Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion
BACKGROUND: Decreasing the stiffness of locked plating constructs can promote natural fracture healing by controlled dynamization of the fracture. This biomechanical study compared the effect of 4 different stiffness reduction methods on interfragmentary motion by measuring axial motion and shear mo...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Journal of Orthopaedic Trauma
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5603978/ https://www.ncbi.nlm.nih.gov/pubmed/28657927 http://dx.doi.org/10.1097/BOT.0000000000000879 |
_version_ | 1783264797262872576 |
---|---|
author | Henschel, Julia Tsai, Stanley Fitzpatrick, Daniel C. Marsh, John L. Madey, Steven M. Bottlang, Michael |
author_facet | Henschel, Julia Tsai, Stanley Fitzpatrick, Daniel C. Marsh, John L. Madey, Steven M. Bottlang, Michael |
author_sort | Henschel, Julia |
collection | PubMed |
description | BACKGROUND: Decreasing the stiffness of locked plating constructs can promote natural fracture healing by controlled dynamization of the fracture. This biomechanical study compared the effect of 4 different stiffness reduction methods on interfragmentary motion by measuring axial motion and shear motion at the fracture site. METHODS: Distal femur locking plates were applied to bridge a metadiaphyseal fracture in femur surrogates. A locked construct with a short-bridge span served as the nondynamized control group (LOCKED). Four different methods for stiffness reduction were evaluated: replacing diaphyseal locking screws with nonlocked screws (NONLOCKED); bridge dynamization (BRIDGE) with 2 empty screw holes proximal to the fracture; screw dynamization with far cortical locking (FCL) screws; and plate dynamization with active locking plates (ACTIVE). Construct stiffness, axial motion, and shear motion at the fracture site were measured to characterize each dynamization methods. RESULTS: Compared with LOCKED control constructs, NONLOCKED constructs had a similar stiffness (P = 0.08), axial motion (P = 0.07), and shear motion (P = 0.97). BRIDGE constructs reduced stiffness by 45% compared with LOCKED constructs (P < 0.001), but interfragmentary motion was dominated by shear. Compared with LOCKED constructs, FCL and ACTIVE constructs reduced stiffness by 62% (P < 0.001) and 75% (P < 0.001), respectively, and significantly increased axial motion, but not shear motion. CONCLUSIONS: In a surrogate model of a distal femur fracture, replacing locked with nonlocked diaphyseal screws does not significantly decrease construct stiffness and does not enhance interfragmentary motion. A longer bridge span primarily increases shear motion, not axial motion. The use of FCL screws or active plating delivers axial dynamization without introducing shear motion. |
format | Online Article Text |
id | pubmed-5603978 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Journal of Orthopaedic Trauma |
record_format | MEDLINE/PubMed |
spelling | pubmed-56039782017-10-11 Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion Henschel, Julia Tsai, Stanley Fitzpatrick, Daniel C. Marsh, John L. Madey, Steven M. Bottlang, Michael J Orthop Trauma Original Article BACKGROUND: Decreasing the stiffness of locked plating constructs can promote natural fracture healing by controlled dynamization of the fracture. This biomechanical study compared the effect of 4 different stiffness reduction methods on interfragmentary motion by measuring axial motion and shear motion at the fracture site. METHODS: Distal femur locking plates were applied to bridge a metadiaphyseal fracture in femur surrogates. A locked construct with a short-bridge span served as the nondynamized control group (LOCKED). Four different methods for stiffness reduction were evaluated: replacing diaphyseal locking screws with nonlocked screws (NONLOCKED); bridge dynamization (BRIDGE) with 2 empty screw holes proximal to the fracture; screw dynamization with far cortical locking (FCL) screws; and plate dynamization with active locking plates (ACTIVE). Construct stiffness, axial motion, and shear motion at the fracture site were measured to characterize each dynamization methods. RESULTS: Compared with LOCKED control constructs, NONLOCKED constructs had a similar stiffness (P = 0.08), axial motion (P = 0.07), and shear motion (P = 0.97). BRIDGE constructs reduced stiffness by 45% compared with LOCKED constructs (P < 0.001), but interfragmentary motion was dominated by shear. Compared with LOCKED constructs, FCL and ACTIVE constructs reduced stiffness by 62% (P < 0.001) and 75% (P < 0.001), respectively, and significantly increased axial motion, but not shear motion. CONCLUSIONS: In a surrogate model of a distal femur fracture, replacing locked with nonlocked diaphyseal screws does not significantly decrease construct stiffness and does not enhance interfragmentary motion. A longer bridge span primarily increases shear motion, not axial motion. The use of FCL screws or active plating delivers axial dynamization without introducing shear motion. Journal of Orthopaedic Trauma 2017-10 2017-06-22 /pmc/articles/PMC5603978/ /pubmed/28657927 http://dx.doi.org/10.1097/BOT.0000000000000879 Text en Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Original Article Henschel, Julia Tsai, Stanley Fitzpatrick, Daniel C. Marsh, John L. Madey, Steven M. Bottlang, Michael Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion |
title | Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion |
title_full | Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion |
title_fullStr | Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion |
title_full_unstemmed | Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion |
title_short | Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion |
title_sort | comparison of 4 methods for dynamization of locking plates: differences in the amount and type of fracture motion |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5603978/ https://www.ncbi.nlm.nih.gov/pubmed/28657927 http://dx.doi.org/10.1097/BOT.0000000000000879 |
work_keys_str_mv | AT henscheljulia comparisonof4methodsfordynamizationoflockingplatesdifferencesintheamountandtypeoffracturemotion AT tsaistanley comparisonof4methodsfordynamizationoflockingplatesdifferencesintheamountandtypeoffracturemotion AT fitzpatrickdanielc comparisonof4methodsfordynamizationoflockingplatesdifferencesintheamountandtypeoffracturemotion AT marshjohnl comparisonof4methodsfordynamizationoflockingplatesdifferencesintheamountandtypeoffracturemotion AT madeystevenm comparisonof4methodsfordynamizationoflockingplatesdifferencesintheamountandtypeoffracturemotion AT bottlangmichael comparisonof4methodsfordynamizationoflockingplatesdifferencesintheamountandtypeoffracturemotion |