Cargando…

Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL

OBJECTIVE: Assess the need for folate testing, frequency of corrective action, and determine reference level for serum folate. METHODS: Serum folate levels in 5313 samples from 4448 patients, and clinical data were reviewed for patient characteristics and for (a) evidence of corrective action in pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Gurmukh, Hamdan, Hana, Singh, Vivek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5597708/
https://www.ncbi.nlm.nih.gov/pubmed/28932797
http://dx.doi.org/10.1016/j.plabm.2015.03.005
_version_ 1783263758523564032
author Singh, Gurmukh
Hamdan, Hana
Singh, Vivek
author_facet Singh, Gurmukh
Hamdan, Hana
Singh, Vivek
author_sort Singh, Gurmukh
collection PubMed
description OBJECTIVE: Assess the need for folate testing, frequency of corrective action, and determine reference level for serum folate. METHODS: Serum folate levels in 5313 samples from 4448 patients, and clinical data were reviewed for patient characteristics and for (a) evidence of corrective action in patients with serum folate values <5.5 ng/mL, and (b) differences in patients with serum folate levels <5.5 ng/mL and patients with levels >25.7 ng/mL. RESULTS: The prevalence of serum folate levels, in patients, <3.0, <4.0, <5.5, <7.0 and <13.0 ng/mL was 0.58%, 1.55%, 4.9%, 9.98% and 43.21% respectively. Patients with serum folate levels <5.5 ng/mL had lower serum albumin and hemoglobin. In 64% of patients with serum folate >25.7 ng/mL the sample was collected after supplementation with folic acid. Of the 128 patients with serum folate <5.5 ng/mL documentation of supplementation was present in only 38.9%. CONCLUSIONS: Serum folate levels are below the current “normal” level of 3.0 ng/mL in a larger proportion of tertiary care patients than that reported for ambulatory patients. In patients with folate deficiency, corrective action is lacking in >60% of the patients. Since serum folate levels ≥13.0 ng/mL are needed for optimal prevention of neural tube defects in the embryo/fetus, we propose that normal serum folate level should be designated to be ≥13.0 ng/mL.
format Online
Article
Text
id pubmed-5597708
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-55977082017-09-20 Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL Singh, Gurmukh Hamdan, Hana Singh, Vivek Pract Lab Med Research Article OBJECTIVE: Assess the need for folate testing, frequency of corrective action, and determine reference level for serum folate. METHODS: Serum folate levels in 5313 samples from 4448 patients, and clinical data were reviewed for patient characteristics and for (a) evidence of corrective action in patients with serum folate values <5.5 ng/mL, and (b) differences in patients with serum folate levels <5.5 ng/mL and patients with levels >25.7 ng/mL. RESULTS: The prevalence of serum folate levels, in patients, <3.0, <4.0, <5.5, <7.0 and <13.0 ng/mL was 0.58%, 1.55%, 4.9%, 9.98% and 43.21% respectively. Patients with serum folate levels <5.5 ng/mL had lower serum albumin and hemoglobin. In 64% of patients with serum folate >25.7 ng/mL the sample was collected after supplementation with folic acid. Of the 128 patients with serum folate <5.5 ng/mL documentation of supplementation was present in only 38.9%. CONCLUSIONS: Serum folate levels are below the current “normal” level of 3.0 ng/mL in a larger proportion of tertiary care patients than that reported for ambulatory patients. In patients with folate deficiency, corrective action is lacking in >60% of the patients. Since serum folate levels ≥13.0 ng/mL are needed for optimal prevention of neural tube defects in the embryo/fetus, we propose that normal serum folate level should be designated to be ≥13.0 ng/mL. Elsevier 2015-03-26 /pmc/articles/PMC5597708/ /pubmed/28932797 http://dx.doi.org/10.1016/j.plabm.2015.03.005 Text en © 2015 Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Singh, Gurmukh
Hamdan, Hana
Singh, Vivek
Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL
title Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL
title_full Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL
title_fullStr Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL
title_full_unstemmed Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL
title_short Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL
title_sort clinical utility of serum folate measurement in tertiary care patients: argument for revising reference range for serum folate from 3.0 ng/ml to 13.0 ng/ml
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5597708/
https://www.ncbi.nlm.nih.gov/pubmed/28932797
http://dx.doi.org/10.1016/j.plabm.2015.03.005
work_keys_str_mv AT singhgurmukh clinicalutilityofserumfolatemeasurementintertiarycarepatientsargumentforrevisingreferencerangeforserumfolatefrom30ngmlto130ngml
AT hamdanhana clinicalutilityofserumfolatemeasurementintertiarycarepatientsargumentforrevisingreferencerangeforserumfolatefrom30ngmlto130ngml
AT singhvivek clinicalutilityofserumfolatemeasurementintertiarycarepatientsargumentforrevisingreferencerangeforserumfolatefrom30ngmlto130ngml