Cargando…
Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study
BACKGROUND: Tibial aperture fixation with a bioabsorbable interference screw is a popular fixation method in anterior cruciate ligament reconstruction (ACLR). An interference screw containing β-tricalcium phosphate (β-TCP) to improve bony integration and biocompatibility was recently introduced. Thi...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5602947/ https://www.ncbi.nlm.nih.gov/pubmed/28915914 http://dx.doi.org/10.1186/s12891-017-1757-0 |
_version_ | 1783264651241324544 |
---|---|
author | Wang, Joon Ho Lee, Eun Su Lee, Byung Hoon |
author_facet | Wang, Joon Ho Lee, Eun Su Lee, Byung Hoon |
author_sort | Wang, Joon Ho |
collection | PubMed |
description | BACKGROUND: Tibial aperture fixation with a bioabsorbable interference screw is a popular fixation method in anterior cruciate ligament reconstruction (ACLR). An interference screw containing β-tricalcium phosphate (β-TCP) to improve bony integration and biocompatibility was recently introduced. This study aims to compare the clinical outcomes and radiological results of tunnel enlargement effect between the 2 bioabsorbable fixative devices of pure poly-L-lactic acid (PLLA) interference screws and β-TCP-containing screws, for tibial interference fixation in ACLR using hamstring autografts. METHODS: Eighty consecutive patients who had undergone double-bundle ACLR between 2011 to 2012 were prospectively reviewed and randomly divided into two groups based on the type of tibial interference screw: 28 were assigned to the pure PLLA screw group (Group A), while the other 29 were assigned to the β-TCP-containing screw fixation group (Group B). Clinical evaluations and radiological analyses were conducted in both groups with a minimum 2- year follow-up. RESULTS: There was no significant difference in subjective or objective clinical outcome between the 2 groups. In radiological analyses, the use of a β-TCP-containing screw reduced tunnel widening in the portion of the tunnel with screw engagement compared to the pure PLLA screw, while the use of a β-TCP-containing screw resulted in greater tunnel enlargement in the proximal portion of the tunnel without screw engagement than use of a pure PLLA screw. CONCLUSION: Use of a β-TCP-containing interference screw in tibial aperture fixation reduced tunnel enlargement in the vicinity of the screw, whereas greater enlargement occurred proximal to the screw end relative to use of a pure PLLA interference screw. These paradoxical enlargements in use of β-TCP containing screws suggest that for reducing tunnel enlargement, the length of the interference screw should be as fit as possible with tunnel length in terms of using soft grafts. Level of Evidence: II, Prospectively comparative study. TRIAL REGISTRATION: Retrospectively registered with ClinicalTrials.gov. (NCT02754674), Date of trial registration: February 10, 2016. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12891-017-1757-0) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5602947 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-56029472017-09-20 Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study Wang, Joon Ho Lee, Eun Su Lee, Byung Hoon BMC Musculoskelet Disord Research Article BACKGROUND: Tibial aperture fixation with a bioabsorbable interference screw is a popular fixation method in anterior cruciate ligament reconstruction (ACLR). An interference screw containing β-tricalcium phosphate (β-TCP) to improve bony integration and biocompatibility was recently introduced. This study aims to compare the clinical outcomes and radiological results of tunnel enlargement effect between the 2 bioabsorbable fixative devices of pure poly-L-lactic acid (PLLA) interference screws and β-TCP-containing screws, for tibial interference fixation in ACLR using hamstring autografts. METHODS: Eighty consecutive patients who had undergone double-bundle ACLR between 2011 to 2012 were prospectively reviewed and randomly divided into two groups based on the type of tibial interference screw: 28 were assigned to the pure PLLA screw group (Group A), while the other 29 were assigned to the β-TCP-containing screw fixation group (Group B). Clinical evaluations and radiological analyses were conducted in both groups with a minimum 2- year follow-up. RESULTS: There was no significant difference in subjective or objective clinical outcome between the 2 groups. In radiological analyses, the use of a β-TCP-containing screw reduced tunnel widening in the portion of the tunnel with screw engagement compared to the pure PLLA screw, while the use of a β-TCP-containing screw resulted in greater tunnel enlargement in the proximal portion of the tunnel without screw engagement than use of a pure PLLA screw. CONCLUSION: Use of a β-TCP-containing interference screw in tibial aperture fixation reduced tunnel enlargement in the vicinity of the screw, whereas greater enlargement occurred proximal to the screw end relative to use of a pure PLLA interference screw. These paradoxical enlargements in use of β-TCP containing screws suggest that for reducing tunnel enlargement, the length of the interference screw should be as fit as possible with tunnel length in terms of using soft grafts. Level of Evidence: II, Prospectively comparative study. TRIAL REGISTRATION: Retrospectively registered with ClinicalTrials.gov. (NCT02754674), Date of trial registration: February 10, 2016. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12891-017-1757-0) contains supplementary material, which is available to authorized users. BioMed Central 2017-09-16 /pmc/articles/PMC5602947/ /pubmed/28915914 http://dx.doi.org/10.1186/s12891-017-1757-0 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Wang, Joon Ho Lee, Eun Su Lee, Byung Hoon Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study |
title | Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study |
title_full | Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study |
title_fullStr | Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study |
title_full_unstemmed | Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study |
title_short | Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study |
title_sort | paradoxical tunnel enlargement after acl reconstruction with hamstring autografts when using β-tcp containing interference screws for tibial aperture fixation- prospectively comparative study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5602947/ https://www.ncbi.nlm.nih.gov/pubmed/28915914 http://dx.doi.org/10.1186/s12891-017-1757-0 |
work_keys_str_mv | AT wangjoonho paradoxicaltunnelenlargementafteraclreconstructionwithhamstringautograftswhenusingbtcpcontaininginterferencescrewsfortibialaperturefixationprospectivelycomparativestudy AT leeeunsu paradoxicaltunnelenlargementafteraclreconstructionwithhamstringautograftswhenusingbtcpcontaininginterferencescrewsfortibialaperturefixationprospectivelycomparativestudy AT leebyunghoon paradoxicaltunnelenlargementafteraclreconstructionwithhamstringautograftswhenusingbtcpcontaininginterferencescrewsfortibialaperturefixationprospectivelycomparativestudy |