Cargando…
SmartFlares fail to reflect their target transcripts levels
SmartFlare probes have recently emerged as a promising tool for visualisation and quantification of specific RNAs in living cells. They are supposed to overcome the common drawbacks of current methods for RNA analysis: the need of cell fixation or lysis, or the requirements for genetic manipulations...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5600982/ https://www.ncbi.nlm.nih.gov/pubmed/28916792 http://dx.doi.org/10.1038/s41598-017-11067-6 |
_version_ | 1783264307093438464 |
---|---|
author | Czarnek, Maria Bereta, Joanna |
author_facet | Czarnek, Maria Bereta, Joanna |
author_sort | Czarnek, Maria |
collection | PubMed |
description | SmartFlare probes have recently emerged as a promising tool for visualisation and quantification of specific RNAs in living cells. They are supposed to overcome the common drawbacks of current methods for RNA analysis: the need of cell fixation or lysis, or the requirements for genetic manipulations. In contrast to the traditional methods, SmartFlare probes are also presumed to provide information on RNA levels in single cells. Disappointingly, the results of our comprehensive study involving probes specific to five different transcripts, HMOX1, IL6, PTGS2, Nrg1, and ERBB4, deny the usefulness of SmartFlare probes for RNA analysis. We report a total lack of correlation between fluorescence intensities of SmartFlare probes and the levels of corresponding RNAs assessed by RT-qPCR. To ensure strong differences in the levels of analysed RNAs, their expression was modified via: (i) HMOX1-knockdown generated by CRISPR-Cas9 genome editing, (ii) hemin-mediated stimulation of HMOX1- and IL1β-mediated stimulation of IL6- and PTGS2 transcription, (iii) lentiviral vector-mediated Nrg1 overexpression. Additionally, ERBB4-specific SmartFlare probe failed to distinguish between ERBB4-expressing and non-expressing cell lines. Finally, we demonstrated that fluorescence intensity of HMOX1-specific SmartFlare probe corresponds to the efficacy of its uptake and/or accumulation. |
format | Online Article Text |
id | pubmed-5600982 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-56009822017-09-20 SmartFlares fail to reflect their target transcripts levels Czarnek, Maria Bereta, Joanna Sci Rep Article SmartFlare probes have recently emerged as a promising tool for visualisation and quantification of specific RNAs in living cells. They are supposed to overcome the common drawbacks of current methods for RNA analysis: the need of cell fixation or lysis, or the requirements for genetic manipulations. In contrast to the traditional methods, SmartFlare probes are also presumed to provide information on RNA levels in single cells. Disappointingly, the results of our comprehensive study involving probes specific to five different transcripts, HMOX1, IL6, PTGS2, Nrg1, and ERBB4, deny the usefulness of SmartFlare probes for RNA analysis. We report a total lack of correlation between fluorescence intensities of SmartFlare probes and the levels of corresponding RNAs assessed by RT-qPCR. To ensure strong differences in the levels of analysed RNAs, their expression was modified via: (i) HMOX1-knockdown generated by CRISPR-Cas9 genome editing, (ii) hemin-mediated stimulation of HMOX1- and IL1β-mediated stimulation of IL6- and PTGS2 transcription, (iii) lentiviral vector-mediated Nrg1 overexpression. Additionally, ERBB4-specific SmartFlare probe failed to distinguish between ERBB4-expressing and non-expressing cell lines. Finally, we demonstrated that fluorescence intensity of HMOX1-specific SmartFlare probe corresponds to the efficacy of its uptake and/or accumulation. Nature Publishing Group UK 2017-09-15 /pmc/articles/PMC5600982/ /pubmed/28916792 http://dx.doi.org/10.1038/s41598-017-11067-6 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Czarnek, Maria Bereta, Joanna SmartFlares fail to reflect their target transcripts levels |
title | SmartFlares fail to reflect their target transcripts levels |
title_full | SmartFlares fail to reflect their target transcripts levels |
title_fullStr | SmartFlares fail to reflect their target transcripts levels |
title_full_unstemmed | SmartFlares fail to reflect their target transcripts levels |
title_short | SmartFlares fail to reflect their target transcripts levels |
title_sort | smartflares fail to reflect their target transcripts levels |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5600982/ https://www.ncbi.nlm.nih.gov/pubmed/28916792 http://dx.doi.org/10.1038/s41598-017-11067-6 |
work_keys_str_mv | AT czarnekmaria smartflaresfailtoreflecttheirtargettranscriptslevels AT beretajoanna smartflaresfailtoreflecttheirtargettranscriptslevels |