Cargando…

Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma

PURPOSE: Our preferred treatment for juxtapapillary choroidal melanoma is stereotactic radiotherapy. We aim to describe our immobilization system and quantify its reproducibility. MATERIALS AND METHODS: Patients were identified in our radiosurgery database. Patients were imaged at computed tomograph...

Descripción completa

Detalles Bibliográficos
Autores principales: Iskanderani, Omar, Béliveau-Nadeau, Dominique, Doucet, Robert, Coulombe, Geneviève, Pascale, Deborah, Roberge, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5616051/
https://www.ncbi.nlm.nih.gov/pubmed/28168935
http://dx.doi.org/10.1177/1533034617690979
_version_ 1783266715957723136
author Iskanderani, Omar
Béliveau-Nadeau, Dominique
Doucet, Robert
Coulombe, Geneviève
Pascale, Deborah
Roberge, David
author_facet Iskanderani, Omar
Béliveau-Nadeau, Dominique
Doucet, Robert
Coulombe, Geneviève
Pascale, Deborah
Roberge, David
author_sort Iskanderani, Omar
collection PubMed
description PURPOSE: Our preferred treatment for juxtapapillary choroidal melanoma is stereotactic radiotherapy. We aim to describe our immobilization system and quantify its reproducibility. MATERIALS AND METHODS: Patients were identified in our radiosurgery database. Patients were imaged at computed tomography simulator with an in-house system which allows visual monitoring of the eye as the patient fixates a small target. All patients were reimaged at least once prior to and/or during radiotherapy. The patients were treated on the CyberKnife system, 60 Gy in 10 daily fractions, using skull tracking in conjunction with our visual monitoring system. In order to quantify the reproducibility of the eye immobilization system, computed tomography scans were coregistered using rigid 6-dimensional skull registration. Using the coregistered scans, x, y, and z displacements of the lens/optic nerve insertion were measured. From these displacements, 3-dimensional vectors were calculated. RESULTS: Thirty-four patients were treated from October 2010 to September 2015. Thirty-nine coregistrations were performed using 73 scans (2-3 scans per patient). The mean displacements of lens and optic nerve insertion were 0.1 and 0.0 mm. The median 3-dimensional displacements (absolute value) of lens and nerve insertion were 0.8 and 0.7 mm (standard deviation: 0.5 and 0.6 mm). Ninety-eight percent of 3-dimensional displacements were below 2 mm (maximum 2.4 mm). The calculated planning target volume (PTV) margins were 0.8, 1.4, and 1.5 mm in the anterior–posterior, craniocaudal, and right–left axes, respectively. Following this analysis, no further changes have been applied to our planning margin of 2 to 2.5 mm as it is also meant to account for uncertainties in magnetic resonance imaging to computed tomography registration, skull tracking, and also contouring variability. CONCLUSION: We have found our stereotactic eye immobilization system to be highly reproducible (<1 mm) and free of systematic error.
format Online
Article
Text
id pubmed-5616051
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-56160512017-10-03 Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma Iskanderani, Omar Béliveau-Nadeau, Dominique Doucet, Robert Coulombe, Geneviève Pascale, Deborah Roberge, David Technol Cancer Res Treat Articles PURPOSE: Our preferred treatment for juxtapapillary choroidal melanoma is stereotactic radiotherapy. We aim to describe our immobilization system and quantify its reproducibility. MATERIALS AND METHODS: Patients were identified in our radiosurgery database. Patients were imaged at computed tomography simulator with an in-house system which allows visual monitoring of the eye as the patient fixates a small target. All patients were reimaged at least once prior to and/or during radiotherapy. The patients were treated on the CyberKnife system, 60 Gy in 10 daily fractions, using skull tracking in conjunction with our visual monitoring system. In order to quantify the reproducibility of the eye immobilization system, computed tomography scans were coregistered using rigid 6-dimensional skull registration. Using the coregistered scans, x, y, and z displacements of the lens/optic nerve insertion were measured. From these displacements, 3-dimensional vectors were calculated. RESULTS: Thirty-four patients were treated from October 2010 to September 2015. Thirty-nine coregistrations were performed using 73 scans (2-3 scans per patient). The mean displacements of lens and optic nerve insertion were 0.1 and 0.0 mm. The median 3-dimensional displacements (absolute value) of lens and nerve insertion were 0.8 and 0.7 mm (standard deviation: 0.5 and 0.6 mm). Ninety-eight percent of 3-dimensional displacements were below 2 mm (maximum 2.4 mm). The calculated planning target volume (PTV) margins were 0.8, 1.4, and 1.5 mm in the anterior–posterior, craniocaudal, and right–left axes, respectively. Following this analysis, no further changes have been applied to our planning margin of 2 to 2.5 mm as it is also meant to account for uncertainties in magnetic resonance imaging to computed tomography registration, skull tracking, and also contouring variability. CONCLUSION: We have found our stereotactic eye immobilization system to be highly reproducible (<1 mm) and free of systematic error. SAGE Publications 2017-02-07 2017-06 /pmc/articles/PMC5616051/ /pubmed/28168935 http://dx.doi.org/10.1177/1533034617690979 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Articles
Iskanderani, Omar
Béliveau-Nadeau, Dominique
Doucet, Robert
Coulombe, Geneviève
Pascale, Deborah
Roberge, David
Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma
title Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma
title_full Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma
title_fullStr Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma
title_full_unstemmed Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma
title_short Reproducibility of a Noninvasive System for Eye Positioning and Monitoring in Stereotactic Radiotherapy of Ocular Melanoma
title_sort reproducibility of a noninvasive system for eye positioning and monitoring in stereotactic radiotherapy of ocular melanoma
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5616051/
https://www.ncbi.nlm.nih.gov/pubmed/28168935
http://dx.doi.org/10.1177/1533034617690979
work_keys_str_mv AT iskanderaniomar reproducibilityofanoninvasivesystemforeyepositioningandmonitoringinstereotacticradiotherapyofocularmelanoma
AT beliveaunadeaudominique reproducibilityofanoninvasivesystemforeyepositioningandmonitoringinstereotacticradiotherapyofocularmelanoma
AT doucetrobert reproducibilityofanoninvasivesystemforeyepositioningandmonitoringinstereotacticradiotherapyofocularmelanoma
AT coulombegenevieve reproducibilityofanoninvasivesystemforeyepositioningandmonitoringinstereotacticradiotherapyofocularmelanoma
AT pascaledeborah reproducibilityofanoninvasivesystemforeyepositioningandmonitoringinstereotacticradiotherapyofocularmelanoma
AT robergedavid reproducibilityofanoninvasivesystemforeyepositioningandmonitoringinstereotacticradiotherapyofocularmelanoma