Cargando…
Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T
PURPOSE: Multi-slice ungated double inversion recovery has been proposed as an alternative time-efficient and effective sequence for black-blood carotid imaging. The purpose of this study is to evaluate the comparative repeatability of this multi-contrast sequence with respect to a single slice doub...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese Society for Magnetic Resonance in Medicine
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5608122/ https://www.ncbi.nlm.nih.gov/pubmed/26549163 http://dx.doi.org/10.2463/mrms.mp.2014-0133 |
_version_ | 1783265388322095104 |
---|---|
author | ZHU, Chengcheng GRAVES, Martin J SADAT, Umar YOUNG, Victoria E GILLARD, Jonathan H PATTERSON, Andrew J |
author_facet | ZHU, Chengcheng GRAVES, Martin J SADAT, Umar YOUNG, Victoria E GILLARD, Jonathan H PATTERSON, Andrew J |
author_sort | ZHU, Chengcheng |
collection | PubMed |
description | PURPOSE: Multi-slice ungated double inversion recovery has been proposed as an alternative time-efficient and effective sequence for black-blood carotid imaging. The purpose of this study is to evaluate the comparative repeatability of this multi-contrast sequence with respect to a single slice double inversion recovery prepared gated sequence. MATERIALS AND METHODS: Ten healthy volunteers and three patients with Doppler ultrasound defined carotid artery stenosis >30% were recruited. T(1)-weighted (T(1)W) and T(2)W fast spin-echo (FSE) images were acquired centered at the carotid bifurcation with and without cardiac gating. Repeat imaging was performed without patient repositioning to determine the variations in vessel wall measurement and signal intensity due to gating, while negating variations as a result of slice misalignment and anatomical displacement relative to the receiver coil. The distributions and the repeatability of lumen area, vessel wall area, signal and contrast-to-noise ratio (SNR/CNR) of the vessel wall and adjacent muscle were reported. RESULTS: The T(1)W ungated sequence generally had comparable wall SNR/CNR with respect to the gated sequence, however the muscle SNR was lower (P = 0.013). The T(2)W ungated multi-slice sequence had lower SNR/CNR than the gated single slice sequence (P < 0.001), but with equivalent effective wall CNR (P = 0.735). Vessel area measurements using the gated/ungated sequences were equivalent. Ungated sequences had better repeatability in SNR/CNR than the gated sequences with borderline and statistically significant differences. The repeatability of T(2)W wall area measurement was better using the ungated sequences (P = 0.02), and the repeatability of the remaining vessel area measurements were equivalent. CONCLUSIONS: Ungated sequences can achieve comparable SNR/CNR and equivalent carotid vessel area measurements than gated sequences with improved repeatability of SNR/CNR. Ungated sequences are good alternatives of gated sequences for vessel area measurement and plaque composition quantification. |
format | Online Article Text |
id | pubmed-5608122 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Japanese Society for Magnetic Resonance in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-56081222017-10-23 Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T ZHU, Chengcheng GRAVES, Martin J SADAT, Umar YOUNG, Victoria E GILLARD, Jonathan H PATTERSON, Andrew J Magn Reson Med Sci Major Paper PURPOSE: Multi-slice ungated double inversion recovery has been proposed as an alternative time-efficient and effective sequence for black-blood carotid imaging. The purpose of this study is to evaluate the comparative repeatability of this multi-contrast sequence with respect to a single slice double inversion recovery prepared gated sequence. MATERIALS AND METHODS: Ten healthy volunteers and three patients with Doppler ultrasound defined carotid artery stenosis >30% were recruited. T(1)-weighted (T(1)W) and T(2)W fast spin-echo (FSE) images were acquired centered at the carotid bifurcation with and without cardiac gating. Repeat imaging was performed without patient repositioning to determine the variations in vessel wall measurement and signal intensity due to gating, while negating variations as a result of slice misalignment and anatomical displacement relative to the receiver coil. The distributions and the repeatability of lumen area, vessel wall area, signal and contrast-to-noise ratio (SNR/CNR) of the vessel wall and adjacent muscle were reported. RESULTS: The T(1)W ungated sequence generally had comparable wall SNR/CNR with respect to the gated sequence, however the muscle SNR was lower (P = 0.013). The T(2)W ungated multi-slice sequence had lower SNR/CNR than the gated single slice sequence (P < 0.001), but with equivalent effective wall CNR (P = 0.735). Vessel area measurements using the gated/ungated sequences were equivalent. Ungated sequences had better repeatability in SNR/CNR than the gated sequences with borderline and statistically significant differences. The repeatability of T(2)W wall area measurement was better using the ungated sequences (P = 0.02), and the repeatability of the remaining vessel area measurements were equivalent. CONCLUSIONS: Ungated sequences can achieve comparable SNR/CNR and equivalent carotid vessel area measurements than gated sequences with improved repeatability of SNR/CNR. Ungated sequences are good alternatives of gated sequences for vessel area measurement and plaque composition quantification. Japanese Society for Magnetic Resonance in Medicine 2015-11-06 /pmc/articles/PMC5608122/ /pubmed/26549163 http://dx.doi.org/10.2463/mrms.mp.2014-0133 Text en © 2015 Japanese Society for Magnetic Resonance in Medicine http://creativecommons.org/licenses/by/3.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License. |
spellingShingle | Major Paper ZHU, Chengcheng GRAVES, Martin J SADAT, Umar YOUNG, Victoria E GILLARD, Jonathan H PATTERSON, Andrew J Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T |
title | Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T |
title_full | Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T |
title_fullStr | Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T |
title_full_unstemmed | Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T |
title_short | Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T |
title_sort | comparison of gated and ungated black-blood fast spin-echo mri of carotid vessel wall at 3t |
topic | Major Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5608122/ https://www.ncbi.nlm.nih.gov/pubmed/26549163 http://dx.doi.org/10.2463/mrms.mp.2014-0133 |
work_keys_str_mv | AT zhuchengcheng comparisonofgatedandungatedblackbloodfastspinechomriofcarotidvesselwallat3t AT gravesmartinj comparisonofgatedandungatedblackbloodfastspinechomriofcarotidvesselwallat3t AT sadatumar comparisonofgatedandungatedblackbloodfastspinechomriofcarotidvesselwallat3t AT youngvictoriae comparisonofgatedandungatedblackbloodfastspinechomriofcarotidvesselwallat3t AT gillardjonathanh comparisonofgatedandungatedblackbloodfastspinechomriofcarotidvesselwallat3t AT pattersonandrewj comparisonofgatedandungatedblackbloodfastspinechomriofcarotidvesselwallat3t |