Cargando…

Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation

Cuffless technique enables continuous blood pressure (BP) measurement in an unobtrusive manner, and thus has the potential to revolutionize the conventional cuff-based approaches. This study extends the pulse transit time (PTT) based cuffless BP measurement method by introducing a new indicator – th...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Xiaorong, Yan, Bryan P., Zhang, Yuan-Ting, Liu, Jing, Zhao, Ni, Tsang, Hon Ki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5599606/
https://www.ncbi.nlm.nih.gov/pubmed/28912525
http://dx.doi.org/10.1038/s41598-017-11507-3
_version_ 1783264093070688256
author Ding, Xiaorong
Yan, Bryan P.
Zhang, Yuan-Ting
Liu, Jing
Zhao, Ni
Tsang, Hon Ki
author_facet Ding, Xiaorong
Yan, Bryan P.
Zhang, Yuan-Ting
Liu, Jing
Zhao, Ni
Tsang, Hon Ki
author_sort Ding, Xiaorong
collection PubMed
description Cuffless technique enables continuous blood pressure (BP) measurement in an unobtrusive manner, and thus has the potential to revolutionize the conventional cuff-based approaches. This study extends the pulse transit time (PTT) based cuffless BP measurement method by introducing a new indicator – the photoplethysmogram (PPG) intensity ratio (PIR). The performance of the models with PTT and PIR was comprehensively evaluated in comparison with six models that are based on sole PTT. The validation conducted on 33 subjects with and without hypertension, at rest and under various maneuvers with induced BP changes, and over an extended calibration interval, respectively. The results showed that, comparing to the PTT models, the proposed methods achieved better accuracy on each subject group at rest state and over 24 hours calibration interval. Although the BP estimation errors under dynamic maneuvers and over extended calibration interval were significantly increased for all methods, the proposed methods still outperformed the compared methods in the latter situation. These findings suggest that additional BP-related indicator other than PTT has added value for improving the accuracy of cuffless BP measurement. This study also offers insights into future research in cuffless BP measurement for tracking dynamic BP changes and over extended periods of time.
format Online
Article
Text
id pubmed-5599606
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-55996062017-09-15 Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation Ding, Xiaorong Yan, Bryan P. Zhang, Yuan-Ting Liu, Jing Zhao, Ni Tsang, Hon Ki Sci Rep Article Cuffless technique enables continuous blood pressure (BP) measurement in an unobtrusive manner, and thus has the potential to revolutionize the conventional cuff-based approaches. This study extends the pulse transit time (PTT) based cuffless BP measurement method by introducing a new indicator – the photoplethysmogram (PPG) intensity ratio (PIR). The performance of the models with PTT and PIR was comprehensively evaluated in comparison with six models that are based on sole PTT. The validation conducted on 33 subjects with and without hypertension, at rest and under various maneuvers with induced BP changes, and over an extended calibration interval, respectively. The results showed that, comparing to the PTT models, the proposed methods achieved better accuracy on each subject group at rest state and over 24 hours calibration interval. Although the BP estimation errors under dynamic maneuvers and over extended calibration interval were significantly increased for all methods, the proposed methods still outperformed the compared methods in the latter situation. These findings suggest that additional BP-related indicator other than PTT has added value for improving the accuracy of cuffless BP measurement. This study also offers insights into future research in cuffless BP measurement for tracking dynamic BP changes and over extended periods of time. Nature Publishing Group UK 2017-09-14 /pmc/articles/PMC5599606/ /pubmed/28912525 http://dx.doi.org/10.1038/s41598-017-11507-3 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Ding, Xiaorong
Yan, Bryan P.
Zhang, Yuan-Ting
Liu, Jing
Zhao, Ni
Tsang, Hon Ki
Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
title Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
title_full Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
title_fullStr Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
title_full_unstemmed Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
title_short Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
title_sort pulse transit time based continuous cuffless blood pressure estimation: a new extension and a comprehensive evaluation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5599606/
https://www.ncbi.nlm.nih.gov/pubmed/28912525
http://dx.doi.org/10.1038/s41598-017-11507-3
work_keys_str_mv AT dingxiaorong pulsetransittimebasedcontinuouscufflessbloodpressureestimationanewextensionandacomprehensiveevaluation
AT yanbryanp pulsetransittimebasedcontinuouscufflessbloodpressureestimationanewextensionandacomprehensiveevaluation
AT zhangyuanting pulsetransittimebasedcontinuouscufflessbloodpressureestimationanewextensionandacomprehensiveevaluation
AT liujing pulsetransittimebasedcontinuouscufflessbloodpressureestimationanewextensionandacomprehensiveevaluation
AT zhaoni pulsetransittimebasedcontinuouscufflessbloodpressureestimationanewextensionandacomprehensiveevaluation
AT tsanghonki pulsetransittimebasedcontinuouscufflessbloodpressureestimationanewextensionandacomprehensiveevaluation