Cargando…
Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage
The platelet-rich fibrin–like matrix (PRFM) is usually prepared onsite and immediately used for regenerative therapy. Nonetheless, to meet the clinical necessity of preserving the PRFM without quality deterioration, we developed a method for preparation of PRFMs from short-term-stored whole blood (W...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5618315/ https://www.ncbi.nlm.nih.gov/pubmed/28926988 http://dx.doi.org/10.3390/biomedicines5030057 |
_version_ | 1783267158696919040 |
---|---|
author | Kawabata, Hideo Isobe, Kazushige Watanabe, Taisuke Okudera, Toshimitsu Nakamura, Masayuki Suzuki, Masashi Ryu, Jietsu Kitamura, Yutaka Okudera, Hajime Okuda, Kazuhiro Nakata, Koh Kawase, Tomoyuki |
author_facet | Kawabata, Hideo Isobe, Kazushige Watanabe, Taisuke Okudera, Toshimitsu Nakamura, Masayuki Suzuki, Masashi Ryu, Jietsu Kitamura, Yutaka Okudera, Hajime Okuda, Kazuhiro Nakata, Koh Kawase, Tomoyuki |
author_sort | Kawabata, Hideo |
collection | PubMed |
description | The platelet-rich fibrin–like matrix (PRFM) is usually prepared onsite and immediately used for regenerative therapy. Nonetheless, to meet the clinical necessity of preserving the PRFM without quality deterioration, we developed a method for preparation of PRFMs from short-term-stored whole blood (WB) samples. In this study, to evaluate the practical expiration date of storage, we extended the storage time of WB samples from 2 to 7 days and assessed the quality of the resulting PRFMs. WB samples collected with acid-citrate-dextrose were stored with gentle agitation at ambient temperature. To prepare PRFMs, the stored WB samples were mixed with CaCl(2) in glass tubes and centrifuged. Fibrin fiber networks, CD41 and CD62P expression, and Platelet Derived Growth Factor-BB (PDGF-BB) levels were examined by scanning electron microscopy (SEM), flow cytometry, and an Enzyme-Linked ImmunoSorbent Assay (ELISA), respectively. Long-term storage had no significant effect on either blood cell counts or platelet functions tested. The resulting PRFMs were visually identical to freshly prepared ones. PDGF-BB levels did not markedly decrease in a time-dependent manner. However, fibrin fibers gradually became thinner after storage. Although the coagulation activity may diminish, we propose that PRFMs can be prepared—without evident loss of quality—from WB samples stored for up to 7 days by our previously developed method. |
format | Online Article Text |
id | pubmed-5618315 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-56183152017-09-29 Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage Kawabata, Hideo Isobe, Kazushige Watanabe, Taisuke Okudera, Toshimitsu Nakamura, Masayuki Suzuki, Masashi Ryu, Jietsu Kitamura, Yutaka Okudera, Hajime Okuda, Kazuhiro Nakata, Koh Kawase, Tomoyuki Biomedicines Article The platelet-rich fibrin–like matrix (PRFM) is usually prepared onsite and immediately used for regenerative therapy. Nonetheless, to meet the clinical necessity of preserving the PRFM without quality deterioration, we developed a method for preparation of PRFMs from short-term-stored whole blood (WB) samples. In this study, to evaluate the practical expiration date of storage, we extended the storage time of WB samples from 2 to 7 days and assessed the quality of the resulting PRFMs. WB samples collected with acid-citrate-dextrose were stored with gentle agitation at ambient temperature. To prepare PRFMs, the stored WB samples were mixed with CaCl(2) in glass tubes and centrifuged. Fibrin fiber networks, CD41 and CD62P expression, and Platelet Derived Growth Factor-BB (PDGF-BB) levels were examined by scanning electron microscopy (SEM), flow cytometry, and an Enzyme-Linked ImmunoSorbent Assay (ELISA), respectively. Long-term storage had no significant effect on either blood cell counts or platelet functions tested. The resulting PRFMs were visually identical to freshly prepared ones. PDGF-BB levels did not markedly decrease in a time-dependent manner. However, fibrin fibers gradually became thinner after storage. Although the coagulation activity may diminish, we propose that PRFMs can be prepared—without evident loss of quality—from WB samples stored for up to 7 days by our previously developed method. MDPI 2017-09-18 /pmc/articles/PMC5618315/ /pubmed/28926988 http://dx.doi.org/10.3390/biomedicines5030057 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kawabata, Hideo Isobe, Kazushige Watanabe, Taisuke Okudera, Toshimitsu Nakamura, Masayuki Suzuki, Masashi Ryu, Jietsu Kitamura, Yutaka Okudera, Hajime Okuda, Kazuhiro Nakata, Koh Kawase, Tomoyuki Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage |
title | Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage |
title_full | Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage |
title_fullStr | Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage |
title_full_unstemmed | Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage |
title_short | Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage |
title_sort | quality assessment of platelet-rich fibrin-like matrix prepared from whole blood samples after extended storage |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5618315/ https://www.ncbi.nlm.nih.gov/pubmed/28926988 http://dx.doi.org/10.3390/biomedicines5030057 |
work_keys_str_mv | AT kawabatahideo qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT isobekazushige qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT watanabetaisuke qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT okuderatoshimitsu qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT nakamuramasayuki qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT suzukimasashi qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT ryujietsu qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT kitamurayutaka qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT okuderahajime qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT okudakazuhiro qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT nakatakoh qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage AT kawasetomoyuki qualityassessmentofplateletrichfibrinlikematrixpreparedfromwholebloodsamplesafterextendedstorage |