Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia

BACKGROUND: Patients usually undergo repeated X-ray examinations after their initial X-ray radiographs are rejected due to poor image quality. This subjects the patients to excess radiation exposure and extra cost.It is therefore investigating the magnitude and causes of reject is mandatory. This st...

Descripción completa

Detalles Bibliográficos
Autores principales: Zewdu, Mesfin, Kadir, Elias, Berhane, Melkamu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Research and Publications Office of Jimma University 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5615031/
https://www.ncbi.nlm.nih.gov/pubmed/29217944
_version_ 1783266503238352896
author Zewdu, Mesfin
Kadir, Elias
Berhane, Melkamu
author_facet Zewdu, Mesfin
Kadir, Elias
Berhane, Melkamu
author_sort Zewdu, Mesfin
collection PubMed
description BACKGROUND: Patients usually undergo repeated X-ray examinations after their initial X-ray radiographs are rejected due to poor image quality. This subjects the patients to excess radiation exposure and extra cost.It is therefore investigating the magnitude and causes of reject is mandatory. This study aimed to assess the reject rate of X-ray films and its economic implication in order to obtain information for further recommendations on image quality, cost and radiation exposure. METHOD: A cross-sectional study approaches was employed. Reject rate was measured for two x-rays in the department across all plain x-ray films examinations using a structured format on which relevant data for reject were recorded by investigators. The results were then collected and entered into a database for analysis. RESULT: Reject rate and cause of reject were measured across all plane x-ray examinations for the hospital. From a total of 6563 exposed films, 16.85% were rejected. This leads to economic waste of 24,721.99 ETB, or 17.8% of a total cost in 4month period and increase in radiation dose to both patients and staff. CONCLUSION: The findings from this study show that both the overall reject rate and individual reject rate were higher than the accepted range which could be due to machine fault, operator's technical limitations, or absence of quality control program in the department. We recommend that regular quality assurance and quality control procedure which are well documented should be established in the department.
format Online
Article
Text
id pubmed-5615031
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Research and Publications Office of Jimma University
record_format MEDLINE/PubMed
spelling pubmed-56150312017-12-07 Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia Zewdu, Mesfin Kadir, Elias Berhane, Melkamu Ethiop J Health Sci Original Article BACKGROUND: Patients usually undergo repeated X-ray examinations after their initial X-ray radiographs are rejected due to poor image quality. This subjects the patients to excess radiation exposure and extra cost.It is therefore investigating the magnitude and causes of reject is mandatory. This study aimed to assess the reject rate of X-ray films and its economic implication in order to obtain information for further recommendations on image quality, cost and radiation exposure. METHOD: A cross-sectional study approaches was employed. Reject rate was measured for two x-rays in the department across all plain x-ray films examinations using a structured format on which relevant data for reject were recorded by investigators. The results were then collected and entered into a database for analysis. RESULT: Reject rate and cause of reject were measured across all plane x-ray examinations for the hospital. From a total of 6563 exposed films, 16.85% were rejected. This leads to economic waste of 24,721.99 ETB, or 17.8% of a total cost in 4month period and increase in radiation dose to both patients and staff. CONCLUSION: The findings from this study show that both the overall reject rate and individual reject rate were higher than the accepted range which could be due to machine fault, operator's technical limitations, or absence of quality control program in the department. We recommend that regular quality assurance and quality control procedure which are well documented should be established in the department. Research and Publications Office of Jimma University 2017-07 /pmc/articles/PMC5615031/ /pubmed/29217944 Text en Copyright © 2017 Stanley C.O. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Original Article
Zewdu, Mesfin
Kadir, Elias
Berhane, Melkamu
Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia
title Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia
title_full Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia
title_fullStr Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia
title_full_unstemmed Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia
title_short Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia
title_sort analysis and economic implication of x-ray film reject in diagnostic radiology department of jimma university specialized hospital, southwest ethiopia
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5615031/
https://www.ncbi.nlm.nih.gov/pubmed/29217944
work_keys_str_mv AT zewdumesfin analysisandeconomicimplicationofxrayfilmrejectindiagnosticradiologydepartmentofjimmauniversityspecializedhospitalsouthwestethiopia
AT kadirelias analysisandeconomicimplicationofxrayfilmrejectindiagnosticradiologydepartmentofjimmauniversityspecializedhospitalsouthwestethiopia
AT berhanemelkamu analysisandeconomicimplicationofxrayfilmrejectindiagnosticradiologydepartmentofjimmauniversityspecializedhospitalsouthwestethiopia