Cargando…

Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature

ABSTRACT: Purpose Ingrowth of fibroblasts in a polypropylene mesh may cause contraction and a later recurrence. We assessed mesh contraction in intraabdominal and retromuscular implantation after incisional hernia repair. METHODS: A cohort of patients within an RCT on laparoscopic (LHR) versus open...

Descripción completa

Detalles Bibliográficos
Autores principales: Rogmark, P., Ekberg, O., Montgomery, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Paris 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5608776/
https://www.ncbi.nlm.nih.gov/pubmed/28634690
http://dx.doi.org/10.1007/s10029-017-1624-9
_version_ 1783265492456177664
author Rogmark, P.
Ekberg, O.
Montgomery, A.
author_facet Rogmark, P.
Ekberg, O.
Montgomery, A.
author_sort Rogmark, P.
collection PubMed
description ABSTRACT: Purpose Ingrowth of fibroblasts in a polypropylene mesh may cause contraction and a later recurrence. We assessed mesh contraction in intraabdominal and retromuscular implantation after incisional hernia repair. METHODS: A cohort of patients within an RCT on laparoscopic (LHR) versus open hernia repair (OHR) had their mesh borders marked with metal clips. X-ray was performed on postoperative day 1 and after 1 year. Total length, width, and dislocation were measured. A tacker fixated large-pore polypropylene mesh was used in LHR, and a retromuscular small-pore heavy-weight mesh was sutured to the midline in OHR. Patient’s pain was assessed before surgery and after 1 year. RESULTS: For analysis 37/47 patients remained: 20 LHR and 17 OHR. Hernia defect area was median 41 cm(2) in LHR and 25 cm(2) in OHR (p < 0.140). Implanted mesh size was 300 cm(2) for LHR and 240 cm(2) for OHR (p < 0.341). After 1 year the mesh area decreased by 4.4% and 0.5% in LHR and OHR, respectively (p < 0.063). Longitudinal distance decreased by 2.8% in LHR and by 2.6% in OHR (p < 0.269). Transverse distance decreased by 1.6% in LHR but increased by 3.1% in OHR (p < 0.005). Dislocation was seen in four LHR and one OHR. Two recurrent and one port-site hernia were diagnosed after LHR. Measurements between observers were identical in 58% and consensus was made in the remainder. Pain was not correlated to mesh area change. CONCLUSIONS: Mesh contraction after 1 year is not a clinical issue for an intraperitoneal large-pore mesh or a retromuscular small-pore mesh. It is not correlated to postoperative pain.
format Online
Article
Text
id pubmed-5608776
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Paris
record_format MEDLINE/PubMed
spelling pubmed-56087762017-10-05 Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature Rogmark, P. Ekberg, O. Montgomery, A. Hernia Original Article ABSTRACT: Purpose Ingrowth of fibroblasts in a polypropylene mesh may cause contraction and a later recurrence. We assessed mesh contraction in intraabdominal and retromuscular implantation after incisional hernia repair. METHODS: A cohort of patients within an RCT on laparoscopic (LHR) versus open hernia repair (OHR) had their mesh borders marked with metal clips. X-ray was performed on postoperative day 1 and after 1 year. Total length, width, and dislocation were measured. A tacker fixated large-pore polypropylene mesh was used in LHR, and a retromuscular small-pore heavy-weight mesh was sutured to the midline in OHR. Patient’s pain was assessed before surgery and after 1 year. RESULTS: For analysis 37/47 patients remained: 20 LHR and 17 OHR. Hernia defect area was median 41 cm(2) in LHR and 25 cm(2) in OHR (p < 0.140). Implanted mesh size was 300 cm(2) for LHR and 240 cm(2) for OHR (p < 0.341). After 1 year the mesh area decreased by 4.4% and 0.5% in LHR and OHR, respectively (p < 0.063). Longitudinal distance decreased by 2.8% in LHR and by 2.6% in OHR (p < 0.269). Transverse distance decreased by 1.6% in LHR but increased by 3.1% in OHR (p < 0.005). Dislocation was seen in four LHR and one OHR. Two recurrent and one port-site hernia were diagnosed after LHR. Measurements between observers were identical in 58% and consensus was made in the remainder. Pain was not correlated to mesh area change. CONCLUSIONS: Mesh contraction after 1 year is not a clinical issue for an intraperitoneal large-pore mesh or a retromuscular small-pore mesh. It is not correlated to postoperative pain. Springer Paris 2017-06-20 2017 /pmc/articles/PMC5608776/ /pubmed/28634690 http://dx.doi.org/10.1007/s10029-017-1624-9 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Rogmark, P.
Ekberg, O.
Montgomery, A.
Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature
title Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature
title_full Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature
title_fullStr Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature
title_full_unstemmed Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature
title_short Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature
title_sort long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5608776/
https://www.ncbi.nlm.nih.gov/pubmed/28634690
http://dx.doi.org/10.1007/s10029-017-1624-9
work_keys_str_mv AT rogmarkp longtermretromuscularandintraperitonealmeshsizechangeswithinarandomizedcontrolledtrialonincisionalherniarepairincludingareviewoftheliterature
AT ekbergo longtermretromuscularandintraperitonealmeshsizechangeswithinarandomizedcontrolledtrialonincisionalherniarepairincludingareviewoftheliterature
AT montgomerya longtermretromuscularandintraperitonealmeshsizechangeswithinarandomizedcontrolledtrialonincisionalherniarepairincludingareviewoftheliterature