Assessing the Effect of Dental Implants Thread Design on Distribution of Stress in Impact Loadings Using Three Dimensional Finite Element Method
STATEMENT OF PROBLEM: Impacts and accidents are considered as the main fac- tors in losing the teeth, so the analysis and design of the implants that they can be more resistant against impacts is very important. One of the important nu- merical methods having widespread application in various fields...
Autores principales: | I, Zarei, S, Khajehpour, A, Sabouri, AZ, Haghnegahdar, K, Jafari |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Journal of Dental Biomaterials
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5608057/ https://www.ncbi.nlm.nih.gov/pubmed/28959748 |
Ejemplares similares
-
Three-Dimensional Finite Element Investigation into Effects of Implant Thread Design and Loading Rate on Stress Distribution in Dental Implants and Anisotropic Bone
por: Alemayehu, Dawit-Bogale, et al.
Publicado: (2021) -
Influence of three different implant thread designs on stress distribution: A three-dimensional finite element analysis
por: Oswal, Mansi Manish, et al.
Publicado: (2016) -
Three-dimensional optimization and sensitivity analysis of dental implant thread parameters using finite element analysis
por: Geramizadeh, Maryam, et al.
Publicado: (2018) -
Biomechanical Effect of an Exposed Dental Implant’s First Thread: A Three-Dimensional Finite Element Analysis Study
por: Hudieb, Malik Ismail, et al.
Publicado: (2019) -
The influence of thread geometry on biomechanical load transfer to bone: A finite element analysis comparing two implant thread designs
por: Herekar, Manisha G, et al.
Publicado: (2014)