Cargando…
Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique
Increased patient acceptance and widespread use have led to a greater demand for refabrication of existing maxillofacial prostheses exhibiting wear and tear. Refabricating an osseointegrated implant-retained silicone auricular prosthesis on the existing Hader bar is a challenging task if it is perfo...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5601500/ https://www.ncbi.nlm.nih.gov/pubmed/28936047 http://dx.doi.org/10.4103/jips.jips_227_16 |
_version_ | 1783264397824622592 |
---|---|
author | Kethireddy, Sanketh Kethireddy, Keerthi |
author_facet | Kethireddy, Sanketh Kethireddy, Keerthi |
author_sort | Kethireddy, Sanketh |
collection | PubMed |
description | Increased patient acceptance and widespread use have led to a greater demand for refabrication of existing maxillofacial prostheses exhibiting wear and tear. Refabricating an osseointegrated implant-retained silicone auricular prosthesis on the existing Hader bar is a challenging task if it is performed without removing it. Therefore, an attachment level impression method is utilized for the refabrication of a new prosthesis on an existing Hader bar framework without removing it from the patient's defect. This case report discusses a modification of the Mahidol University technique. This modification provides a simple, speedy, and convenient method through which the relation between the metal framework and attachments could be obtained precisely. This precision allowed for easy fabrication of the acrylic housing, which in turn results in better adaptation of the auricular prosthesis to the patient's face. Therefore, this technique offers advantages to both the prosthetist in fabrication and the patient in facilitating him continue to wear his existing implant-retained prosthesis during refabrication process. |
format | Online Article Text |
id | pubmed-5601500 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-56015002018-07-01 Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique Kethireddy, Sanketh Kethireddy, Keerthi J Indian Prosthodont Soc Case Report Increased patient acceptance and widespread use have led to a greater demand for refabrication of existing maxillofacial prostheses exhibiting wear and tear. Refabricating an osseointegrated implant-retained silicone auricular prosthesis on the existing Hader bar is a challenging task if it is performed without removing it. Therefore, an attachment level impression method is utilized for the refabrication of a new prosthesis on an existing Hader bar framework without removing it from the patient's defect. This case report discusses a modification of the Mahidol University technique. This modification provides a simple, speedy, and convenient method through which the relation between the metal framework and attachments could be obtained precisely. This precision allowed for easy fabrication of the acrylic housing, which in turn results in better adaptation of the auricular prosthesis to the patient's face. Therefore, this technique offers advantages to both the prosthetist in fabrication and the patient in facilitating him continue to wear his existing implant-retained prosthesis during refabrication process. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5601500/ /pubmed/28936047 http://dx.doi.org/10.4103/jips.jips_227_16 Text en Copyright: © 2017 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Kethireddy, Sanketh Kethireddy, Keerthi Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique |
title | Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique |
title_full | Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique |
title_fullStr | Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique |
title_full_unstemmed | Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique |
title_short | Refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique |
title_sort | refabrication of an implant-retained auricular prosthesis using clip attachment pickup technique |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5601500/ https://www.ncbi.nlm.nih.gov/pubmed/28936047 http://dx.doi.org/10.4103/jips.jips_227_16 |
work_keys_str_mv | AT kethireddysanketh refabricationofanimplantretainedauricularprosthesisusingclipattachmentpickuptechnique AT kethireddykeerthi refabricationofanimplantretainedauricularprosthesisusingclipattachmentpickuptechnique |