28902893
http://dx.doi.org/10.1371/journal.pone.0183170
_version_ 1783263663766896640
author Jeon, Jin Pyeong
Lee, Si Un
Kim, Sung-Eun
Kang, Suk Hyung
Yang, Jin Seo
Choi, Hyuk Jai
Cho, Yong Jun
Ban, Seung Pil
Byoun, Hyoung Soo
Kim, Young Soo
author_facet Jeon, Jin Pyeong
Lee, Si Un
Kim, Sung-Eun
Kang, Suk Hyung
Yang, Jin Seo
Choi, Hyuk Jai
Cho, Yong Jun
Ban, Seung Pil
Byoun, Hyoung Soo
Kim, Young Soo
author_sort Jeon, Jin Pyeong
collection PubMed
description OBJECTIVES: The correlation of optic nerve sheath diameter (ONSD) as seen on ultrasonography (US) and directly measured intracranial pressure (ICP) has been well described. Nevertheless, differences in ethnicity and type of ICP monitor used are obstacles to the interpretation. Therefore, we investigated the direct correlation between ONSD and ventricular ICP and defined an optimal cut-off point for identifying increased ICP (IICP) in Korean adults with brain lesions. METHODS: This prospective study included patients who required an external ventricular drainage (EVD) catheter for ICP control. IICP was defined as an opening pressure over 20 mmHg. ONSD was measured using a 13 MHz US probe before the procedure. Linear regression analysis and receiver operator characteristic (ROC) curve were used to assess the association between ONSD and ICP. Optimal cut-off value for identifying IICP was defined. RESULTS: A total of 62 patients who underwent ONSD measurement with simultaneous EVD catheter placement were enrolled in this study. Thirty-two patients (51.6%) were found to have IICP. ONSD in patients with IICP (5.80 ± 0.45 mm) was significantly higher than in those without IICP (5.30 ± 0.61 mm) (P < 0.01). The IICP group showed more significant linear correlation with ONSD (r = 0.57, P < 0.01) compared to the non-IICP group (r = 0.42, P = 0.02). ONSD > 5.6 mm disclosed a sensitivity of 93.75% and a specificity of 86.67% for identifying IICP. CONCLUSION: ONSD as seen on bedside US correlated well with directly measured ICP in Korean adults with brain lesions. The optimal cut-off point of ONSD for detecting IICP was 5.6 mm.
format Online
Article
Text
id pubmed-5597178
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-55971782017-09-15 Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography Jeon, Jin Pyeong Lee, Si Un Kim, Sung-Eun Kang, Suk Hyung Yang, Jin Seo Choi, Hyuk Jai Cho, Yong Jun Ban, Seung Pil Byoun, Hyoung Soo Kim, Young Soo PLoS One Research Article OBJECTIVES: The correlation of optic nerve sheath diameter (ONSD) as seen on ultrasonography (US) and directly measured intracranial pressure (ICP) has been well described. Nevertheless, differences in ethnicity and type of ICP monitor used are obstacles to the interpretation. Therefore, we investigated the direct correlation between ONSD and ventricular ICP and defined an optimal cut-off point for identifying increased ICP (IICP) in Korean adults with brain lesions. METHODS: This prospective study included patients who required an external ventricular drainage (EVD) catheter for ICP control. IICP was defined as an opening pressure over 20 mmHg. ONSD was measured using a 13 MHz US probe before the procedure. Linear regression analysis and receiver operator characteristic (ROC) curve were used to assess the association between ONSD and ICP. Optimal cut-off value for identifying IICP was defined. RESULTS: A total of 62 patients who underwent ONSD measurement with simultaneous EVD catheter placement were enrolled in this study. Thirty-two patients (51.6%) were found to have IICP. ONSD in patients with IICP (5.80 ± 0.45 mm) was significantly higher than in those without IICP (5.30 ± 0.61 mm) (P < 0.01). The IICP group showed more significant linear correlation with ONSD (r = 0.57, P < 0.01) compared to the non-IICP group (r = 0.42, P = 0.02). ONSD > 5.6 mm disclosed a sensitivity of 93.75% and a specificity of 86.67% for identifying IICP. CONCLUSION: ONSD as seen on bedside US correlated well with directly measured ICP in Korean adults with brain lesions. The optimal cut-off point of ONSD for detecting IICP was 5.6 mm. Public Library of Science 2017-09-13 /pmc/articles/PMC5597178/ /pubmed/28902893 http://dx.doi.org/10.1371/journal.pone.0183170 Text en © 2017 Jeon et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Jeon, Jin Pyeong
Lee, Si Un
Kim, Sung-Eun
Kang, Suk Hyung
Yang, Jin Seo
Choi, Hyuk Jai
Cho, Yong Jun
Ban, Seung Pil
Byoun, Hyoung Soo
Kim, Young Soo
Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography
title Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography
title_full Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography
title_fullStr Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography
title_full_unstemmed Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography
title_short Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography
title_sort correlation of optic nerve sheath diameter with directly measured intracranial pressure in korean adults using bedside ultrasonography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5597178/
https://www.ncbi.nlm.nih.gov/pubmed/28902893
http://dx.doi.org/10.1371/journal.pone.0183170
work_keys_str_mv AT jeonjinpyeong correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography
AT leesiun correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography
AT kimsungeun correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography
AT kangsukhyung correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography
AT yangjinseo correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography
AT choihyukjai correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography
AT choyongjun correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography
AT banseungpil correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography
AT byounhyoungsoo correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography
AT kimyoungsoo correlationofopticnervesheathdiameterwithdirectlymeasuredintracranialpressureinkoreanadultsusingbedsideultrasonography