Cargando…
Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL
OBJECTIVE: To define the performance characteristics of the LOCI(®) method for cardiac troponin I on the Dimension EXL system. DESIGNS AND METHODS: Three different levels of commercial control (mean concentrations 0.426, 1.42, and 18.64 µg/L) were used for the imprecision study, quantifying separate...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5597712/ https://www.ncbi.nlm.nih.gov/pubmed/28932798 http://dx.doi.org/10.1016/j.plabm.2015.03.006 |
_version_ | 1783263759517614080 |
---|---|
author | Calderón, José L. Martín Pérez, Julia M. Varona Bustos, Fernando Gómez, Juan C. Sánchez |
author_facet | Calderón, José L. Martín Pérez, Julia M. Varona Bustos, Fernando Gómez, Juan C. Sánchez |
author_sort | Calderón, José L. Martín |
collection | PubMed |
description | OBJECTIVE: To define the performance characteristics of the LOCI(®) method for cardiac troponin I on the Dimension EXL system. DESIGNS AND METHODS: Three different levels of commercial control (mean concentrations 0.426, 1.42, and 18.64 µg/L) were used for the imprecision study, quantifying separately within-run and between-run over 20 days. The limit of blank (LoB) and limit of detection (LoD) were assessed with 20 replicates of a sample without troponin I. Linearity was assessed by regression analysis. In addition, we studied inaccuracy, carry-over and limit of quantitation and conducted a method comparison with the Stratus CS (n=69). The reference interval was determined in 146 healthy blood donors using non-parametric method. RESULTS: The within-run imprecision (coefficient of variation [CV], %) obtained at each level was 2.4, 1.4% and 2.2%, while the between-run imprecision (CV,%) was 3.3%, 2.9% and 2.5%. Total imprecision was 4.06%, 3.3% and 3.4% for each control level. The limit of quantitation which corresponds to the troponin I concentration at which CV=10% was 0.05 µg/L. Method comparison with the Stratus CS assay produced the equation: Dimension EXL=−0.002698+1.0233(⁎)(Stratus CS) with a confidence interval from −0.01562 to 0.00626 for the intercept and (0.979 to 1.0875) for the slope. The 99th percentile obtained for the reference population was 0.047 µg/L. CONCLUSIONS: The LOCI method for cardiac troponin I on the Dimension EXL meets all guidelines recommended criteria referring to limit of quantitation, imprecision and shows excellent transferability with the Stratus CS method. |
format | Online Article Text |
id | pubmed-5597712 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-55977122017-09-20 Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL Calderón, José L. Martín Pérez, Julia M. Varona Bustos, Fernando Gómez, Juan C. Sánchez Pract Lab Med Research Article OBJECTIVE: To define the performance characteristics of the LOCI(®) method for cardiac troponin I on the Dimension EXL system. DESIGNS AND METHODS: Three different levels of commercial control (mean concentrations 0.426, 1.42, and 18.64 µg/L) were used for the imprecision study, quantifying separately within-run and between-run over 20 days. The limit of blank (LoB) and limit of detection (LoD) were assessed with 20 replicates of a sample without troponin I. Linearity was assessed by regression analysis. In addition, we studied inaccuracy, carry-over and limit of quantitation and conducted a method comparison with the Stratus CS (n=69). The reference interval was determined in 146 healthy blood donors using non-parametric method. RESULTS: The within-run imprecision (coefficient of variation [CV], %) obtained at each level was 2.4, 1.4% and 2.2%, while the between-run imprecision (CV,%) was 3.3%, 2.9% and 2.5%. Total imprecision was 4.06%, 3.3% and 3.4% for each control level. The limit of quantitation which corresponds to the troponin I concentration at which CV=10% was 0.05 µg/L. Method comparison with the Stratus CS assay produced the equation: Dimension EXL=−0.002698+1.0233(⁎)(Stratus CS) with a confidence interval from −0.01562 to 0.00626 for the intercept and (0.979 to 1.0875) for the slope. The 99th percentile obtained for the reference population was 0.047 µg/L. CONCLUSIONS: The LOCI method for cardiac troponin I on the Dimension EXL meets all guidelines recommended criteria referring to limit of quantitation, imprecision and shows excellent transferability with the Stratus CS method. Elsevier 2015-04-08 /pmc/articles/PMC5597712/ /pubmed/28932798 http://dx.doi.org/10.1016/j.plabm.2015.03.006 Text en © 2015 Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Calderón, José L. Martín Pérez, Julia M. Varona Bustos, Fernando Gómez, Juan C. Sánchez Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL |
title | Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL |
title_full | Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL |
title_fullStr | Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL |
title_full_unstemmed | Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL |
title_short | Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL |
title_sort | performance characteristics of loci method for measuring cardiac troponin i on the dimension exl |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5597712/ https://www.ncbi.nlm.nih.gov/pubmed/28932798 http://dx.doi.org/10.1016/j.plabm.2015.03.006 |
work_keys_str_mv | AT calderonjoselmartin performancecharacteristicsoflocimethodformeasuringcardiactroponinionthedimensionexl AT perezjuliamvarona performancecharacteristicsoflocimethodformeasuringcardiactroponinionthedimensionexl AT bustosfernando performancecharacteristicsoflocimethodformeasuringcardiactroponinionthedimensionexl AT gomezjuancsanchez performancecharacteristicsoflocimethodformeasuringcardiactroponinionthedimensionexl |