Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection

BACKGROUNDS: With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet f...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoshida, Naohisa, Toyonaga, Takashi, Murakami, Takaaki, Hirose, Ryohei, Ogiso, Kiyoshi, Inada, Yutaka, Rani, Rafiz Abdul, Naito, Yuji, Kishimoto, Mitsuo, Ohara, Yoshiko, Azuma, Takeshi, Itoh, Yoshito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5610827/
https://www.ncbi.nlm.nih.gov/pubmed/29081793
http://dx.doi.org/10.1155/2017/5897369
_version_ 1783265832808218624
author Yoshida, Naohisa
Toyonaga, Takashi
Murakami, Takaaki
Hirose, Ryohei
Ogiso, Kiyoshi
Inada, Yutaka
Rani, Rafiz Abdul
Naito, Yuji
Kishimoto, Mitsuo
Ohara, Yoshiko
Azuma, Takeshi
Itoh, Yoshito
author_facet Yoshida, Naohisa
Toyonaga, Takashi
Murakami, Takaaki
Hirose, Ryohei
Ogiso, Kiyoshi
Inada, Yutaka
Rani, Rafiz Abdul
Naito, Yuji
Kishimoto, Mitsuo
Ohara, Yoshiko
Azuma, Takeshi
Itoh, Yoshito
author_sort Yoshida, Naohisa
collection PubMed
description BACKGROUNDS: With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). METHODS: In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. RESULTS: The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1–28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. CONCLUSIONS: Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.
format Online
Article
Text
id pubmed-5610827
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-56108272017-10-29 Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection Yoshida, Naohisa Toyonaga, Takashi Murakami, Takaaki Hirose, Ryohei Ogiso, Kiyoshi Inada, Yutaka Rani, Rafiz Abdul Naito, Yuji Kishimoto, Mitsuo Ohara, Yoshiko Azuma, Takeshi Itoh, Yoshito Gastroenterol Res Pract Research Article BACKGROUNDS: With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). METHODS: In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. RESULTS: The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1–28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. CONCLUSIONS: Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results. Hindawi 2017 2017-09-10 /pmc/articles/PMC5610827/ /pubmed/29081793 http://dx.doi.org/10.1155/2017/5897369 Text en Copyright © 2017 Naohisa Yoshida et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yoshida, Naohisa
Toyonaga, Takashi
Murakami, Takaaki
Hirose, Ryohei
Ogiso, Kiyoshi
Inada, Yutaka
Rani, Rafiz Abdul
Naito, Yuji
Kishimoto, Mitsuo
Ohara, Yoshiko
Azuma, Takeshi
Itoh, Yoshito
Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection
title Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection
title_full Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection
title_fullStr Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection
title_full_unstemmed Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection
title_short Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection
title_sort efficacy of a novel narrow knife with water jet function for colorectal endoscopic submucosal dissection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5610827/
https://www.ncbi.nlm.nih.gov/pubmed/29081793
http://dx.doi.org/10.1155/2017/5897369
work_keys_str_mv AT yoshidanaohisa efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT toyonagatakashi efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT murakamitakaaki efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT hiroseryohei efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT ogisokiyoshi efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT inadayutaka efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT ranirafizabdul efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT naitoyuji efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT kishimotomitsuo efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT oharayoshiko efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT azumatakeshi efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection
AT itohyoshito efficacyofanovelnarrowknifewithwaterjetfunctionforcolorectalendoscopicsubmucosaldissection