Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia
The Near-infrared spectroscopy (NIRS) has not been adopted as a mainstream monitoring modality in acute neurosurgical care due to concerns about its reliability and consistency. However, improvements in NIRS parameter recovery techniques are now available that may improve the quantitative accuracy o...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5599440/ https://www.ncbi.nlm.nih.gov/pubmed/27778208 http://dx.doi.org/10.1007/s10877-016-9942-5 |
_version_ | 1783264056295030784 |
---|---|
author | Davies, David James Clancy, Michael Lighter, Daniel Balanos, George M. Lucas, Samuel John Edwin Dehghani, Hamid Su, Zhangjie Forcione, Mario Belli, Antonio |
author_facet | Davies, David James Clancy, Michael Lighter, Daniel Balanos, George M. Lucas, Samuel John Edwin Dehghani, Hamid Su, Zhangjie Forcione, Mario Belli, Antonio |
author_sort | Davies, David James |
collection | PubMed |
description | The Near-infrared spectroscopy (NIRS) has not been adopted as a mainstream monitoring modality in acute neurosurgical care due to concerns about its reliability and consistency. However, improvements in NIRS parameter recovery techniques are now available that may improve the quantitative accuracy of NIRS for this clinical context. Therefore, the aim of this study was to compare the abilities of a continuous-wave (CW) NIRS device with a similarly clinically viable NIRS device utilising a frequency-domain (FD) parameter recovery technique in detecting changes in cerebral tissue saturation during stepwise increases of experimentally induced hypoxia. Nine healthy individuals (6M/3F) underwent a dynamic end-tidal forced manipulation of their expiratory gases to induce a stepwise induced hypoxia. The minimum end-tidal oxygen partial pressure (EtO(2)) achieved was 40 mm Hg. Simultaneous neurological and extra-cranial tissue NIRS reading were obtained during this protocol by both tested devices. Both devices detected significant changes in cerebral tissue saturation during the induction of hypoxia (CW 9.8 ± 2.3 %; FD 7.0 ± 3.4 %; Wilcoxon signed rank test P < 0.01 for both devices). No significant difference was observed between the saturation changes observed by either device (P = 0.625). An observably greater degree of noise was noticed in parameters recovered by the FD device, and both demonstrated equally variable baseline readings (Coefficient of variance 8.4 and 9.7 % for the CW and FD devices, respectively) between individuals tested. No advantageous difference was observed in parameters recovered from the FD device compared with those detected by CW. |
format | Online Article Text |
id | pubmed-5599440 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-55994402017-10-03 Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia Davies, David James Clancy, Michael Lighter, Daniel Balanos, George M. Lucas, Samuel John Edwin Dehghani, Hamid Su, Zhangjie Forcione, Mario Belli, Antonio J Clin Monit Comput Original Research The Near-infrared spectroscopy (NIRS) has not been adopted as a mainstream monitoring modality in acute neurosurgical care due to concerns about its reliability and consistency. However, improvements in NIRS parameter recovery techniques are now available that may improve the quantitative accuracy of NIRS for this clinical context. Therefore, the aim of this study was to compare the abilities of a continuous-wave (CW) NIRS device with a similarly clinically viable NIRS device utilising a frequency-domain (FD) parameter recovery technique in detecting changes in cerebral tissue saturation during stepwise increases of experimentally induced hypoxia. Nine healthy individuals (6M/3F) underwent a dynamic end-tidal forced manipulation of their expiratory gases to induce a stepwise induced hypoxia. The minimum end-tidal oxygen partial pressure (EtO(2)) achieved was 40 mm Hg. Simultaneous neurological and extra-cranial tissue NIRS reading were obtained during this protocol by both tested devices. Both devices detected significant changes in cerebral tissue saturation during the induction of hypoxia (CW 9.8 ± 2.3 %; FD 7.0 ± 3.4 %; Wilcoxon signed rank test P < 0.01 for both devices). No significant difference was observed between the saturation changes observed by either device (P = 0.625). An observably greater degree of noise was noticed in parameters recovered by the FD device, and both demonstrated equally variable baseline readings (Coefficient of variance 8.4 and 9.7 % for the CW and FD devices, respectively) between individuals tested. No advantageous difference was observed in parameters recovered from the FD device compared with those detected by CW. Springer Netherlands 2016-10-24 2017 /pmc/articles/PMC5599440/ /pubmed/27778208 http://dx.doi.org/10.1007/s10877-016-9942-5 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research Davies, David James Clancy, Michael Lighter, Daniel Balanos, George M. Lucas, Samuel John Edwin Dehghani, Hamid Su, Zhangjie Forcione, Mario Belli, Antonio Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia |
title | Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia |
title_full | Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia |
title_fullStr | Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia |
title_full_unstemmed | Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia |
title_short | Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia |
title_sort | frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5599440/ https://www.ncbi.nlm.nih.gov/pubmed/27778208 http://dx.doi.org/10.1007/s10877-016-9942-5 |
work_keys_str_mv | AT daviesdavidjames frequencydomainvscontinuouswavenearinfraredspectroscopydevicesacomparisonofclinicallyviablemonitorsincontrolledhypoxia AT clancymichael frequencydomainvscontinuouswavenearinfraredspectroscopydevicesacomparisonofclinicallyviablemonitorsincontrolledhypoxia AT lighterdaniel frequencydomainvscontinuouswavenearinfraredspectroscopydevicesacomparisonofclinicallyviablemonitorsincontrolledhypoxia AT balanosgeorgem frequencydomainvscontinuouswavenearinfraredspectroscopydevicesacomparisonofclinicallyviablemonitorsincontrolledhypoxia AT lucassamueljohnedwin frequencydomainvscontinuouswavenearinfraredspectroscopydevicesacomparisonofclinicallyviablemonitorsincontrolledhypoxia AT dehghanihamid frequencydomainvscontinuouswavenearinfraredspectroscopydevicesacomparisonofclinicallyviablemonitorsincontrolledhypoxia AT suzhangjie frequencydomainvscontinuouswavenearinfraredspectroscopydevicesacomparisonofclinicallyviablemonitorsincontrolledhypoxia AT forcionemario frequencydomainvscontinuouswavenearinfraredspectroscopydevicesacomparisonofclinicallyviablemonitorsincontrolledhypoxia AT belliantonio frequencydomainvscontinuouswavenearinfraredspectroscopydevicesacomparisonofclinicallyviablemonitorsincontrolledhypoxia |