Cargando…

Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique

Increased patient acceptance and widespread use have led to a greater demand for refabrication of existing maxillofacial prostheses exhibiting wear and tear. Refabricating an osseointegrated implant-retained silicone auricular prosthesis on the existing Hader bar is a challenging task if it is perfo...

Descripción completa

Detalles Bibliográficos
Autores principales: Kethireddy, Sanketh, Kethireddy, Keerthi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5601500/
https://www.ncbi.nlm.nih.gov/pubmed/28936047
http://dx.doi.org/10.4103/jips.jips_227_16
_version_ 1783264397824622592
author Kethireddy, Sanketh
Kethireddy, Keerthi
author_facet Kethireddy, Sanketh
Kethireddy, Keerthi
author_sort Kethireddy, Sanketh
collection PubMed
description Increased patient acceptance and widespread use have led to a greater demand for refabrication of existing maxillofacial prostheses exhibiting wear and tear. Refabricating an osseointegrated implant-retained silicone auricular prosthesis on the existing Hader bar is a challenging task if it is performed without removing it. Therefore, an attachment level impression method is utilized for the refabrication of a new prosthesis on an existing Hader bar framework without removing it from the patient's defect. This case report discusses a modification of the Mahidol University technique. This modification provides a simple, speedy, and convenient method through which the relation between the metal framework and attachments could be obtained precisely. This precision allowed for easy fabrication of the acrylic housing, which in turn results in better adaptation of the auricular prosthesis to the patient's face. Therefore, this technique offers advantages to both the prosthetist in fabrication and the patient in facilitating him continue to wear his existing implant-retained prosthesis during refabrication process.
format Online
Article
Text
id pubmed-5601500
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-56015002018-07-01 Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique Kethireddy, Sanketh Kethireddy, Keerthi J Indian Prosthodont Soc Case Report Increased patient acceptance and widespread use have led to a greater demand for refabrication of existing maxillofacial prostheses exhibiting wear and tear. Refabricating an osseointegrated implant-retained silicone auricular prosthesis on the existing Hader bar is a challenging task if it is performed without removing it. Therefore, an attachment level impression method is utilized for the refabrication of a new prosthesis on an existing Hader bar framework without removing it from the patient's defect. This case report discusses a modification of the Mahidol University technique. This modification provides a simple, speedy, and convenient method through which the relation between the metal framework and attachments could be obtained precisely. This precision allowed for easy fabrication of the acrylic housing, which in turn results in better adaptation of the auricular prosthesis to the patient's face. Therefore, this technique offers advantages to both the prosthetist in fabrication and the patient in facilitating him continue to wear his existing implant-retained prosthesis during refabrication process. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5601500/ /pubmed/28936047 http://dx.doi.org/10.4103/jips.jips_227_16 Text en Copyright: © 2017 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Case Report
Kethireddy, Sanketh
Kethireddy, Keerthi
Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_full Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_fullStr Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_full_unstemmed Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_short Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
title_sort refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5601500/
https://www.ncbi.nlm.nih.gov/pubmed/28936047
http://dx.doi.org/10.4103/jips.jips_227_16
work_keys_str_mv AT kethireddysanketh refabricationofanimplantretainedauricularprosthesisusingclipattachmentpickuptechnique
AT kethireddykeerthi refabricationofanimplantretainedauricularprosthesisusingclipattachmentpickuptechnique