Cargando…

Sequential changes of arterial spin-labeling perfusion MR images with dual postlabeling delay following reconstructive surgery for giant internal carotid artery aneurysm

BACKGROUND: Arterial spin-labeling magnetic resonance perfusion imaging (ASL-MRI) allows noninvasive measurement of cerebral blood flow (CBF) but depends on arterial transit time (ATT). To overcome this problem, we developed a simple ASL technique with dual postlabeling delay (PLD) settings. In addi...

Descripción completa

Detalles Bibliográficos
Autores principales: Shimogawa, Takafumi, Morioka, Takato, Akiyama, Tomoaki, Haga, Sei, Arakawa, Shuji, Sayama, Tetsuro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5609433/
https://www.ncbi.nlm.nih.gov/pubmed/28966828
http://dx.doi.org/10.4103/sni.sni_73_17
Descripción
Sumario:BACKGROUND: Arterial spin-labeling magnetic resonance perfusion imaging (ASL-MRI) allows noninvasive measurement of cerebral blood flow (CBF) but depends on arterial transit time (ATT). To overcome this problem, we developed a simple ASL technique with dual postlabeling delay (PLD) settings. In addition to the routinely used PLD of 1.5 seconds, we selected another PLD of 2.5 seconds to assess slowly streaming blood flow and detect arterial transit artifacts (ATAs) resulting from stagnant intravascular magnetically labeled spins. CASE DESCRIPTION: We validated the dual PLD method with digital subtraction angiography (DSA) findings in a patient with an unruptured right giant internal carotid artery (ICA) aneurysm who underwent proximal ligation of the right cervical ICA followed by right superficial temporal artery–middle cerebral artery anastomosis. The giant aneurysm was detected as a strongly hyperintense signal area of ATA using both values of PLD. Decreased signal in the right hemisphere at PLD 1.5 seconds was somewhat improved at PLD 2.5 seconds. DSA revealed that this laterality resulted from the different ATT values between hemispheres due to stagnation of the labeled spin within the aneurysm. Postoperatively, with gradual but complete thrombosis and regression of the aneurysm, the size of the ASL hyperintense signal area decreased markedly. At postoperative 2 years, the aneurysm was not demonstrated as an ATA; furthermore, the decreased signals in the right hemisphere at PLD 1.5 seconds had mostly improved. CONCLUSION: Serial ASL-MRI with dual PLDs could show dynamic changes of giant aneurysms and the associated hemodynamic state following the surgery.