Cargando…
Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature
ABSTRACT: Purpose Ingrowth of fibroblasts in a polypropylene mesh may cause contraction and a later recurrence. We assessed mesh contraction in intraabdominal and retromuscular implantation after incisional hernia repair. METHODS: A cohort of patients within an RCT on laparoscopic (LHR) versus open...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Paris
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5608776/ https://www.ncbi.nlm.nih.gov/pubmed/28634690 http://dx.doi.org/10.1007/s10029-017-1624-9 |
_version_ | 1783265492456177664 |
---|---|
author | Rogmark, P. Ekberg, O. Montgomery, A. |
author_facet | Rogmark, P. Ekberg, O. Montgomery, A. |
author_sort | Rogmark, P. |
collection | PubMed |
description | ABSTRACT: Purpose Ingrowth of fibroblasts in a polypropylene mesh may cause contraction and a later recurrence. We assessed mesh contraction in intraabdominal and retromuscular implantation after incisional hernia repair. METHODS: A cohort of patients within an RCT on laparoscopic (LHR) versus open hernia repair (OHR) had their mesh borders marked with metal clips. X-ray was performed on postoperative day 1 and after 1 year. Total length, width, and dislocation were measured. A tacker fixated large-pore polypropylene mesh was used in LHR, and a retromuscular small-pore heavy-weight mesh was sutured to the midline in OHR. Patient’s pain was assessed before surgery and after 1 year. RESULTS: For analysis 37/47 patients remained: 20 LHR and 17 OHR. Hernia defect area was median 41 cm(2) in LHR and 25 cm(2) in OHR (p < 0.140). Implanted mesh size was 300 cm(2) for LHR and 240 cm(2) for OHR (p < 0.341). After 1 year the mesh area decreased by 4.4% and 0.5% in LHR and OHR, respectively (p < 0.063). Longitudinal distance decreased by 2.8% in LHR and by 2.6% in OHR (p < 0.269). Transverse distance decreased by 1.6% in LHR but increased by 3.1% in OHR (p < 0.005). Dislocation was seen in four LHR and one OHR. Two recurrent and one port-site hernia were diagnosed after LHR. Measurements between observers were identical in 58% and consensus was made in the remainder. Pain was not correlated to mesh area change. CONCLUSIONS: Mesh contraction after 1 year is not a clinical issue for an intraperitoneal large-pore mesh or a retromuscular small-pore mesh. It is not correlated to postoperative pain. |
format | Online Article Text |
id | pubmed-5608776 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer Paris |
record_format | MEDLINE/PubMed |
spelling | pubmed-56087762017-10-05 Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature Rogmark, P. Ekberg, O. Montgomery, A. Hernia Original Article ABSTRACT: Purpose Ingrowth of fibroblasts in a polypropylene mesh may cause contraction and a later recurrence. We assessed mesh contraction in intraabdominal and retromuscular implantation after incisional hernia repair. METHODS: A cohort of patients within an RCT on laparoscopic (LHR) versus open hernia repair (OHR) had their mesh borders marked with metal clips. X-ray was performed on postoperative day 1 and after 1 year. Total length, width, and dislocation were measured. A tacker fixated large-pore polypropylene mesh was used in LHR, and a retromuscular small-pore heavy-weight mesh was sutured to the midline in OHR. Patient’s pain was assessed before surgery and after 1 year. RESULTS: For analysis 37/47 patients remained: 20 LHR and 17 OHR. Hernia defect area was median 41 cm(2) in LHR and 25 cm(2) in OHR (p < 0.140). Implanted mesh size was 300 cm(2) for LHR and 240 cm(2) for OHR (p < 0.341). After 1 year the mesh area decreased by 4.4% and 0.5% in LHR and OHR, respectively (p < 0.063). Longitudinal distance decreased by 2.8% in LHR and by 2.6% in OHR (p < 0.269). Transverse distance decreased by 1.6% in LHR but increased by 3.1% in OHR (p < 0.005). Dislocation was seen in four LHR and one OHR. Two recurrent and one port-site hernia were diagnosed after LHR. Measurements between observers were identical in 58% and consensus was made in the remainder. Pain was not correlated to mesh area change. CONCLUSIONS: Mesh contraction after 1 year is not a clinical issue for an intraperitoneal large-pore mesh or a retromuscular small-pore mesh. It is not correlated to postoperative pain. Springer Paris 2017-06-20 2017 /pmc/articles/PMC5608776/ /pubmed/28634690 http://dx.doi.org/10.1007/s10029-017-1624-9 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Rogmark, P. Ekberg, O. Montgomery, A. Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature |
title | Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature |
title_full | Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature |
title_fullStr | Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature |
title_full_unstemmed | Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature |
title_short | Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature |
title_sort | long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5608776/ https://www.ncbi.nlm.nih.gov/pubmed/28634690 http://dx.doi.org/10.1007/s10029-017-1624-9 |
work_keys_str_mv | AT rogmarkp longtermretromuscularandintraperitonealmeshsizechangeswithinarandomizedcontrolledtrialonincisionalherniarepairincludingareviewoftheliterature AT ekbergo longtermretromuscularandintraperitonealmeshsizechangeswithinarandomizedcontrolledtrialonincisionalherniarepairincludingareviewoftheliterature AT montgomerya longtermretromuscularandintraperitonealmeshsizechangeswithinarandomizedcontrolledtrialonincisionalherniarepairincludingareviewoftheliterature |