Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect

BACKGROUND AND OBJECTIVES: Balloon sizing remains the main technique for determining occluder device size for atrial septal defects (ASDs). New evidence has proposed that accurate estimation of device size could be possible without using the balloon technique. Operators have predicted the amount of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ozturk, Semi, Gurbuz, Ahmed Seyfettin, Efe, Suleyman Cagan, Yılmaz, Mehmet Fatih, Kırma, Cevat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Cardiology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5614952/
https://www.ncbi.nlm.nih.gov/pubmed/28955394
http://dx.doi.org/10.4070/kcj.2017.0073
_version_ 1783266484069335040
author Ozturk, Semi
Gurbuz, Ahmed Seyfettin
Efe, Suleyman Cagan
Yılmaz, Mehmet Fatih
Kırma, Cevat
author_facet Ozturk, Semi
Gurbuz, Ahmed Seyfettin
Efe, Suleyman Cagan
Yılmaz, Mehmet Fatih
Kırma, Cevat
author_sort Ozturk, Semi
collection PubMed
description BACKGROUND AND OBJECTIVES: Balloon sizing remains the main technique for determining occluder device size for atrial septal defects (ASDs). New evidence has proposed that accurate estimation of device size could be possible without using the balloon technique. Operators have predicted the amount of possible enlargement depending on their experiences. Thus, selection criteria have mostly relied on personal observations and experiences. The objective of this study was to determine the relationship between age, sex, defect size, and deployed device size based on the balloon technique. SUBJECTS AND METHODS: Sixty-six patients who underwent percutaneous ASD closure with a Cardi-O-Fix occluder between 2011 and 2012 were retrospectively evaluated. Patients whose maximum defect size and device size were available were included. Enlargement amount (EA) (device size−defect size) and enlargement ratio (ER) (EA/defect size) were calculated. The relationship between these 2 calculations and age, sex, and defect size were analyzed. RESULTS: EA and ER were 5.2±3.6 mm (min: 0, max: 15, median: 5) and 39.3%±31.5% (min: 0, max: 125, median: 32), respectively. EA and ER did not differ between genders (p=0.800; p=0.430). EA and ER were not correlated with maximum defect size (p=0.310; p=0.050). EA and ER showed no correlation with age (p=0.970; p=0.640). However when patients were dichomotized based on age 40, ER was significantly lower in older group (p=0.030). Unexpectedly, no difference was observed between the 2 groups in terms of EA (p=0.110). Size of deployed device had a strong correlation with defect size measured with two-dimensional (2D) transesophageal echocardiography (TEE; device size=1.1177×TEE defect size+3.5297; R=0.84; p<0.010). CONCLUSION: EA and ER did not show a significant correlation with sex and defect size in our study. Patients older than 40 had a significantly lower ER compared to younger patients. Device size was strongly correlated with defect size measured with TEE.
format Online
Article
Text
id pubmed-5614952
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Society of Cardiology
record_format MEDLINE/PubMed
spelling pubmed-56149522017-09-27 Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect Ozturk, Semi Gurbuz, Ahmed Seyfettin Efe, Suleyman Cagan Yılmaz, Mehmet Fatih Kırma, Cevat Korean Circ J Original Article BACKGROUND AND OBJECTIVES: Balloon sizing remains the main technique for determining occluder device size for atrial septal defects (ASDs). New evidence has proposed that accurate estimation of device size could be possible without using the balloon technique. Operators have predicted the amount of possible enlargement depending on their experiences. Thus, selection criteria have mostly relied on personal observations and experiences. The objective of this study was to determine the relationship between age, sex, defect size, and deployed device size based on the balloon technique. SUBJECTS AND METHODS: Sixty-six patients who underwent percutaneous ASD closure with a Cardi-O-Fix occluder between 2011 and 2012 were retrospectively evaluated. Patients whose maximum defect size and device size were available were included. Enlargement amount (EA) (device size−defect size) and enlargement ratio (ER) (EA/defect size) were calculated. The relationship between these 2 calculations and age, sex, and defect size were analyzed. RESULTS: EA and ER were 5.2±3.6 mm (min: 0, max: 15, median: 5) and 39.3%±31.5% (min: 0, max: 125, median: 32), respectively. EA and ER did not differ between genders (p=0.800; p=0.430). EA and ER were not correlated with maximum defect size (p=0.310; p=0.050). EA and ER showed no correlation with age (p=0.970; p=0.640). However when patients were dichomotized based on age 40, ER was significantly lower in older group (p=0.030). Unexpectedly, no difference was observed between the 2 groups in terms of EA (p=0.110). Size of deployed device had a strong correlation with defect size measured with two-dimensional (2D) transesophageal echocardiography (TEE; device size=1.1177×TEE defect size+3.5297; R=0.84; p<0.010). CONCLUSION: EA and ER did not show a significant correlation with sex and defect size in our study. Patients older than 40 had a significantly lower ER compared to younger patients. Device size was strongly correlated with defect size measured with TEE. The Korean Society of Cardiology 2017-09 2017-09-11 /pmc/articles/PMC5614952/ /pubmed/28955394 http://dx.doi.org/10.4070/kcj.2017.0073 Text en Copyright © 2017. The Korean Society of Cardiology https://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ozturk, Semi
Gurbuz, Ahmed Seyfettin
Efe, Suleyman Cagan
Yılmaz, Mehmet Fatih
Kırma, Cevat
Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect
title Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect
title_full Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect
title_fullStr Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect
title_full_unstemmed Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect
title_short Enlargement Ratio May Predict Device Size in Elderly Patients with Atrial Septal Defect
title_sort enlargement ratio may predict device size in elderly patients with atrial septal defect
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5614952/
https://www.ncbi.nlm.nih.gov/pubmed/28955394
http://dx.doi.org/10.4070/kcj.2017.0073
work_keys_str_mv AT ozturksemi enlargementratiomaypredictdevicesizeinelderlypatientswithatrialseptaldefect
AT gurbuzahmedseyfettin enlargementratiomaypredictdevicesizeinelderlypatientswithatrialseptaldefect
AT efesuleymancagan enlargementratiomaypredictdevicesizeinelderlypatientswithatrialseptaldefect
AT yılmazmehmetfatih enlargementratiomaypredictdevicesizeinelderlypatientswithatrialseptaldefect
AT kırmacevat enlargementratiomaypredictdevicesizeinelderlypatientswithatrialseptaldefect