Cargando…

Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth

STATEMENT OF PROBLEM: The bond strength between restorative material and tooth structure is so important for conduction of durable restoration. Considering the recent attention to low shrinkage composite resins, evaluation of micro tensile bond strength of these materials would be valuable. OBJECTIV...

Descripción completa

Detalles Bibliográficos
Autores principales: M, Sharifi, S, Khoramian Tusi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Dental Biomaterials 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5608044/
https://www.ncbi.nlm.nih.gov/pubmed/28959759
_version_ 1783265373699702784
author M, Sharifi
S, Khoramian Tusi
author_facet M, Sharifi
S, Khoramian Tusi
author_sort M, Sharifi
collection PubMed
description STATEMENT OF PROBLEM: The bond strength between restorative material and tooth structure is so important for conduction of durable restoration. Considering the recent attention to low shrinkage composite resins, evaluation of micro tensile bond strength of these materials would be valuable. OBJECTIVES: To compare the microtensile bond strength of silorane composite resin (Filtek P90) with the conventional methacrylate composite (Filtek Z250) with and without applying acid etch before application of bonding system. MATERIALS AND METHODS: In this experimental study, 24 intact primary canines were used. After the dentin was exposed, the teeth were randomly divided into four groups as follows: the first group (silorane bond system + composite Filtek P90); the second group (etch + silorane bond system + composite Filtek P90); the third group (Single bond + composite Filtek Z250); and the fourth group (etch + Single bond + composite Filtek Z250). The teeth were cut on the longitudinal axis and the interface between the composite and dentin were grinded buccolingually and mesiodistally. The samples were subjected to a microtensile force until breakage. The obtained values were recorded in MPa; data were analyzed using One-way ANOVA and Tamhane’s T2 statistical tests. RESULTS: The average microtensile bond strength in all groups had a statistically significant difference with each other (all p < 0.05). The highest bond strength belonged to the second group (etch + silorane bond system + composite Filtek P90) and the lowest value was related to the third group (Single bond + composite Filtek Z250). CONCLUSIONS: As the second group (etch + silorane bond system + composite Filtek P90) exhibited higher microtensile bond strength, it may prove that using composite Filtek P90 is preferable to be used in primary dentin in comparison with composite Filtek Z250, and using etch + silorane bond system is more advantageous than single bond system.
format Online
Article
Text
id pubmed-5608044
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Journal of Dental Biomaterials
record_format MEDLINE/PubMed
spelling pubmed-56080442017-09-28 Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth M, Sharifi S, Khoramian Tusi J Dent Biomater Original Article STATEMENT OF PROBLEM: The bond strength between restorative material and tooth structure is so important for conduction of durable restoration. Considering the recent attention to low shrinkage composite resins, evaluation of micro tensile bond strength of these materials would be valuable. OBJECTIVES: To compare the microtensile bond strength of silorane composite resin (Filtek P90) with the conventional methacrylate composite (Filtek Z250) with and without applying acid etch before application of bonding system. MATERIALS AND METHODS: In this experimental study, 24 intact primary canines were used. After the dentin was exposed, the teeth were randomly divided into four groups as follows: the first group (silorane bond system + composite Filtek P90); the second group (etch + silorane bond system + composite Filtek P90); the third group (Single bond + composite Filtek Z250); and the fourth group (etch + Single bond + composite Filtek Z250). The teeth were cut on the longitudinal axis and the interface between the composite and dentin were grinded buccolingually and mesiodistally. The samples were subjected to a microtensile force until breakage. The obtained values were recorded in MPa; data were analyzed using One-way ANOVA and Tamhane’s T2 statistical tests. RESULTS: The average microtensile bond strength in all groups had a statistically significant difference with each other (all p < 0.05). The highest bond strength belonged to the second group (etch + silorane bond system + composite Filtek P90) and the lowest value was related to the third group (Single bond + composite Filtek Z250). CONCLUSIONS: As the second group (etch + silorane bond system + composite Filtek P90) exhibited higher microtensile bond strength, it may prove that using composite Filtek P90 is preferable to be used in primary dentin in comparison with composite Filtek Z250, and using etch + silorane bond system is more advantageous than single bond system. Journal of Dental Biomaterials 2016-12 /pmc/articles/PMC5608044/ /pubmed/28959759 Text en Copyright: © Journal of Dental Biomaterials http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
M, Sharifi
S, Khoramian Tusi
Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth
title Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth
title_full Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth
title_fullStr Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth
title_full_unstemmed Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth
title_short Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth
title_sort comparison of microtensile bond strength of silorane-based composite with the conventional methacrylate composite to the dentin of primary teeth
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5608044/
https://www.ncbi.nlm.nih.gov/pubmed/28959759
work_keys_str_mv AT msharifi comparisonofmicrotensilebondstrengthofsiloranebasedcompositewiththeconventionalmethacrylatecompositetothedentinofprimaryteeth
AT skhoramiantusi comparisonofmicrotensilebondstrengthofsiloranebasedcompositewiththeconventionalmethacrylatecompositetothedentinofprimaryteeth