Adult human dermal fibroblasts exposed to nanosecond electrical pulses exhibit genetic biomarkers of mechanical stress

BACKGROUND: Exposure of cells to very short (<1 µs) electric pulses in the megavolt/meter range have been shown to cause a multitude of effects, both physical and molecular in nature. Physically, nanosecond electrical pulses (nsEP) can cause disruption of the plasma membrane, cellular swelling, s...

Descripción completa

Detalles Bibliográficos
Autores principales: Roth, Caleb C., Glickman, Randolph D., Martens, Stacey L., Echchgadda, Ibtissam, Beier, Hope T., Barnes, Ronald A., Ibey, Bennett L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5614618/
https://www.ncbi.nlm.nih.gov/pubmed/28956017
http://dx.doi.org/10.1016/j.bbrep.2017.01.007
_version_ 1783266430769168384
author Roth, Caleb C.
Glickman, Randolph D.
Martens, Stacey L.
Echchgadda, Ibtissam
Beier, Hope T.
Barnes, Ronald A.
Ibey, Bennett L.
author_facet Roth, Caleb C.
Glickman, Randolph D.
Martens, Stacey L.
Echchgadda, Ibtissam
Beier, Hope T.
Barnes, Ronald A.
Ibey, Bennett L.
author_sort Roth, Caleb C.
collection PubMed
description BACKGROUND: Exposure of cells to very short (<1 µs) electric pulses in the megavolt/meter range have been shown to cause a multitude of effects, both physical and molecular in nature. Physically, nanosecond electrical pulses (nsEP) can cause disruption of the plasma membrane, cellular swelling, shrinking and blebbing. Molecularly, nsEP have been shown to activate signaling pathways, produce oxidative stress, stimulate hormone secretion and induce both apoptotic and necrotic death. We hypothesize that studying the genetic response of primary human dermal fibroblasts exposed to nsEP, will gain insight into the molecular mechanism(s) either activated directly by nsEP, or indirectly through electrophysiology interactions. METHODS: Microarray analysis in conjunction with quantitative real time polymerase chain reaction (qRT-PCR) was used to screen and validate genes selectively upregulated in response to nsEP exposure. RESULTS: Expression profiles of 486 genes were found to be significantly changed by nsEP exposure. 50% of the top 20 responding genes coded for proteins located in two distinct cellular locations, the plasma membrane and the nucleus. Further analysis of five of the top 20 upregulated genes indicated that the HDFa cells’ response to nsEP exposure included many elements of a mechanical stress response. CONCLUSIONS: We found that several genes, some of which are mechanosensitive, were selectively upregulated due to nsEP exposure. This genetic response appears to be a primary response to the stimuli and not a secondary response to cellular swelling. GENERAL SIGNIFICANCE: This work provides strong evidence that cells exposed to nsEP interpret the insult as a mechanical stress.
format Online
Article
Text
id pubmed-5614618
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-56146182017-09-27 Adult human dermal fibroblasts exposed to nanosecond electrical pulses exhibit genetic biomarkers of mechanical stress Roth, Caleb C. Glickman, Randolph D. Martens, Stacey L. Echchgadda, Ibtissam Beier, Hope T. Barnes, Ronald A. Ibey, Bennett L. Biochem Biophys Rep Research Article BACKGROUND: Exposure of cells to very short (<1 µs) electric pulses in the megavolt/meter range have been shown to cause a multitude of effects, both physical and molecular in nature. Physically, nanosecond electrical pulses (nsEP) can cause disruption of the plasma membrane, cellular swelling, shrinking and blebbing. Molecularly, nsEP have been shown to activate signaling pathways, produce oxidative stress, stimulate hormone secretion and induce both apoptotic and necrotic death. We hypothesize that studying the genetic response of primary human dermal fibroblasts exposed to nsEP, will gain insight into the molecular mechanism(s) either activated directly by nsEP, or indirectly through electrophysiology interactions. METHODS: Microarray analysis in conjunction with quantitative real time polymerase chain reaction (qRT-PCR) was used to screen and validate genes selectively upregulated in response to nsEP exposure. RESULTS: Expression profiles of 486 genes were found to be significantly changed by nsEP exposure. 50% of the top 20 responding genes coded for proteins located in two distinct cellular locations, the plasma membrane and the nucleus. Further analysis of five of the top 20 upregulated genes indicated that the HDFa cells’ response to nsEP exposure included many elements of a mechanical stress response. CONCLUSIONS: We found that several genes, some of which are mechanosensitive, were selectively upregulated due to nsEP exposure. This genetic response appears to be a primary response to the stimuli and not a secondary response to cellular swelling. GENERAL SIGNIFICANCE: This work provides strong evidence that cells exposed to nsEP interpret the insult as a mechanical stress. Elsevier 2017-01-25 /pmc/articles/PMC5614618/ /pubmed/28956017 http://dx.doi.org/10.1016/j.bbrep.2017.01.007 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Roth, Caleb C.
Glickman, Randolph D.
Martens, Stacey L.
Echchgadda, Ibtissam
Beier, Hope T.
Barnes, Ronald A.
Ibey, Bennett L.
Adult human dermal fibroblasts exposed to nanosecond electrical pulses exhibit genetic biomarkers of mechanical stress
title Adult human dermal fibroblasts exposed to nanosecond electrical pulses exhibit genetic biomarkers of mechanical stress
title_full Adult human dermal fibroblasts exposed to nanosecond electrical pulses exhibit genetic biomarkers of mechanical stress
title_fullStr Adult human dermal fibroblasts exposed to nanosecond electrical pulses exhibit genetic biomarkers of mechanical stress
title_full_unstemmed Adult human dermal fibroblasts exposed to nanosecond electrical pulses exhibit genetic biomarkers of mechanical stress
title_short Adult human dermal fibroblasts exposed to nanosecond electrical pulses exhibit genetic biomarkers of mechanical stress
title_sort adult human dermal fibroblasts exposed to nanosecond electrical pulses exhibit genetic biomarkers of mechanical stress
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5614618/
https://www.ncbi.nlm.nih.gov/pubmed/28956017
http://dx.doi.org/10.1016/j.bbrep.2017.01.007
work_keys_str_mv AT rothcalebc adulthumandermalfibroblastsexposedtonanosecondelectricalpulsesexhibitgeneticbiomarkersofmechanicalstress
AT glickmanrandolphd adulthumandermalfibroblastsexposedtonanosecondelectricalpulsesexhibitgeneticbiomarkersofmechanicalstress
AT martensstaceyl adulthumandermalfibroblastsexposedtonanosecondelectricalpulsesexhibitgeneticbiomarkersofmechanicalstress
AT echchgaddaibtissam adulthumandermalfibroblastsexposedtonanosecondelectricalpulsesexhibitgeneticbiomarkersofmechanicalstress
AT beierhopet adulthumandermalfibroblastsexposedtonanosecondelectricalpulsesexhibitgeneticbiomarkersofmechanicalstress
AT barnesronalda adulthumandermalfibroblastsexposedtonanosecondelectricalpulsesexhibitgeneticbiomarkersofmechanicalstress
AT ibeybennettl adulthumandermalfibroblastsexposedtonanosecondelectricalpulsesexhibitgeneticbiomarkersofmechanicalstress