Cargando…
Development of an RP-HPLC-UV Method for Simultaneous Detection of Nimodipine and its Metabolite in Cerebrospinal Fluid of Rat
A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogen...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shaheed Beheshti University of Medical Sciences
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5603856/ https://www.ncbi.nlm.nih.gov/pubmed/28979302 |
_version_ | 1783264780094537728 |
---|---|
author | Sotoudegan, Farzaneh Amini, Mohsen Faizi, Mehrdad Aboofazeli, Reza |
author_facet | Sotoudegan, Farzaneh Amini, Mohsen Faizi, Mehrdad Aboofazeli, Reza |
author_sort | Sotoudegan, Farzaneh |
collection | PubMed |
description | A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogenous CSF peaks. Analysis was carried out on a Eurospher Performance (RP-C18, 250 × 4.6 mm) column and UV detection at 236 nm. The mobile phase consisted of acetonitrile and water (70:30 v/v, respectively) with a flow rate of 1 mL/min. Limit of detection was 0.1 μg/mL for OX-NM. The calibration curve was linear over the concentration range of 0.5-10 µg/mL and analytical recovery was more than 95%. The coefficients of variation for intra-day and inter-day assays were less than 5%. |
format | Online Article Text |
id | pubmed-5603856 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Shaheed Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-56038562017-10-04 Development of an RP-HPLC-UV Method for Simultaneous Detection of Nimodipine and its Metabolite in Cerebrospinal Fluid of Rat Sotoudegan, Farzaneh Amini, Mohsen Faizi, Mehrdad Aboofazeli, Reza Iran J Pharm Res Original Article A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogenous CSF peaks. Analysis was carried out on a Eurospher Performance (RP-C18, 250 × 4.6 mm) column and UV detection at 236 nm. The mobile phase consisted of acetonitrile and water (70:30 v/v, respectively) with a flow rate of 1 mL/min. Limit of detection was 0.1 μg/mL for OX-NM. The calibration curve was linear over the concentration range of 0.5-10 µg/mL and analytical recovery was more than 95%. The coefficients of variation for intra-day and inter-day assays were less than 5%. Shaheed Beheshti University of Medical Sciences 2017 /pmc/articles/PMC5603856/ /pubmed/28979302 Text en © 2017 by School of Pharmacy Shaheed Beheshti University of Medical Sciences and Health Services This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sotoudegan, Farzaneh Amini, Mohsen Faizi, Mehrdad Aboofazeli, Reza Development of an RP-HPLC-UV Method for Simultaneous Detection of Nimodipine and its Metabolite in Cerebrospinal Fluid of Rat |
title | Development of an RP-HPLC-UV Method for Simultaneous Detection of Nimodipine and its Metabolite in Cerebrospinal Fluid of Rat |
title_full | Development of an RP-HPLC-UV Method for Simultaneous Detection of Nimodipine and its Metabolite in Cerebrospinal Fluid of Rat |
title_fullStr | Development of an RP-HPLC-UV Method for Simultaneous Detection of Nimodipine and its Metabolite in Cerebrospinal Fluid of Rat |
title_full_unstemmed | Development of an RP-HPLC-UV Method for Simultaneous Detection of Nimodipine and its Metabolite in Cerebrospinal Fluid of Rat |
title_short | Development of an RP-HPLC-UV Method for Simultaneous Detection of Nimodipine and its Metabolite in Cerebrospinal Fluid of Rat |
title_sort | development of an rp-hplc-uv method for simultaneous detection of nimodipine and its metabolite in cerebrospinal fluid of rat |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5603856/ https://www.ncbi.nlm.nih.gov/pubmed/28979302 |
work_keys_str_mv | AT sotoudeganfarzaneh developmentofanrphplcuvmethodforsimultaneousdetectionofnimodipineanditsmetaboliteincerebrospinalfluidofrat AT aminimohsen developmentofanrphplcuvmethodforsimultaneousdetectionofnimodipineanditsmetaboliteincerebrospinalfluidofrat AT faizimehrdad developmentofanrphplcuvmethodforsimultaneousdetectionofnimodipineanditsmetaboliteincerebrospinalfluidofrat AT aboofazelireza developmentofanrphplcuvmethodforsimultaneousdetectionofnimodipineanditsmetaboliteincerebrospinalfluidofrat |