Cargando…

A new clinical test for sensorimotor function of the hand – development and preliminary validation

BACKGROUND: Sensorimotor disturbances of the hand such as altered neuromuscular control and reduced proprioception have been reported for various musculoskeletal disorders. This can have major impact on daily activities such as dressing, cooking and manual work, especially when involving high demand...

Descripción completa

Detalles Bibliográficos
Autores principales: Röijezon, Ulrik, Faleij, Ragnar, Karvelis, Petros, Georgoulas, George, Nikolakopoulos, George
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5615462/
https://www.ncbi.nlm.nih.gov/pubmed/28950843
http://dx.doi.org/10.1186/s12891-017-1764-1
_version_ 1783266590779768832
author Röijezon, Ulrik
Faleij, Ragnar
Karvelis, Petros
Georgoulas, George
Nikolakopoulos, George
author_facet Röijezon, Ulrik
Faleij, Ragnar
Karvelis, Petros
Georgoulas, George
Nikolakopoulos, George
author_sort Röijezon, Ulrik
collection PubMed
description BACKGROUND: Sensorimotor disturbances of the hand such as altered neuromuscular control and reduced proprioception have been reported for various musculoskeletal disorders. This can have major impact on daily activities such as dressing, cooking and manual work, especially when involving high demands on precision and therefore needs to be considered in the assessment and rehabilitation of hand disorders. There is however a lack of feasible and accurate objective methods for the assessment of movement behavior, including proprioception tests, of the hand in the clinic today. The objective of this observational cross- sectional study was to develop and conduct preliminary validation testing of a new method for clinical assessment of movement sense of the wrist using a laser pointer and an automatic scoring system of test results. METHODS: Fifty physiotherapists performed a tracking task with a hand-held laser pointer by following a zig-zag pattern as accurately as possible. The task was performed with left and right hand in both left and right directions, with three trials for each hand movement. Each trial was video recorded and analysed with a specifically tailored image processing pipeline for automatic quantification of the test. The main outcome variable was Acuity, calculated as the percent of the time the laser dot was on the target line during the trial. RESULTS: The results showed a significantly better Acuity for the dominant compared to non-dominant hand. Participants with right hand pain within the last 12 months had a significantly reduced acuity (p < 0.05), and although not significant there was also a similar trend for reduced Acuity also for participants with left hand pain. Furthermore, there was a clear negative correlation between Acuity and Speed indicating a speed-accuracy trade off commonly found in manual tasks. The repeatability of the test showed acceptable intra class correlation (ICC(2.1)) values (0.68-0.81) and standard error of measurement values ranging between 5.0–6.3 for Acuity. CONCLUSIONS: The initial results suggest that the test may be a valid and feasible test for assessment of the movement sense of the hand. Future research should include assessments on different patient groups and reliability evaluations over time and between testers.
format Online
Article
Text
id pubmed-5615462
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-56154622017-09-28 A new clinical test for sensorimotor function of the hand – development and preliminary validation Röijezon, Ulrik Faleij, Ragnar Karvelis, Petros Georgoulas, George Nikolakopoulos, George BMC Musculoskelet Disord Research Article BACKGROUND: Sensorimotor disturbances of the hand such as altered neuromuscular control and reduced proprioception have been reported for various musculoskeletal disorders. This can have major impact on daily activities such as dressing, cooking and manual work, especially when involving high demands on precision and therefore needs to be considered in the assessment and rehabilitation of hand disorders. There is however a lack of feasible and accurate objective methods for the assessment of movement behavior, including proprioception tests, of the hand in the clinic today. The objective of this observational cross- sectional study was to develop and conduct preliminary validation testing of a new method for clinical assessment of movement sense of the wrist using a laser pointer and an automatic scoring system of test results. METHODS: Fifty physiotherapists performed a tracking task with a hand-held laser pointer by following a zig-zag pattern as accurately as possible. The task was performed with left and right hand in both left and right directions, with three trials for each hand movement. Each trial was video recorded and analysed with a specifically tailored image processing pipeline for automatic quantification of the test. The main outcome variable was Acuity, calculated as the percent of the time the laser dot was on the target line during the trial. RESULTS: The results showed a significantly better Acuity for the dominant compared to non-dominant hand. Participants with right hand pain within the last 12 months had a significantly reduced acuity (p < 0.05), and although not significant there was also a similar trend for reduced Acuity also for participants with left hand pain. Furthermore, there was a clear negative correlation between Acuity and Speed indicating a speed-accuracy trade off commonly found in manual tasks. The repeatability of the test showed acceptable intra class correlation (ICC(2.1)) values (0.68-0.81) and standard error of measurement values ranging between 5.0–6.3 for Acuity. CONCLUSIONS: The initial results suggest that the test may be a valid and feasible test for assessment of the movement sense of the hand. Future research should include assessments on different patient groups and reliability evaluations over time and between testers. BioMed Central 2017-09-26 /pmc/articles/PMC5615462/ /pubmed/28950843 http://dx.doi.org/10.1186/s12891-017-1764-1 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Röijezon, Ulrik
Faleij, Ragnar
Karvelis, Petros
Georgoulas, George
Nikolakopoulos, George
A new clinical test for sensorimotor function of the hand – development and preliminary validation
title A new clinical test for sensorimotor function of the hand – development and preliminary validation
title_full A new clinical test for sensorimotor function of the hand – development and preliminary validation
title_fullStr A new clinical test for sensorimotor function of the hand – development and preliminary validation
title_full_unstemmed A new clinical test for sensorimotor function of the hand – development and preliminary validation
title_short A new clinical test for sensorimotor function of the hand – development and preliminary validation
title_sort new clinical test for sensorimotor function of the hand – development and preliminary validation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5615462/
https://www.ncbi.nlm.nih.gov/pubmed/28950843
http://dx.doi.org/10.1186/s12891-017-1764-1
work_keys_str_mv AT roijezonulrik anewclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation
AT faleijragnar anewclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation
AT karvelispetros anewclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation
AT georgoulasgeorge anewclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation
AT nikolakopoulosgeorge anewclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation
AT roijezonulrik newclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation
AT faleijragnar newclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation
AT karvelispetros newclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation
AT georgoulasgeorge newclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation
AT nikolakopoulosgeorge newclinicaltestforsensorimotorfunctionofthehanddevelopmentandpreliminaryvalidation