Cargando…
Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia
BACKGROUND: Patients usually undergo repeated X-ray examinations after their initial X-ray radiographs are rejected due to poor image quality. This subjects the patients to excess radiation exposure and extra cost.It is therefore investigating the magnitude and causes of reject is mandatory. This st...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Research and Publications Office of Jimma University
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5615031/ https://www.ncbi.nlm.nih.gov/pubmed/29217944 |
_version_ | 1783266503238352896 |
---|---|
author | Zewdu, Mesfin Kadir, Elias Berhane, Melkamu |
author_facet | Zewdu, Mesfin Kadir, Elias Berhane, Melkamu |
author_sort | Zewdu, Mesfin |
collection | PubMed |
description | BACKGROUND: Patients usually undergo repeated X-ray examinations after their initial X-ray radiographs are rejected due to poor image quality. This subjects the patients to excess radiation exposure and extra cost.It is therefore investigating the magnitude and causes of reject is mandatory. This study aimed to assess the reject rate of X-ray films and its economic implication in order to obtain information for further recommendations on image quality, cost and radiation exposure. METHOD: A cross-sectional study approaches was employed. Reject rate was measured for two x-rays in the department across all plain x-ray films examinations using a structured format on which relevant data for reject were recorded by investigators. The results were then collected and entered into a database for analysis. RESULT: Reject rate and cause of reject were measured across all plane x-ray examinations for the hospital. From a total of 6563 exposed films, 16.85% were rejected. This leads to economic waste of 24,721.99 ETB, or 17.8% of a total cost in 4month period and increase in radiation dose to both patients and staff. CONCLUSION: The findings from this study show that both the overall reject rate and individual reject rate were higher than the accepted range which could be due to machine fault, operator's technical limitations, or absence of quality control program in the department. We recommend that regular quality assurance and quality control procedure which are well documented should be established in the department. |
format | Online Article Text |
id | pubmed-5615031 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Research and Publications Office of Jimma University |
record_format | MEDLINE/PubMed |
spelling | pubmed-56150312017-12-07 Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia Zewdu, Mesfin Kadir, Elias Berhane, Melkamu Ethiop J Health Sci Original Article BACKGROUND: Patients usually undergo repeated X-ray examinations after their initial X-ray radiographs are rejected due to poor image quality. This subjects the patients to excess radiation exposure and extra cost.It is therefore investigating the magnitude and causes of reject is mandatory. This study aimed to assess the reject rate of X-ray films and its economic implication in order to obtain information for further recommendations on image quality, cost and radiation exposure. METHOD: A cross-sectional study approaches was employed. Reject rate was measured for two x-rays in the department across all plain x-ray films examinations using a structured format on which relevant data for reject were recorded by investigators. The results were then collected and entered into a database for analysis. RESULT: Reject rate and cause of reject were measured across all plane x-ray examinations for the hospital. From a total of 6563 exposed films, 16.85% were rejected. This leads to economic waste of 24,721.99 ETB, or 17.8% of a total cost in 4month period and increase in radiation dose to both patients and staff. CONCLUSION: The findings from this study show that both the overall reject rate and individual reject rate were higher than the accepted range which could be due to machine fault, operator's technical limitations, or absence of quality control program in the department. We recommend that regular quality assurance and quality control procedure which are well documented should be established in the department. Research and Publications Office of Jimma University 2017-07 /pmc/articles/PMC5615031/ /pubmed/29217944 Text en Copyright © 2017 Stanley C.O. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Original Article Zewdu, Mesfin Kadir, Elias Berhane, Melkamu Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia |
title | Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia |
title_full | Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia |
title_fullStr | Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia |
title_full_unstemmed | Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia |
title_short | Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia |
title_sort | analysis and economic implication of x-ray film reject in diagnostic radiology department of jimma university specialized hospital, southwest ethiopia |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5615031/ https://www.ncbi.nlm.nih.gov/pubmed/29217944 |
work_keys_str_mv | AT zewdumesfin analysisandeconomicimplicationofxrayfilmrejectindiagnosticradiologydepartmentofjimmauniversityspecializedhospitalsouthwestethiopia AT kadirelias analysisandeconomicimplicationofxrayfilmrejectindiagnosticradiologydepartmentofjimmauniversityspecializedhospitalsouthwestethiopia AT berhanemelkamu analysisandeconomicimplicationofxrayfilmrejectindiagnosticradiologydepartmentofjimmauniversityspecializedhospitalsouthwestethiopia |